PITCHER 

Maximum value is 99 for pitcher number & 99 for pitch count. (Values will be saved in memory when going 

between half innings) 

 

 

To set a pitcher’s value: 

o

 

Press PITCHER, enter the pitchers number on the numeric keypad and press ENTER 

o

 

Enter the pitcher’s pitch count on the numeric keypad and press ENTER 

 

 

To increment a pitcher’s pitch count: 

o

 

Press PITCH COUNT +1 

 

PITCH SPEED 

Pitch Speed values normally come from an external pitch speed gun attached to controller, but can also be 

manually entered. 

 

 

Maximum value: 199. 

 

To manually set a pitch speed: 

o

 

Press PITCH SPEED. 

o

 

Enter the pitch speed on the numeric keypad. 

o

 

Press ENTER 

Scoreboard display will show this value for the pre-configured time. This amount if time can be 

set up in 

CONFIGURATION OPTION #2 – Sport (specific sport settings). It is set to 20 seconds by 

default.

 

PITCH TIMER 

 

 

To open the Pitch Timer menu: 

o

 

Press the PITCH TIMER button 

 

 

Содержание ISC-9000

Страница 1: ...INTELLIGENT SCOREBOARD CONTROLLER MODEL ISC 9000 USER MANUAL...

Страница 2: ...0 OUT 6 Game Port 1 Labeled GAME OUT 6 Game Port 2 Labeled GAME OUT 6 USB 6 Ethernet WI FI 6 OES Coax 6 OPERATING INSTRUCTIONS 7 GENERAL NOTES 7 POWER OFF ON 7 POWER ON SEQUENCE 8 SPLASH SCEEN Display...

Страница 3: ...ION 8 ISC Comm Ports RECEIVE Communication ports 16 CONFIGURATION OPTION 9 RF Radio frequence channels 17 SETTING RADIO CHANNEL IN CONTROLLER 17 SETTING RADIO CHANNELS FOR SCOREBOARDS 17 CONFIGURATION...

Страница 4: ...nus 32 Possession POSS Serving 32 Field 32 Sets 33 Volleyball 33 Tennis 33 Tie Breaker 33 Corner Kicks 34 Match 34 Team Points 34 Advantage 35 Segment Timer 35 FAQ 37 How to Setup Time of Day 37 How t...

Страница 5: ...f experiencing wireless communication issues placing the antenna vertically may help FEATURES Standard Features Microprocessor and Quartz Crystal based providing timing accuracy Battery Backed Memory...

Страница 6: ...d 2021 10 21 Page 5 of 44 HARDWARE FRONT PANEL BACK PANEL See next page for interface details 5 1 GRAPHIC BACKLIT LCD GAME TIME CONTROL Manual Horn Button Time running Indicator LED RUN STOP Buttons C...

Страница 7: ...r RS485 2 Wire Mating Connectors OES CN138F and CN139B Pin out Pin 3 RS Pin 4 RS Game Port 1 Labeled GAME OUT XLR 4 pin connector RS485 2 wire Mating Connector OES CN137D Pin out Pin 3 RS Pin 4 RS Gam...

Страница 8: ...key press will put the cursor on the value the second key press will increment decrement the value by 1 and turn the cursor off The only value that will be decremented is TOL any other values will all...

Страница 9: ...seconds Shows program revision and date Shows controller operation mode WIRELESS COMMUNICATION Displays up to 60 seconds Press ENTER button to use confirm MEMORY RECALL Displays up to 60 seconds Pres...

Страница 10: ...lowing screen appears Enter password 5833 on numeric keypad and press ENTER If an incorrect password is entered the unit will return to game mode USER CONFIGURATION MENU Use numeric keypad to make sel...

Страница 11: ...unt up or down UP TIME LIMIT The time at which the clock will stop and sound the horn BLANK PLAY CLOCK WHEN ZERO Play clock blanks when game time is zero After this a game settings screen may appear f...

Страница 12: ...S SECS Selects the SHOT CLOCK time to start displaying tenths of seconds SHIFT SEG Enables the SHIFT TIMER or the SEGMENT TIMER FOOTBALL MAX DOWNS Set the maximum number of downs CENTER FIELD Set the...

Страница 13: ...to show either match or advantage time Only displayed on specific scoreboards SOCCER AUTO SAVES Select if the SAVES is manually entered or automatically calculated The automatic calculation is the dif...

Страница 14: ...Seconds that the pitch speed will be displayed on the scoreboard 1 60sec PITCH SPEED OFFSET This will adjust the speed of the speed received from the radar gun PITCH TIMER TIMER SETTING 1 Seconds tha...

Страница 15: ...Use the keypad to select the day month and year pressing ENTER for each field Once the year is accepted you will be taken back to game mode Time of day will be sent to clocks when all values are set...

Страница 16: ...n on goal light to the left of the operator o I P R GOALLIGHT Turn on goal light to the right of the operator o I P ADV HOME Controls home advantage time o I P ADV GUEST Controls guest advantage time...

Страница 17: ...ter editing the outputs the next screen appears to set output time lengths To set each value Enter value on the numeric keypad Press ENTER HORN is the length of horn in seconds when times reaches 0 or...

Страница 18: ...her X9 DM or X2 DM will appear CHANNEL Set desired radio channel for the control unit Press CLEAR to toggle through channels ADDRESS GROUP Set desired radio address group for the control unit X9 only...

Страница 19: ...nction can be used to setup fixed time out table for quickly starting different time out times Setting up the table will happen in this menu Function of the TIME OUTS will be covered in Intermission B...

Страница 20: ...n the horn is desired Add on times allow you to set 3 different times which can be added to the time out time This allows a time out to be extended by any of the 3 values set here Next screen On this...

Страница 21: ...ENTER o To toggle characters use the numeric alpha keypad o After one second of editing a character the cursor will go to the next character A beep will occur o You can go to the next character witho...

Страница 22: ...00 can be entered by pressing CLEAR or the current hundredths setting can be accepted by hitting ENTER If GAME TIME is pressed when time is running the display will show the screen with game time but...

Страница 23: ...e game time RUN and STOP buttons to count down the INT MODE timer When the timer reaches zero the horn will sound While in INT MODE press INT MODE to exit back to regular game mode Time out table Whil...

Страница 24: ...d then clear for next game Note See Game Time for automatic incrementing of the period value SHIFT To enable disable see CONFIGURATION OPTION 2 Sport specific sport settings in the setup menu This tim...

Страница 25: ...ry reset value o SET B is the secondary reset value o SET C is an extra reset time value o The time in the PLAY TIMER box is the current time on the shot clock It can be set to a temporary time if nec...

Страница 26: ...n input is needed for football to run the shot clock To blank Play Clocks or Shot Clocks o Set reset select to BLANK o Press PLAY TIMER RESET or SHOT TIMER RESET INNING Maximum value is 40 To set inni...

Страница 27: ...2 when the active 1 2 penalties expire This can be changed in CONFIGURATION OPTION 2 Sport specific sport settings The maximum Player Number is 99 The maximum Penalty Minutes is 99 but the message pr...

Страница 28: ...eature o Needs to be enabled in CONFIGURATION OPTION 2 Sport specific sport settings o Penalty time stop run is controlled with the keypad Game time must be running for penalty time to run o To toggle...

Страница 29: ...HOME TOL or GUEST TOL o Press ENTER o Press the same HOME TOL or GUEST TOL again If automatic AUTO TIMEOUT TIMER is selected in Configuration Option 0 Time Outs the time out time will begin to run as...

Страница 30: ...oreboard Soccer Maximum value is 99 To set a team s Penalty o Press either HOME FOULS or GUEST FOULS o Enter value on numeric keypad o Press ENTER To increment a team s Penalty o Press either HOME FOU...

Страница 31: ...ric keypad and press ENTER To increment a pitcher s pitch count o Press PITCH COUNT 1 PITCH SPEED Pitch Speed values normally come from an external pitch speed gun attached to controller but can also...

Страница 32: ...H TIMER STOP button BATTER Maximum value is 99 for Player Number and 0 999 for Player Batting Average To set a batter s value o Press AT BAT o Enter the batter s number on numeric keypad o Press ENTER...

Страница 33: ...n DN on numeric keypad press ENTER o Enter value for yards to go YTG on numeric keypad press ENTER o Select side of the field is the ball is on Toggle HOME GUEST with the CLEAR button and ENTER to acc...

Страница 34: ...s o Use the keypad to enter scores pressing ENTER after each entry Tennis To select current SET o Press SETS 1 or SETS 1 to toggle between the 5 sets To edit SETS o Press SETS EDIT o Use the ENTER but...

Страница 35: ...eypad o Press ENTER To increment a team s Corner Kicks o Press either HOME C K or GUEST C K twice MATCH For Wrestling only Maximum value is 255 To set Match Press MATCH Enter value on numeric keypad P...

Страница 36: ...ADVANTAGE WILL NOT OPERATE PROPERLY To start a team s advantage timer o Press either START HOME ADV or START GUEST ADV To stop advantage timers o Press STOP ADV o Active Advantage time runs in sync w...

Страница 37: ...imum value is 99 o Press ENTER o Enter minutes of the timer value on numeric keypad o Press ENTER o Enter seconds of the timer value on numeric keypad o Press ENTER Maximum value is 59 minutes and 59...

Страница 38: ...L 1P7 Rev ISC9000_j12 0_1 3 Issued 2021 10 21 Page 37 of 44 FAQ HOW TO SETUP TIME OF DAY Hold the setup button until it prompts you for a password The password is 5833 the last 4 digits of our phone n...

Страница 39: ...ntinue to the day Using the CLEAR button scroll through days of the week and press ENTER to continue Use the keypad to select the day month and year pressing ENTER for each field Once the year is acce...

Страница 40: ...the last 4 digits of our phone number Select option 6 ISC Inputs Remote 1A Corresponds to remote 1 button or switch A Remote 1B Corresponds to remote 1 button or switch B Remote 2A Corresponds to remo...

Страница 41: ...side under Configuration click Network a Under the IP Settings tab ensure Obtain an IP address automatically using DHCP is selected If any changes are made click Apply 6 From the left side under Conf...

Страница 42: ...following steps are required to load system default setting in the ISC9000 controllers 1 Turn power off to the controller 2 Turn power on to the controller 3 The OES logo and information screen will a...

Страница 43: ...B Connector DB9 Female CN251A Connector DB9 Shell CN290A Cable NULL Modem AU008A Cable Controller Comm 8 8001005008 Cable Controller Comm 25 8001005025 Cable Controller Comm 50 8001005050 Electrical V...

Страница 44: ...www oes scoreboards com 1 877 652 5833 4056 Blakie Rd London ON Canada N6L 1P7 Rev ISC9000_j12 0_1 3 Issued 2021 10 21 Page 43 of 44 APPENDIX C INSERTS...

Страница 45: ...of 44 IMPORTANT INFORMATION Scoreboard Model ________________________ Scoreboard Serial Number __________________ Controller Serial Number ___________________ Channel ________________________________...

Страница 46: ...For complete engineering and technical support contact 4056 Blakie Road London Ontario Canada N6L 1P7 Telephone 519 652 5833 Fax 519 652 3795 e mail oes oes inc com Revision J12 21 OCT 21...

Отзывы: