Operation
From production month 07/2005 on the Mobile series is equipped with an
EMERGENCY STOP switch (2 a). In case of emergency push
EMERGENCY STOP switch. After elimination of cause EMERGENCY
STOP switch to be released by pulling it out, otherwise machine cannot
be re-started.
For starting the combustion engine, observe engine
manufacturer’s instructions.
Never disconnect starter battery when engine is running. In order
to ease start-up of the engne, open safety/control valve (3) by
turning the hand wheel counter-clockwise for pressure relief
purposes.
•
Fully open water source, respectively dip in suction hose with
strainer.
Electric Start – Cold Engine:
•
Put choke (51) into start position/fully pull out choke (depending
on design).
•
Turn gas pedal (49) into full load position.
•
Turn ignition key (50) clockwise into position “Start” until motor
starts. Actuate starter for max. 10 seconds. Excessive start
attempts may damage the starter.
•
Slowly open choke during engine warm-up in order to avoid
dying down of the motor during load alternation. Open spray
pistol and warm up engine at low pressure for a few minutes.
•
Afterwards, increase pressure to maximum by turning the hand
wheel of the safety/control valve (3) clockwise.
Be aware of significant recoil
. Ensure stable foothold.
Electric Start – Hot Motor:
•
Do not actuate choke (51).
•
Turn gas pedal (49) into
load position.
•
Turn ignition key (50) clockwise into position “Start” until motor starts.
Actuate starter for max. 10 seconds. Excessive start attempts may
damage the starter.
•
After engine has started, turn gas pedal (49) into full load position.
•
Then increase pressure to maximum by turning the hand wheel of the
safety/control valve (3) clockwise.
Be aware of significant recoil
. Ensure stable foothold.
•
Unlock and release spray pistol, bleed unit
•
Push ON/OFF switch (2).
•
Carry out cleaning task.