Страница 1: ...Room controller Como Operating and Installation Instructions Please follow the safety information and read through these Instructions carefully before placing the system into operation...

Страница 2: ...mmis sioned serviced and repaired profes sionally this will render the manufac turer s warranty null and void Declaration of conformity Como corresponds to the requirements of the relevant guidelines...

Страница 3: ...e the time and the day of the week in order to op erate the controller 1 Open the hinged front panel b 2 Press key 3 Select the language with keys 4 Press key twice 5 Set the time with keys 6 Press ke...

Страница 4: ...is pressed the heating circuit switches to Reduced mode for 1 further hour In Reduced mode ECO Each time key is pressed Re duced mode is prolonged by one hour Pressing the Party key shortens the set...

Страница 5: ...st protection Automatic 1 Auto matic 2 Heating mode Reduced night mode A C D E F H I J K M L B The standard display shows the following information A It is Saturday B The time is 12 47 C The current r...

Страница 6: ...he Programming key 4 If you press key and have se lected a lower operating level continue at Point 2 5 If you press key and have se lected a setting the controller changes to Programming mode Programm...

Страница 7: ...acti vate a switching time with the Pro gramming key Warning triangle and then save the value by pressing the Programming key again All switching values in the block are overwritten by the switch ing...

Страница 8: ...ith the delay setting PROPORTIONAL control Heating mode is switched on for a per centage 50 of the adjustable cycle time as a function of the deviation be tween the measured and desired tem perature o...

Страница 9: ...time advance required Setting of maximum time advance 0 Off 3 hours 2 hours RQWURO Control I 0 or Proportional mode Control I 0 RQWURO VWHUHVLV Hysteresis for ON OFF control HOD Delay for relay state...

Страница 10: ...he Holiday pro gram starts on the day of entry S HOLIDAY 00 with S HOLIDAY 05 in 5 days If the holiday period is entered after 12 00 hours the pro gram starts on the next day at 12 00 hours It thus al...

Страница 11: ...re engage the top section at the upper edge of the socket and swivel it back onto the base d Press on until the top section en gages in position For the fitter Installation A Hole for fastenings scre...

Страница 12: ...closure to EN 60529 IP 40 Safety class to EN 60730 II totally insulated Power reserve of the timer battery change 2 min Permitted ambient temperature during operation 0 to 50 C Permitted ambient tempe...