4.3  INTEST:  Receipt Header setting 

It is possible to memorize three header lines that can be used while printing. 
It is possible to choose the font; le possible choices are: normal, double height, expanded, 
bold. 

   

According to the choice made, the number of available alphanumeric symbols changes: if you 
choose the normal font, you have 24 alphanumeric symbols, whereas in the other three cases, 
the alphanumeric symbols are just 12.  

<SCRIVI>  

insertion mode for three heading lines. (LINE 1 - LINE 2 – LINE 3) 

 

Settings available for each line: 

NONE    

(if  you  don’t  want  to  send  the  variable  to  the  labelling  machine)  see 

parag. 8.7/8.8 

 

NORMAL 

24 alphanumeric symbols maximum 

 

GRASS   

12 alphanumeric symbols maximum 

 

2 ALT   

24 alphanumeric symbols maximum 

 

2 LARG  

12 alphanumeric symbols maximum 

Each  alphanumeric  symbol  is  inserted  through  the  decimal  ASCII  codification  (a 

summarizing chart is attached). In order to conclude, confirm the immission of “000”. 

Ex. ODECA s.r.l. (079 – enter – 068 – enter - 069 – enter - 067 – enter - 065 – enter - 

032 – enter - 115 – enter - 046 – enter - 114 – enter - 046 – enter - 108 – enter - 046 – 
enter - 000 - enter 

 
 

If the  chosen  printer  is different  from the  labelling  machine,  the  line  added  as 
verify is printed.   

<CANCEL>   Cancellation of what has been added. 
 

4.4 B-TARA:  Tare Block  

It is possible to block the tare leeping it active after each operation. 
 

4.5  STP-1  : Serial printing 1 setting  

it is possible to set some parameters referred to the printer connected with the serial 1  
<MULTIP> : it enables the multiple printing  
<ST-BAR> : it enables the printing of the EAN8 barcode on the receipt  
<LF-INI>: it sets the empty lines for the beginning of the printing  
 

4.6  STP-2  : Serial printing 2 setting   

It is possible to set some parameters referred to the printer connected with the serial 2   
<MULTIP> : it enables the multiple printing   
<ST-BAR> : it enables the printing of the EAN8 barcode on the receipt EAN8  
<LF-INI>: It sets the empty lines for the beginning of the printing  
 

4.7  FISCAL  : Fiscal Memory reading   

it is possible to find this option only if it has been enabled an optional memory thanks to which 
each weight is memorized in a hard memory accessible only on explicit demand. 
The capacity of this memory allows to memorize 170000 weights maximum.  

Setting  the  address  of  the  desired  location  (from  1  to  170000)  the  data  of  the  weight 
contained and the date are shown. 
If the location is still empty, the message “No-FIS” is shown, whereas, if there is a weight, first 
the date is shown and then saved weight value.  
 
 
 
 
 
 
 
 
 

 
 
 

Содержание LA715

Страница 1: ...USER MANUAL WEIGHT INDICATOR MOD LA715 www odeca it...

Страница 2: ...LED 6 digit display h 20 mm LED 4 Status LED KEYBOARD Touch keyboard with 12 keys LOAD CELL POWER SUPPLY 5Vdc 5 120mA max 8 load cell 350 Ohm LOAD CELL CONNECTION 6 wires with Remote Sense CASE Stainl...

Страница 3: ...is on the weight is between 1 4 1 4 of zero If led is off the weight is steady If led is on the SW21 is working with internal battery if led is blinking the battery is low and need to be recharged thr...

Страница 4: ...ion clear Tare PRINT 4 Print 3 sec pression Print total TOT 5 Display Total EXIT Esc ON OFF 6 On OFF 7 High resolution display 10 TARGET 8 Set target n 1 and n 2 9 Display Gross weight MENU 0 3 sec pr...

Страница 5: ...s the key SET TARE 3 for 3 sec The Gross is shown once again and the signal led of the net weight turns off in order to confirm that the memorized tare has actually been cancelled 2 4 Visualization in...

Страница 6: ...U 4 1 CLOCK Date and Time Setting The device LA715 has a calendar clock that automatically increases even without external power source In this phase it is possible to modify the current date and time...

Страница 7: ...m the labelling machine the line added as verify is printed CANCEL Cancellation of what has been added 4 4 B TARA Tare Block It is possible to block the tare leeping it active after each operation 4 5...

Страница 8: ...tifield enabling The Multifield operation allows to divide the weighing range of the scale into two or three 3000 div Each weighing subsets or into two 6000 div Each subsets It allows if the loading c...

Страница 9: ...dmitted by the system in order to consider the weight stable The higher the number of divisions the lower the sensitivity Then the stability is more easily signalled Admitted values from 0 to 4 5 5 0...

Страница 10: ...2 PERIF BAUD FRAME NOCOM ADDRES 6 2 USCITE USC 1 STATO PESO STABLE USC 2 STATO PESO STABLE 6 3 TOTAL AB TOT M TOT P MIN ABIL P 6 4 LINGUA 6 5 M FISC 6 6 NPROG 6 7 NO OFF 6 8 CALTAS 6 1 DEVICE Serial c...

Страница 11: ...protocols on demand Setting Yes No if Yes is set it is possible to decide whether to visualize it fixed or flashing 6 2 3 ADRESS Programming address of the device from 0 to 99 If the address is 0 it i...

Страница 12: ...n order to be able to print again The second one is a variation of weight a simple variation of weight allows to print again In the end no condition is necessary in order to print twice consequently T...

Страница 13: ...LA715 12 User ManualP2640300...

Страница 14: ...ells CONNESSIONE A 4 FILI 1 EXC ALIMENTAZIONE 2 EXC ALIMENTAZIONE 3 REF Cortocircuitare con morsetto 11 4 REF Cortocircuitare con morsetto 10 5 SIG SEGNALE 6 SIG SEGNALE ALIMENTAZIONE ALIMENTAZIONE SE...

Страница 15: ...s C ZONA C 9 80129 m s SICILIA 2 SICILIA 2 9 79819 m s G NUM It can be manually added TABLE 2 Territorial Correspondence of the zones A B C SICILIA2 ZONA A ZONA B ZONA C ZONA SICILIA 2 EMILIA ROMAGNA...

Страница 16: ...3 52 4 53 5 54 6 55 7 56 8 57 9 58 59 60 61 62 63 64 65 A 66 B 67 C 68 D 69 E 70 F 71 G 72 H 73 I 74 J 75 K 76 L 77 M 78 N 79 O 80 P 81 Q 82 R 83 S 84 T 85 U 86 V 87 W 88 X 89 Y 90 Z 91 92 93 94 95 _...

Страница 17: ...ity Direttiva CEE 89 336 sulla Compatibilit Elettromagnetica Norme Europee EN 55011 EN 50082 1 89 336 EU EMC Directive adopted European Standard EN 55011 EN50082 1 Direttive CEE 73 23 e 93 68 sulla si...

Страница 18: ...and board If the instrument is sent through courier the costs of transport a r are in charge of the Customer The WARRANTY DECADES in case of breakdowns caused by interventions of not authorized peopl...

Отзывы: