3
Operating Instructions and Parts Manual
24887
4,500 CFM 3 SPEED
EVAPORATIVE COOLER
1/18
2018 OEMTOOLS
™
ASSEMBLY INSTRUCTIONS
The OEMTOOLS
™
24887 4,500 CFM 3 Speed Evaporative Cooler is pre-
assembled. Carefully remove the Evaporative Cooler from the Box. Install
the (4) casters.
PREPARING FOR OPERATION
IMPORTANT:
Read and understand the provided safety instructions prior
to operation.
1. Before attempting to use, inspect the filter for dirt, dust or residues.
Cooling pads that have accumulated build-up will impede cooling
performance.
2. To operate effectively, position the unit in front of an open door or
window. Ensure the unit is placed on a flat, level surface with the
casters in the locked position.
3. Open another door or window to provide proper ventilation for the unit.
MANUAL FILL
1. Depress the Fill Door located on the front of the unit below the louvers
(the Fill Door features a spring lock, and will release when pressed).
2. Fill the Water Tank using a hose or bucket. Monitor water level using
the Fill Gauge.
3. Press the Fill Door closed (the spring lock with re-engage).
AUTOMATIC FILL CONNECTION
NOTE:
This unit features a float valve and automatic shut-off function.
This allows the unit to remain connected to an open water source for a
continuous flow of water. The operator may also fill the Water Tank to
capacity (or desired level) prior to running the unit, and then close the
water source.
1. Attach the provided Pigtail Adapter to the Water Inlet.
2. Connect one end of the provided Coil Hose to the Pigtail Adapter.
3. Connect the other end of the Coil Hose to a water supply. Ensure that
both connections are water tight.
OPERATING INSTRUCTIONS
1. Plug the unit into a grounded 110-120V AC outlet.
NOTE:
This Evaporative Cooler is equipped with a UL Ground Fault Circuit
Interrupter (GFCI) Plug. This UL GFCI Plug is designed to interrupt power
to the unit if current follows an unintended path. This feature is a safety
measure to reduce risk of electric shock to the operator and electrical
damage to the Evaporative Cooler. If the circuit is tripped, press the Reset
Button located on the plug head. If the Reset Button will not engage and
power is not restored, discontinue use, see the troubleshooting section for
further instruction.
2. Open the water source to fill the Water Tank. Monitor water level using
the Fill Gauge; allow the Water Tank to reach 50% capacity.
WARNING
:
Water Inlet pressure should not exceed 50 PSI. Higher
pressure may lead to product failure and property damage.
3. Switch the Power to ON.
4. Switch the Pump to ON. Allow to run for 2-3 minutes to saturate the
Cooling Pads with water.
NOTE:
The pump will automatically shut-off when the water level is low.
5. Switch the Fan to the first speed setting. Allow to run at the first speed
setting for 2-3 minutes. Increase the speed of the fan to the desired
setting: Off, Low, Medium and High.
6. To oscillate airflow, switch the Swing Setting to ON.
SHUTDOWN INSTRUCTIONS
1. Close the water source.
2. After the Water Tank has emptied, switch the Pump to OFF.
NOTE:
See Draining Instructions if the Water Tank is not empty.
3. At the end of each day of use, allow the Fan to run for about 20
minutes to dry the Cooling Pad(s).
4. Switch the Fan to OFF.
5. Switch the Power to OFF.
6. Unplug the Power Cord from the power source.
DRAINING INSTRUCTIONS
1. Turn the Power to OFF, and ensure the unit is not plugged into a power
source.
2. Move the unit outdoors or position the unit over a drain.
3. Unscrew the Drain Cap from the Drain Assembly. Allow the water to
completely drain from the Water Tank.
4. Replace the Drain Cap to the Drain Assembly.
STORAGE
Store the Evaporative Cooler in an upright position and in a clean, dry
area. DO NOT store near flammable items or open flames.
DISPOSAL
At the end of the useful life of the OEMTOOLS
™
24887 4,500 CFM 3
Speed Evaporative Cooler, dispose of the components in accordance with
all federal, state and local regulations.
PRODUCT MAINTENANCE
WARNING
:
Unplug this unit from the power source before
performing product maintenance.
WARNING
:
DO NOT use water to clean the Fan, Electrical
Components or Control Panel.
WARNING
:
DO NOT attempt to perform product maintenance on
the motor or electrical systems. If there is any doubt that this unit can
perform safely, immediately discontinue use and contact customer
service.
1. Dirt and debris will settle at the bottom of the Water Tank. To optimize
performance, it is recommended that the Water Tank is cleaned
monthly.
2. To maintain high air quality, it is recommended that the water is
flushed from the Water Tank daily.
3. Inspect the cooling pads prior to each use. If dirt, debris or build-up is
present, remove the cooling pad and gently wipe clean. Replace the
cooling pad to the unit.
NOTE:
The Cooling Pads are constructed with a special resin impregnated
craft paper specifically designed for this evaporative cooler. If the unit
is used in accordance with this product manual, and the cooling pads
are properly maintained, they will last several years (under normal
circumstances).
PRODUCT LAYOUT
ITEM DESCRIPTION
QTY. ITEM DESCRIPTION
QTY.
A
Control Panel
1
I
Fill Gauge
1
B
Oscillating Blades
11
J
Cooling Pads*
2
C
Fan
1
K
GFCI Plug*
1
D
Vertically Adjustable Louvers 11
L
Water Inlet*
1
E
Manual Fill Door
1
M
Pigtail Adapter*
1
F
Water Tank
1
N
Coil Hose*
1
G
Swivel Caster
2
O
Water Drain Assembly* 1
H
Locking Caster
2
G
F
E
D
C
B
A
I
H
*Not Shown