7. Do not use the battery charger unless the battery recommended charge voltage matches the

output voltage rating of the charger.

8. Use of an attachment not recommended or sold by EnerSys

®

 Energy Products Inc may 

result in a risk of fire, electric shock or injury to persons.

9. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when

disconnecting charger.

10.Extension cords should not be used unless absolutely necessary. Use of an improper 

extension cord could result in a risk of fire and electric shock. If an extension cord must be 

used make sure:
a. Use only a properly wired extension cord in good electrical condition.
b. Use an industrial grade / heavy duty UL or CSA approved extension cord. Check 

extension cord before use for damage, bent prongs, and cuts. Replace if damaged. 

Always make your extension cord connection on the charger side first. After connecting

the extension cord to the charger proceed to plug the extension cord into a nearby 120

VAC GFCI protected (Ground Fault Circuit Interrupt) outlet. Below are manufacturer 

recommendations for the right size UL or CSA Approved grounded extension cord.
i. Up to 50 feet in length use a 18 AWG extension cord.
ii. 50 to 100 feet in length use a 16 AWG extension cord.
iii. 100 to 150 feet in length use a 14 AWG extension cord.

11. Do not operate charger if any protective AC and DC cable insulation, charging clamps, DC fuse

holders and/or maintainer ring terminals have been damaged or compromised. Return the 

charger for service and repair to EnerSys

®

 Energy Products Inc immediately.

12. Do not operate the charger if it has received a sharp blow, direct hit of force, been dropped or 

otherwise damaged in any way. Return the charger for service and repair to EnerSys

®

 Energy

Products Inc immediately.

13. Do not disassemble charger.  Incorrect reassembly may result in a risk of electric shock or 

fire. If service or repair is required please call EnerSys

®

 Energy Products Inc at

1-660-429-2165 between 8:30 am - 5:00 pm Central Standard Time. Unauthorized attempts

to service, repair or modify may result in a risk of electrical shock, fire or explosion and 

will void warranty.

14. To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance

or cleaning. Turning off controls will not reduce risk.

15. Do not expose charger to rain or snow.

Important Safety Instructions

3

16.

GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

a. Charger should be grounded to reduce risk of electric shock. Charger is equipped with 

an electric cord having in equipment-grounding conductor and a grounding plug. The 

plug must be plugged into an outlet that is properly installed and grounded in 

accordance with all local codes and ordinances.

   

DANGER

Never alter AC cord or plug provided - If it will not fit outlet, have proper outlet installed by a 

qualified electrician. Improper connection can result in a risk of an electric shock.
b. This battery charger is for use on a nominal 120-volt circuit, and has a grounding 

plug that looks like the plug illustrated in Figure A. A temporary adapter, which looks

like the adapter illustrated in Figure B may be used to connect this plug to a two-

pole receptacle as shown in Figure B if a properly grounded outlet is not available. 

The temporary adapter should be used only until a properly grounded outlet can be 

installed by a qualified electrician.

 

DANGER

Before using adapter as illustrated, be certain that center screw of outlet plate is grounded. 

The green-colored rigid ear or leg extending from adapter must be connected to a properly 

grounded outlet - make certain it is grounded. If necessary, replace original outlet cover 

plate screw with a longer screw that will secure adapter ear or lug to outlet cover plate and 

make ground connection to grounded outlet.

Use of an adapter is not allowed in Canada. If a grounding type receptacle is not available,

do not use this appliance until the proper outlet is installed by a qualified electrician.

AC Cord Connections

4

Figure A

Grounding pin

Grounding means

Metal screw

Adapter

Figure B

Содержание OBC-12A

Страница 1: ...FCC Class A Part 15 CEC Listed ODYSSEY Battery12AmpPortableCharger OBC 12A 12 12 120VAC 10 6 9 25 x 11 25 x 3 88 ODYSSEY Battery20AmpPortableCharger OBC 20A 12 20 120VAC 10 6 9 25 x 13 75 x 3 88 Model...

Страница 2: ...being charged correctly The Self Test is automatic and will take place every time the unit is plugged into a 110VAC outlet The Self Test may take up to two minutes to complete During the Self Test th...

Страница 3: ...tains important safety and operating instructions for the ODYSSEY Battery Portable Charger WARNING To reduce the risk of injury to user or property the user must read and understand the instruction ma...

Страница 4: ...all EnerSys Energy Products Inc at 1 660 429 2165 between 8 30 am 5 00 pm Central Standard Time Unauthorized attempts to service repair or modify may result in a risk of electrical shock fire or explo...

Страница 5: ...parts Place away from the battery using the length of the DC cables l Consult vehicle owner s manual Personal Precautions 5 18 PREPARINGTOCHARGEA BATTERY CAUTION a When it is necessary to remove a bat...

Страница 6: ...njury to persons c Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post d Identify if you have a negative or positive grounded vehicle...

Страница 7: ...may be under 2 5 volts a red LED fault indicator will turn on and the System Check OK will not illuminate Equally a successful self test will result in a positive System Check OK LED illuminating foll...

Страница 8: ...e Batteries AGM Type Batteries Flooded AGM AGM Type Batteries AGM Type Batteries Flooded AGM Flooded Type Batteries Flooded Type Batteries 220 CCA through 330 CCA Flooded AGM For non cycling applicati...

Страница 9: ...alyzing Unit Self Test General Operation 13 ODYSSEY Battery Portable Charger LED Status Center Operation and Display The ODYSSEY Portable Charger includes seven LEDs for operation status and one batte...

Страница 10: ...h the battery f There will be up to a two minute check process to make sure connections and the battery are correct then the charger will start the charge When the charge cycle starts the Charge Monit...

Страница 11: ...Cable WARNING Read and Follow all INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE SERIOUS INJURY DAMAGE OR EXPLOSION ALWAYS WEAR SAFETY GLASSES Read and follow all General and Personal Safety P...

Страница 12: ...elf test This feature is to provide a rough indication of the charging process so at a glance you can see what charge level the battery is at and what remains to complete the charge process 100 First...

Страница 13: ...hechargerisnotundersizedforthebattery you are charging With the charger on using a digital volt meter read DC voltage across the battery If the DC voltage reading increases over time this will serve a...

Страница 14: ...chases contact Manufacturer at 800 964 2837 You will need to provide the order number original date of purchase serial number and date stamp from top of the charger At the sole discretion of Manufactu...

Отзывы: