Odyssey OBC-6A Скачать руководство пользователя страница 10

General Operation

15

Charging a 12V Flooded or AGM (Absorbed Glass Mat) Lead Acid Battery.

Observe the instructions and safety information of the vehicle to find out how the vehicle

battery should be charged. Modern vehicles are equipped with sensitive electronic parts

and controls that can be damaged if you do not proceed properly.
a) First make sure your battery is a 12 volt flooded or AGM (Absorbed Glass Mat) lead acid

battery. Do not charge batteries with different operating voltages or chemistries.

b) Determine the chemistry of your battery. This should be on the battery or contact the 

battery manufacturer. This charger is for flooded and AGM lead acid batteries.

c) If the battery is installed in a vehicle, turn off the ignition and any other loads.
d) When the battery cables are connected per the instructions in this manual, and the 

charger is plugged in to AC power (115 V 60 Hz AC), the battery monitor and the 

AC power LEDs will illuminate.

e) If the Battery Trouble Status LED is illuminated, unplug AC connection of the charger 

from the electric outlet, check to make sure the connections are secure and the polarity

of the cables to the battery is correct. Plug the charger back into the electric outlet. If 

the Battery Trouble Status LED continues to illuminate there is a problem with the battery.

f)  There will be up to a two minute check process to make sure connections and the battery

are correct, then the charger will start the charge. When the charge cycle starts, the 

Charge Monitor LEDs will illuminate letting you know the battery charge level.

g) When all five charge monitor LEDs are illuminated the charge is complete and the charger

can be disconnected first from the AC power then the DC connection removed by first 

removing the negative clamp or connection followed by the positive clamp or connection.

h) See typical set up illustrations for in-vehicle and out-of-vehicle set up and use.

General Operation

16

Typical Setup - Charging In-Vehicle - Negative Chassis Ground
WARNING - Read and Follow all INSTRUCTIONS. FAILURE TO FOLLOW INSTRUCTIONS

MAY CAUSE SERIOUS INJURY, DAMAGE OR EXPLOSION, ALWAYS WEAR SAFETY

GLASSES.
Read and follow all General and Personal Safety Precautions in this manual and those

by the battery manufacturer.
Read and follow all the preparing to charge steps for in a vehicle battery charging.

Below please find the typical  steps for in a vehicle charging NEGATIVE (NEG, N, – ) chassis

ground vehicles.

a. Connect the red POSITIVE (POS, P, +) cable clamp to the POSITIVE (POS, P, +) post.
b. Connect the BLACK NEGATIVE (NEG, N, –) cable clamp to the vehicle’s chassis. 

Do not connect the black negative (NEG, N, –) cable clamp to metal fuel lines or 

anywhere in proximity of the carburetor or the battery itself.

c. Plug the charger into a properly grounded fault protected outlet.

Содержание OBC-6A

Страница 1: ...FCC Class A Part 15 CEC Listed ODYSSEY Battery12AmpPortableCharger OBC 12A 12 12 120VAC 10 6 9 25 x 11 25 x 3 88 ODYSSEY Battery20AmpPortableCharger OBC 20A 12 20 120VAC 10 6 9 25 x 13 75 x 3 88 Model...

Страница 2: ...being charged correctly The Self Test is automatic and will take place every time the unit is plugged into a 110VAC outlet The Self Test may take up to two minutes to complete During the Self Test th...

Страница 3: ...tains important safety and operating instructions for the ODYSSEY Battery Portable Charger WARNING To reduce the risk of injury to user or property the user must read and understand the instruction ma...

Страница 4: ...all EnerSys Energy Products Inc at 1 660 429 2165 between 8 30 am 5 00 pm Central Standard Time Unauthorized attempts to service repair or modify may result in a risk of electrical shock fire or explo...

Страница 5: ...parts Place away from the battery using the length of the DC cables l Consult vehicle owner s manual Personal Precautions 5 18 PREPARINGTOCHARGEA BATTERY CAUTION a When it is necessary to remove a bat...

Страница 6: ...njury to persons c Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post d Identify if you have a negative or positive grounded vehicle...

Страница 7: ...may be under 2 5 volts a red LED fault indicator will turn on and the System Check OK will not illuminate Equally a successful self test will result in a positive System Check OK LED illuminating foll...

Страница 8: ...e Batteries AGM Type Batteries Flooded AGM AGM Type Batteries AGM Type Batteries Flooded AGM Flooded Type Batteries Flooded Type Batteries 220 CCA through 330 CCA Flooded AGM For non cycling applicati...

Страница 9: ...alyzing Unit Self Test General Operation 13 ODYSSEY Battery Portable Charger LED Status Center Operation and Display The ODYSSEY Portable Charger includes seven LEDs for operation status and one batte...

Страница 10: ...h the battery f There will be up to a two minute check process to make sure connections and the battery are correct then the charger will start the charge When the charge cycle starts the Charge Monit...

Страница 11: ...Cable WARNING Read and Follow all INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE SERIOUS INJURY DAMAGE OR EXPLOSION ALWAYS WEAR SAFETY GLASSES Read and follow all General and Personal Safety P...

Страница 12: ...elf test This feature is to provide a rough indication of the charging process so at a glance you can see what charge level the battery is at and what remains to complete the charge process 100 First...

Страница 13: ...hechargerisnotundersizedforthebattery you are charging With the charger on using a digital volt meter read DC voltage across the battery If the DC voltage reading increases over time this will serve a...

Страница 14: ...chases contact Manufacturer at 800 964 2837 You will need to provide the order number original date of purchase serial number and date stamp from top of the charger At the sole discretion of Manufactu...