1. Slide cable bend relief, back nut, cable collet, washer, sealing and EMI ring over the cable.
2. Strip cable and wire
corresponding the table
(see page 18).
3. Fit wire into the contact barrel
and crimp.
Assembly Straight Plug and In-line Receptacle IP 68
Crimp Version
010.055.000.000.000
Assembly Instructions
In-line receptacle
Plug
EMI ring
Half-shells
Crimp insert
Cable collet
Sealing
Back nut
(style 1)
Washer
(optional)
Back nut for
cable bend relief
(style 2)
cable bend
relief
Insert with
solder capacity