5.

 

Mark ANCHOR HOLE locations on wall using BACKPLATE. Drill 3/16" dia. holes, and insert provided 
ANCHORS as shown in FIG. 10. 

 

NOTE:

 

Apply Thick Bead of Silicone around J-BOX.

 

Failure to do so will void all warranties. Make sure 

that Bead is completely outside of fixture mounting hole location.

 

 

 

6.

 

Pull Black, White & Green supply wires through center hole of BACKPLATE as shown in FIG. 11. For 
Vertical Mounted fixtures, make sure the GASKET SEAM is on the bottom. Mount BACKPLATE directly to J-
BOX and secure to wall using provided ANCHOR SCREWS and SEALING WASHERS. 

7.

 

Attach the provided Black and White conductors to the Building Supply conductors. Make all wire 
connections in accordance with NATIONAL ELECTRICAL LOCAL AND STATE CODES. Push the wire 
connections back into the J-BOX. Make a THREE-WAY CONNECTION using the PIG TAILED GREEN 
CONDUCTORS from the REFLECTOR to the Green conductor on the BACK PLATE, and the Building Supply 
Ground. Push wire connections back into box SEE WIRE LABEL TABLE as shown in FIG. 12 for wire 
connection. 

 
 
 
 
 
 
 
 
 

WIRE DIAGRAM TABLE 

SERIES 

HANGING 

SYSTEM 

BODY 

SIZE 

BODYLIGHT 

SOURCE 

LED 

OUTPUT 

CONTROL 

WIRE LABEL 

TABLE 

 1. ALLURE 

(AU1) 

2. NEWPORT 

(NP1)

 

3. INTRIGUE 

(IN1 & IN2) 

O1OA:

 

OUTDOOR 

SCONCE 

18” 

24” 

36” 

48” 

STATIC 
WHITE 

LED1 

 
 

LED2 

 

DM1: 0-10V DIM 1%  

WIRE LABEL 

TABLE ON 

PAGE 5 

GASKET SEAM 

ANCHOR 

SCREWS 

SEALING 

WASHER 

WALL 

SILICONE 

BEAD 

ANCHORS 

FIG.10 – BACK PLATE ASSEMBLY TO J-BOX 

FIG.11 – WIRE CONNECTION INFORMATION 

3 WAY GROUND 

CONNECTION 

FIG. 12 – WIRE LABEL TABLE 