2.8 – Numeric code setting 

The operator has two 6-digit numeric codes to associate with each weigh as an identifier 
merchandise or client.  

Set the desired value and confirm with COD.  
A short press will confirm the COD value entered as number 1 while a long press (3 sec.) 

Button COD will confirm the entered value as Code 2  
The two codes that you set are printed on the receipt and also on the COD code 1 will be 

carried out for aggregation operations per article, while the COD code 2 will be only printed 
without any operation of aggregation.  
The entered code is reset each aggregation, you can lock it so that it remains in memory until 

you change it by the operator;  
to do this enable the user to the menu item BL Cod 

 

2.9 - Total active code print  

It is possible to view and print the total number on the active product; To do this press keys in 
sequence 

 and COD.  

The total weight on Article active in memory at that time is displayed for 3 seconds. ; if there 
is a printer is issued a receipt which contains data related to that article ; The operator then 

has the option to cancel the value (ENTER = YES; ESC = NO) 
 

2.10 - View High Res Mode 

This function displays the current weight with a resolution 10 times higher.  
This display mode is activated by pressing keys in sequence 

 

and F3; to highlight the fact 

that the display is located in High Res, the last digit flashes.  
Press the button 

 to return to the standard display mode. 

 

2.11 - Display the battery charge level  

The level of charge of the internal battery of the instrument is divided on a scale from 1 to 10.  
Press the button 

 for 3 sec. ; the display will show the current charge level.  

Press the button  

 

to return to the standard display mode 

 

2.12 - Setting the set-point values (with I / O card)  

If the optional I / O is installed , the terminal SW22 lets you manage four values of 
interruption associated with four programmable relays which can be connected motors or 

valves loaded to handle then a batch formula.  
Press keys 

  and         

in sequence and enters the programming phase of the values of 

interruption described above.  

The display shows relay 1; to move to the next relay, use the 

 button.  

Press the button 

 to change the value of the relay desired; Enter the desired value and 

confirm with 

 

To exit the setup phase relays, press the key 

 

2.13 - Set Date and Time  

The terminal SW-22 has an internal clock that automatically increased.  
It is possible to change the current setting by pressing keys 

 and     

 in sequence, and the 

system is ready for you to enter the current date and time, press 

 

DAY to change the date 

or move to TIME to change the time.  

The instrument displays the values currently stored in the form ddmmyy and hh: mm, press  

 

to confirm the data displayed or press the key          and enter the new value and confirm 

with 

 . 

 

2.14 - Viewing Gross Weight / Net Weight  

The standard mode display provides the weight normally shown on the display is the Net 
Weight. By pressing the buttons 

and F1 will display the gross weight for 3 sec. turning off 

Содержание SW22

Страница 1: ...USER MANUAL WEIGHT INDICATOR MOD SW22 www odecasrl com...

Страница 2: ...40 C READABILITY Max 60000 divisions LEGAL DIVISIONS Max 10000 or 2x6000 or 3x3000 DISPLAY Red LED 6 digit display h 20 mm LED 8 status LED KEYBOARD waterproof LOAD CELL POWER SUPPLY 5Vdc 5 120mA max...

Страница 3: ...If led is off the weight is steady If led is on the SW21 is working with internal battery if led is blinking the battery is low and need to be recharged through the charger If led is on the weight on...

Страница 4: ...ape Programming Menu Decimal Point Enter Tare 0 9 Numeric Tare Value Lock Unlock Tare n Tare n recall Multiple Tare 3 sec Clear Tare Sampling Tare Archive Creation PMU Setting Date Time setting Set po...

Страница 5: ...SW22 4 User manual P1630830G Print total active code 3 Sec Print copy 3 sec Battery charge level Lock unlock keyboard Weighing delete Total by code Clear PMU...

Страница 6: ...tares press keys in sequence and The display is ready for entering the identification code of the tare you want to enter or change 1 to 9 displaying T 1 the selection is made with the and and confirm...

Страница 7: ...e button to return to the standard display mode 2 11 Display the battery charge level The level of charge of the internal battery of the instrument is divided on a scale from 1 to 10 Press the button...

Страница 8: ...buzzer to sound a single beep 2 16 Keyboard Lock It is possible for security reasons to disable the operation of the keyboard Press and keys in sequence the display will show for 3 seconds the message...

Страница 9: ...rom the keyboard and confirmed with If there is a printer a receipt is issued in accordance with the active mode with the given weight and number of pieces preceded by the sign 3 1 2 Reprint receipt I...

Страница 10: ...f pieces weight average piece weight and net weight 3 4 1 Sampling The first step to be carried out in an operation of counting is sampling This can be done in two modes Sampling charge on the weighin...

Страница 11: ...ight and number of pieces preceded by the sign 3 4 5 Display items PMU Net Weight Press keys and F2 in sequence switches the display mode of the number of pieces to that of the Average Piece Weight an...

Страница 12: ...1 First weighing By pressing the weight on the scale is considered first weighing value associated with an identification number of memory which will allow the call at second weighing The maximum allo...

Страница 13: ...W 22 provides the operator is that of Total for Item ie the sum of all items divided by code Press keys and in sequence and prints the total weight of all items with a value other than 0 in this case...

Страница 14: ...o indicate the status of ongoing dosing and close the exits n 1 2 and 4 card optional I O When the net weight reaches the set threshold value the display shows u xx x indicating the end of the assay w...

Страница 15: ...inal SW21 SW22 can be equipped optionally with an internal rechargeable battery at this stage it is possible to program the better off mode stand by in order to ensure the greatest possible independen...

Страница 16: ...rd and then the new password The supervisor password 14556 allows the access in every condition 4 8 ST BAR Bar code printing It is possible to print an EAN 13 bar code on a single ticket ON Barcode pr...

Страница 17: ...e used by SW22 to verify the correct reception this value is the operation XOR between characters ADDR and ETX EOT end transmission character EOT 04 Hex Weight request command Request ADDR CMD EOT 02...

Страница 18: ...eration 7 chr TARE tare 7 chr AWS Single average weight unit g 7 chr PCS number of pieces 6 chr COD 1 numeric code n 1 6 chr COD 2 numeric code n 2 6 chr PROGR serial weight number preceded by P or F...

Страница 19: ...ransmission character EOT 04 Hex 1 chr The fields MODE and ID are always in the form X IDYY where X represents the weight mode S I and U while YY represents the ID Code Single weight example STX M 1 1...

Страница 20: ...rmed Storage weighing not performed ACK is chr 06 Hex NACK is chr 15 Hex Scale selection command Request ADDR CMD SCALE EOT 02 Hex or 80 Hex address SW BIL 1 o 2 04 Hex Positive answer from SW22 negat...

Страница 21: ...Zero not performed ACK is chr 06 Hex NACK is chr 15 Hex Tare Command Request ADDR CMD PARAM ETX CHK EOT 02 Hex or 80 Hex address SW T Tare value 03 Hex checksum 04 Hex Where ADDR start transmission c...

Страница 22: ...smission character EOT 04 Hex 1 chr The batch value or the formula number must be right justified and filled with space 20 HEX Positive answer from SW22 Negative answer from SW22 batch started batch n...

Страница 23: ...CALW1 or CALW2 weight 03 Hex checksum 04 Hex Where ADDR start transmission character 1 chr CMD Command Code CALW scale number 1 or 2 5 chr PARAM calibration weight value 7 chr ETX end character ETX 03...

Страница 24: ...he decimal separator is 2C Hex Transmission example STX N S 2 450 0 000 0 000 0 000001 000000 F000131 ETX 66 EOT The frequency of the transmission is depending from the Refresh weight Frequency throug...

Страница 25: ...here ADDR start transmission character 1 chr CMD command code character M 1 chr SCALE scale number 1 or 2 1 chr NET net weight 7 chr TARE tare 7 chr GROSS gross weight or last weight 7 chr MODE weight...

Страница 26: ...SW22 25 User manual P1630830G 6 CONNECTIONS...

Страница 27: ...REFERENCE 13 REF REFERENCE 14 SIG SEGNALE ptf N 1 15 SIG SEGNALE ptf N 1 16 SIG SEGNALE ptf N 2 17 SIG SEGNALE PTF N 2 ALIMENTAZIONE ALIMENTAZIONE SEGNALE SEGNALE RIFERIMENTO RIFERIMENTO 6 2 Serial RS...

Страница 28: ...al RS232 Connection for printer EPSON TMU295 and LX300 GND 7 3 TX Connettore COM 1 Connettore 25 Pin Maschio Strumento 7 9 STAMPANTE RX 6 5 Serial RS232 Connection for label printer Zebra GK420 and pr...

Страница 29: ...8 57 9 58 59 60 61 62 63 64 65 A 66 B 67 C 68 D 69 E 70 F 71 G 72 H 73 I 74 J 75 K 76 L 77 M 78 N 79 O 80 P 81 Q 82 R 83 S 84 T 85 U 86 V 87 W 88 X 89 Y 90 Z 91 92 93 94 95 _ 96 97 a 98 b 99 c 100 d 1...

Страница 30: ...me Europee EN 55011 EN 50082 1 89 336 EU EMC Directive adopted European Standard EN 55011 EN50082 1 Direttive CEE 73 23 e 93 68 sulla sicurezza elettrica in bassa tensione Norma Europea EN 61010 1 73...