Settings 2nd level (Cover open)
Incorrect changes to the settings may cause the heating system to
malfunction or shorten its life.
Sym-
bol
Function to be set
Fac
tor
y
set
ting
s
Sett
ing
range
Ba
sic
adjus
tmen
t
Ad
ju
stme
nt
Un
it
"Setting the time (clock)"; page 15
pre-
sent *
-
h/m
pre-
sent *
until
2079
M/T/J
"Setting the room temperature heating
mode"; page 16
20
10
÷
30
°C
"Setting the room temperature for night
reduction heating mode"; page 17
15
5
÷
20
°C
"Setting the warm water temperature";
page 17
55
10
÷
70
°C
"Adjusting the heating curve"; page 18
1.2
0.0
÷
5.0
-
"Setting the maximum supply tempe-
rature"; page 19
70
10
÷
90
°C
"Setting the heating limit (summer/win-
ter)"; page 19
18
0
÷
40
°C
Sym-
bol
Function to be set
Unit
"Displaying temperatures and values"; page 21
°C
"The standard clock programs (factory settings)"; page 23
"Setting the clock programs for heating/D.H.W."; page 26
-
"Setting an individual D.H.W. clock program P1"; page 28
-
"Setting the circulation pump clock program P1"; page 29
-
-