ALLURE_NEWPORT_INTRIGUE-O1OA-LED-INSTALLATION_INSTRUCTIONS
OCL Architectural Lighting
Phone: 314.863.1895
Fax: 314.863.3278
Rev date: 14 APR 2021
Sensitivity: Internal & Restricted
5.
Mark ANCHOR HOLE locations on wall using BACKPLATE. Drill 3/16" dia. holes, and insert provided
ANCHORS as shown in FIG. 10.
NOTE:
Apply Thick Bead of Silicone around J-BOX.
Failure to do so will void all warranties. Make sure
that Bead is completely outside of fixture mounting hole location.
6.
Pull Black, White & Green supply wires through center hole of BACKPLATE as shown in FIG. 11. For
Vertical Mounted fixtures, make sure the GASKET SEAM is on the bottom. Mount BACKPLATE directly to J-
BOX and secure to wall using provided ANCHOR SCREWS and SEALING WASHERS.
7.
Attach the provided Black and White conductors to the Building Supply conductors. Make all wire
connections in accordance with NATIONAL ELECTRICAL LOCAL AND STATE CODES. Push the wire
connections back into the J-BOX. Make a THREE-WAY CONNECTION using the PIG TAILED GREEN
CONDUCTORS from the REFLECTOR to the Green conductor on the BACK PLATE, and the Building Supply
Ground. Push wire connections back into box SEE WIRE LABEL TABLE as shown in FIG. 12 for wire
connection.
WIRE DIAGRAM TABLE
SERIES
HANGING
SYSTEM
BODY
SIZE
BODYLIGHT
SOURCE
LED
OUTPUT
CONTROL
WIRE LABEL
TABLE
1. ALLURE
(AU1)
2. NEWPORT
(NP1)
3. INTRIGUE
(IN1 & IN2)
O1OA:
OUTDOOR
SCONCE
18”
24”
36”
48”
STATIC
WHITE
LED1
LED2
DM1: 0-10V DIM 1%
WIRE LABEL
TABLE ON
PAGE 5
GASKET SEAM
ANCHOR
SCREWS
SEALING
WASHER
WALL
SILICONE
BEAD
ANCHORS
FIG.10 – BACK PLATE ASSEMBLY TO J-BOX
FIG.11 – WIRE CONNECTION INFORMATION
3 WAY GROUND
CONNECTION
FIG. 12 – WIRE LABEL TABLE