Echotrac CV100
User Manual
Page 30 of 30
Odom Hydrographic Systems, Inc.
May 28, 2008
6.3.4 DESO25
The following description applies to the selection of
DESO25
while only one frequency (either high or low) is
active.
DESO25 One Frequency Active
Character #
Character
Description
1
D
Always D
2
A,B
“A” for High Frequency, “B” For Low Frequency
3-10 DDDDDDDD
Depth
Data
11
<sp>, f
Space or “f” indicating feet units
12
m, t
“m” indicates meters, “t” indicates feet
13 CR
Carriage
Return
14 LF
Line
Feed
Example:
DB12345.69<SP>m<CR><LF>
; Lo, 12345.69 meters
*<CR><LF>
;
Terminator
symbol
6.3.5 DESO
DDV
The following description applies to the selection of
DESO DDV
while only one frequency (either high or low) is
active. Once every 2 seconds, the following two strings will also be output immediately after the DESO 25
outputstring has been output. There are two options: DESO_DDV_C and DESO_DDV_NOC. The former enables
chart control through Deso commands. The latter does not allow chart control through Deso commands.
DESO DDV Heave
Character #
Character
Description
1 D
Always
D
2 G
Always
H
3-5 DD
Heave
Data
6 .
Period
7-8
DD
Heave Data decimal
9 <sp>
Space
10
m
“m” indicates meters
11 CR
Carriage
Return
12 LF
Line
Feed
DESO DDV Draft
Character #
Character
Description
1 D
Always
D
2 G
Always
G
3-5 DD
Draft
Data
6 .
Period
7-8
DD
Draft Data decimal
9 <sp>
Space
10
m
“m” indicates meters
11 <sp>
Space
12 CR
Carriage
Return
13 LF
Line
Feed