![Odeca SW22 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/odeca/sw22/sw22_user-manual_3338129007.webp)
SW22
6
User
manual
P1630830G
2.8 – Numeric code setting
The operator has two 6-digit numeric codes to associate with each weigh as an identifier
merchandise or client.
Set the desired value and confirm with COD.
A short press will confirm the COD value entered as number 1 while a long press (3 sec.)
Button COD will confirm the entered value as Code 2
The two codes that you set are printed on the receipt and also on the COD code 1 will be
carried out for aggregation operations per article, while the COD code 2 will be only printed
without any operation of aggregation.
The entered code is reset each aggregation, you can lock it so that it remains in memory until
you change it by the operator;
to do this enable the user to the menu item BL Cod
2.9 - Total active code print
It is possible to view and print the total number on the active product; To do this press keys in
sequence
and COD.
The total weight on Article active in memory at that time is displayed for 3 seconds. ; if there
is a printer is issued a receipt which contains data related to that article ; The operator then
has the option to cancel the value (ENTER = YES; ESC = NO)
2.10 - View High Res Mode
This function displays the current weight with a resolution 10 times higher.
This display mode is activated by pressing keys in sequence
and F3; to highlight the fact
that the display is located in High Res, the last digit flashes.
Press the button
to return to the standard display mode.
2.11 - Display the battery charge level
The level of charge of the internal battery of the instrument is divided on a scale from 1 to 10.
Press the button
for 3 sec. ; the display will show the current charge level.
Press the button
to return to the standard display mode
2.12 - Setting the set-point values (with I / O card)
If the optional I / O is installed , the terminal SW22 lets you manage four values of
interruption associated with four programmable relays which can be connected motors or
valves loaded to handle then a batch formula.
Press keys
and
in sequence and enters the programming phase of the values of
interruption described above.
The display shows relay 1; to move to the next relay, use the
▲
button.
Press the button
to change the value of the relay desired; Enter the desired value and
confirm with
To exit the setup phase relays, press the key
.
2.13 - Set Date and Time
The terminal SW-22 has an internal clock that automatically increased.
It is possible to change the current setting by pressing keys
and
in sequence, and the
system is ready for you to enter the current date and time, press
DAY to change the date
or move to TIME to change the time.
The instrument displays the values currently stored in the form ddmmyy and hh: mm, press
to confirm the data displayed or press the key and enter the new value and confirm
with
.
2.14 - Viewing Gross Weight / Net Weight
The standard mode display provides the weight normally shown on the display is the Net
Weight. By pressing the buttons
and F1 will display the gross weight for 3 sec. turning off