Operation 
From production month 07/2005 on the Mobile series is equipped with an 
EMERGENCY STOP switch (2 a). In case of emergency push 
EMERGENCY STOP switch. After elimination of cause EMERGENCY 
STOP switch to be released by pulling it out, otherwise machine cannot 
be re-started. 

 

For starting the combustion engine, observe engine 
manufacturer’s instructions. 

 
 

Never disconnect starter battery when engine is running. In order 
to ease start-up of the engne, open safety/control valve (3) by 
turning the hand wheel counter-clockwise for pressure relief 
purposes. 

 

  Fully open water source, respectively dip in suction hose with 

strainer. 

 

Electric Start – Cold Engine: 

  Put choke (51) into start position/fully pull out choke (depending 

on design). 

  Turn gas pedal (49) into full load position. 

  Turn ignition key (50) clockwise into position “Start” until motor 

starts. Actuate starter for max. 10 seconds. Excessive start 
attempts may damage the starter. 

  Slowly open choke during engine warm-up in order to avoid 

dying down of the motor during load alternation. Open spray 
pistol and warm up engine at low pressure for a few minutes. 

  Afterwards, increase pressure to maximum by turning the hand 

wheel of the safety/control valve (3) clockwise. 

 

Be aware of significant recoil

. Ensure stable foothold. 

 

 

Electric Start – Hot Motor: 

 

Do not actuate choke (51). 

  Turn gas pedal (49) into 

 load position. 

  Turn ignition key (50) clockwise into position “Start” until motor starts. 

Actuate starter for max. 10 seconds. Excessive start attempts may 
damage the starter. 

  After engine has started, turn gas pedal (49) into full load position. 

  Then increase pressure to maximum by turning the hand wheel of the 

safety/control valve (3) clockwise. 

 
 

Be aware of significant recoil

. Ensure stable foothold. 

 

  Unlock and release spray pistol, bleed unit 

  Push ON/OFF switch (2).  

  Carry out cleaning task. 

 

 

 

 

 

 

Содержание M 500

Страница 1: ...High Pressure Cleaner with Combustion Engine M 400 M 500 To be read carefully before start up von Oertzen GmbH Ferdinand Harten Str 10 22949 Ammersbek Tel 49 40 604110 Fax 49 40 6041149 www oertzen g...

Страница 2: ...y Instructions pages 4 5 3 Configuration Illustration pages 6 7 4 Start up Operation Shut down pages 8 12 5 Maintenance and Care pages 13 14 6 Technical Data page 15 7 Trouble Shooting pages 16 8 Decl...

Страница 3: ...and to be made available to authorities their on request OERTZEN offers qualified service personnel to carry out safety inspections at attractive prices The packing materials plastic foil wood cardbo...

Страница 4: ...control valve is workshop set and sealed Adjustment must not be changed Machines driven by combustion engines must not be run indoors unless proper ventilation and exhaust gas evacuation are guarantee...

Страница 5: ...g brake it must be set during working During loading hoisting device to be fastened properly at jack rings Ensure balanced load The exhaust evacuation area is hot Do not touch Repair work in the high...

Страница 6: ...ps below 2 bar Downstream of the high pressure pump a locked and sealed safety control valve is installed which opens as soon as the operating pressure is exceeded by more than 20 bar and returns the...

Страница 7: ...7...

Страница 8: ...dip stick correct oil level of combustion engine dip stick Only oil qualities approved by OERTZEN to be used High pressure pump special pump oil OERTZEN OSP reduction gear special pump oil OERTZEN OSP...

Страница 9: ...maximum 8 bar 21 l min 1 water supply hose 30 l min 1 water supply hose see Technical Data Insufficient water supply will cause heavy damage on high pressure pump cavitation High Pressure Connection...

Страница 10: ...position Start until motor starts Actuate starter for max 10 seconds Excessive start attempts may damage the starter Slowly open choke during engine warm up in order to avoid dying down of the motor...

Страница 11: ...low increase to maximum capacity When pistol is closed machine is running in circulation mode If water temperature exceeds 60 C thermo valve 14 opens releases small amounts of hot water and cold water...

Страница 12: ...arranty Reduction Gearbox First oil change after 50 operating hours all further oil changes every 500 operating hours min once a year Correct oil level to be checked every day Exclusively OSP pump oil...

Страница 13: ...ree area If there is a risk of frost during storage and or transport the machine to be protected as follows 2 l of a 1 1 water frost protection liquid to be mixed in a clean vessel water connecting ho...

Страница 14: ...2 kW Fuel consumption at full load 7 7 l h 7 7 l h Tank volume 20 l 20 l Low oil level cut out standard standard Starting device battery start battery start Emergency start recoil start recoil start...

Страница 15: ...ignition switch into pos On 1 Close choke Check items under Engine stops Engine trips No fuel Low oil level Fuel filter clogged Sparking plug burnt Fill fuel tank Refill oil up to maximum Clean fuel f...

Страница 16: ...16...

Отзывы: