Clamp pincer CP 10 / CP 20 / CC 20
5 Use of the clamp pincer
Issue 06.19
08902961
5-29
The following description serves as an example for ear clamps. You can find more detailed information on
OETIKER products from your OETIKER contact person.
Requirements:
– Closure force and closure force holding time
have been set using the PC software and
uploaded to the clamp pincer.
– The clamp pincer has been calibrated.
1. Insert the ear of an OETIKER clamp (Fig. 14/1)
into the clamping range of the pincer head
(Fig. 14/2).
Fig. 14: Insert clamp
2. Press the START button (Fig. 15/3) and hold it
down.
Fig. 15: Start closure
The closure process is triggered and the clamp
(Fig. 16/4) closes.
On reaching predefined parameter values the
pincer jaws are opened.
3. Release the START button.
Fig. 16: The clamp is closed
INFO
Closure is performed using the closure data loaded by the PC software.
A further closure operation can now be performed.