6
7
▪
Prior to commissioning, mount the
protective cover (7) to the bracket
(9) with a screw (6).
1.3.4 Removal from a line
WARNING
Risk of burns!
Risk due to hot surfaces.
During the transport of hot pumps, hot pump media may drip.
▶
Wear the required PPE.
WARNING
Risk of getting caught
Prior to disassembly, switch off the pump drive and secure it against unau-
thorized restart.
WARNING
Risk of electric shock
Maintenance or repair of electrical components must only be performed by
qualified electricians.
▶
Switch off the pump drive prior to carrying out repair and service work.
▶
When carrying out work on the motor, it must be de-energized and se-
cured against restart.
WARNING
Leakage of liquid und/or gas under pressure!
▶
Before the pump is removed from the line/machine, make sure that all
connecting lines to the pump are depressurized and closed off.
11
Assembly Instructions, 09.22
09/2022 Released
TDD-00035234 1-051-8387
Eccentric screw pump
1 Mounting instructions