9
Chapter 1:
Overview
≡
Description
The 5624 Isolated Digital I/O Card accepts switch closures, PLC and
12V logic inputs and other voltages that can not be used with
standard TTL logic. The card supports 16 input channels and 8
output channels. The inputs have 500V of isolation to ground and
100V between channels. The eight output channels will drive relays,
lamps, small motors, and solenoids. Each channel can switch loads up
to 200 mA and 50V. Signals may be AC or DC. Each output is
isolated from each other and the system. As shipped, the 5624 will
accept signals from 9–58V DC. A plug–in resistor pack allows the
user to accommodate ranges from 3V to 84V.
The 5624 is protected from accidental reverse polarity. Noise filtering
is provided, and the system is not damaged by 200V noise pulses. All
inputs are isolated from each other and the system ground.
The card measures 4.5 x 4.9 inches and operates on +5V. It is
compatible with all Micro PC Control Cards and Microcontrollers and
can be installed in an ISA slot in a desktop PC.