Warranty  

LENGTH OF WARRANTY

One (1) Year Full parts and Labor residential warranty:

Covers the entire product from the original purchase

date indicated on the sales receipt.

Ninety (90) days commercial warranty:

Full parts and Labor Covers the entire product from the original pur-

chase date indicated on the sales receipt for units installed in commercial applications such as apartments,
restaurants, service garages, car dealerships and food service locations etc.

OCI WILL PAY FOR

All repair labor and parts found to be defective due to materials or workmanship for one full year “IN HOME” war-
ranty during the first year of ownership. This does not apply if the unit was subjected to other than normal house-
hold use or mis-installation. Service must be provided by Authorized Factory Agent during normal working hours.
No charges will be made for repair or replacement at the location of initial installation or factory for parts returned
pre-paid, through the dealer and claimed within the warranty period, and found by OCI to be defective.

Replacement will be F.O.B. OCI and OCI will not be liable for any transportation costs, labor costs, or export
duties. This warranty shall not apply, nor can we assume responsibility for damage that might result from failure
to follow manufacturers instructions or local codes,where the appliance has been tampered with or altered in any
way or which, in our judgement, has been subjected to misuse, negligence, misinstallation or accident. Implied
warranty shall not extend beyond the duration of this written warranty. This warranty is in lieu of all warranties
expressed or implied and all other obligations or liability in connection with the sale of this appliance.

OCI Will Not Pay For

l

Installation or start-up.

l

Shipping damage.

l

Service calls to diagnose a problem.

l

Service by an unauthorized agency.

l

Damage or repairs due to service by an unauthorized agency or the use of unauthorized

parts.

l

Service during other than normal working hours.

l

Any service if the included regulator is not used.

l

Costs to correct improper installation, such as improper hook-up,, mounting etc.

l

Service visits to teach you how to use the appliance; correct the installation; reset circuit

breakers or replace home fuses.

l

Cleaning of filters and outer panels.

l

Repairs due to other than normal household use.

l

Damage caused from accident, abuse, alteration, misuse, incorrect installation or installation

not in accordance with local codes.

l

Units installed in non-residential application such as day care centers, bed and 

breakfast centers, churches, nursing homes, restaurants, hotels, schools, Rental 

units etc. are covered for a period of 90 days from the original purchase date

l

Cosmetic damage past the first 90 days.

l

Normal surface corrosion, or corrosion as a result of geographical location.  (i.e. coastal locations)

This warranty applies to appliances used in residential applications; it does not cover their use in commercial sit-
uations past 90 days. This warranty is for products purchased and retained in the 50 states of the U.S.A., the
District of Columbia and Canada. This warranty applies even if you should move during the warranty period.
Should the appliance be sold by the original purchaser during the warranty period, the new owner continues to
be protected until the expiration date of the original purchaser’s warranty period. This warranty gives you specific
legal rights. You may also have other rights which vary from state to state.

*Because of continuing product

improvement these specifications are subject to change without notice.

23

Содержание OCIE48EH

Страница 1: ...Goldenwest Circle Westminster California 92683 714 903 1885 www ociproducts com P N 110254 rev 4 10 2011 Built to Perform Because of continuing product improve ment the specifications in this manual a...

Страница 2: ...Overhead Heater Installation Operation Guide Model OCIE48EH Living Elegant Built to Perform...

Страница 3: ...port Specialist by phone 1 714 903 1885 For product questions or concerns you may also contact us via email at support ociproducts com Additionally you may also write to us at OCI Products Attention C...

Страница 4: ...GAS SUPPLY 10 GAS CONNECTION DIAGRAMS 11 LEAK TESTING 12 TURN POWER ON LIGHTING OPERATION INSTRUCTIONS 13 TURN POWER OFF REMOTE SETUP 14 15 AC POWER HOOKUP 15 WIRING DIAGRAM SCHEMATIC 16 CONVERTING TO...

Страница 5: ...INSTRUCTIONS section of this manual l Do not use in an explosive atmosphere keep heater away from areas where gasoline or other flammable liquids or vapors are stored or used l Before each use check f...

Страница 6: ...th caution Avoid steam burns do not use a wet sponge or cloth to clean the heater while it is hot Some cleaners produce noxious fumes or can ignite if applied to a hot surface l Be sure all heater con...

Страница 7: ...ng facility Parts included 1 OCIE48EH HEATER UNIT 4 3 8 16 X 3 4 SS BUTTON HEAD BOLTS 4 3 8 16 SS NYLOCK NUTS 4 1 4 20 X 1 2 SS HEX BOLTS 2 SS HEATER ARM MOUNT BRACKETS 2 SS ARM BRACKETS 1 HEATER REMO...

Страница 8: ...o Z223 1 National Fuel Gas Code and any applicable local codes In Canada the installation must conform with local building codes or in the absence of local codes with National stan dards of Canada CAN...

Страница 9: ...erials are defined as wood paper foliage plastic plexiglass or other materials capable of being ignited and burned Such materials shall be considered combustible even though flame proofed fire retarda...

Страница 10: ...vided by the manufacturer heater must be leveled only on a Horizontal Axis but can be angled to a maximum of 30 degrees in reference to the floor DO NOT mount the heater on a vertical axis DO NOT modi...

Страница 11: ...nt the heater on the already mounted mount arm brackets using the 4 3 8 16 X 3 4 SS button head bolts 4 3 8 SS lock washers and 4 3 8 16 SS hex nuts provided as shown below Position the heater accordi...

Страница 12: ...nting brackets provided by the manufacturer Heater must be leveled only on a horizontal axis but can be angled to a maximum of 30 degrees in reference to the floor DO NOT mount the heater on a vertica...

Страница 13: ...s shown below Install the four 4 AA batteries as indicated on inside of box Reinstall box cover and reinstall heater access panel Connect Gas Supply Gas line requirements A minimum pipe size of 1 2 is...

Страница 14: ...Gas Connection Diagrams Recommended Gas hookup 11...

Страница 15: ...of the gas supply connection to the heater NOTE Gas connections on the heater are leak tested at the factory prior to shipment Precautions l Periodically check the whole gas system for leaks or immed...

Страница 16: ...e gas supply is turned on The heater will simply go through its cycle of turning the pilot burn er on and then automatically turn the heater main burner on Once lit the Heater defaults to the HI setti...

Страница 17: ...Heater defaults to the HI setting Programming the Remote Control The OCIE48EH must be programmed to the Remote control before it will operate It is possible to program up to three different remote co...

Страница 18: ...black wire to stepper motor making sure to attach Black to Black and Red to Red 4 Connect wire leads from power convertor supplied with your heater unit to the AF 4000 MOD control module located insi...

Страница 19: ...Wiring Diagram Schematics 16 Because of continuing product improvement these specifications are subject to change without notice...

Страница 20: ...you Step 1 Remove the control access panel located on the side of the heater using a phillips screwdriver Locate the Brass main orifice fitting at the root of the burner Using a 1 2 open end wrench r...

Страница 21: ...10 5 wc propane 5 Replace the aluminum cover cap Step 4 Locate on the control the screw that says pilot adj and adjust flame height using a small flathead screwdriver To lower the flame screw in clock...

Страница 22: ...rvice or maintenance can cause property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment Failure to mount ac...

Страница 23: ...This eventually will go away and it doesn t effect the performance of the heater Before Calling for Service Basic Troubleshooting Important An experienced qualified service technician should perform...

Страница 24: ...With the control panel open check if green wire is grounded Symptom Remote control communicates with heater but heater will beep and no sparks to pilot 1 Pilot sensor is dampened or wet Installation...

Страница 25: ...RACKET BACK PANEL HIGH OUTPUT IR BURNER RIGHT BURNER MOUNT HEAT SHIELD RIGHT PANEL BOTTOM PANEL CURVED FASCIA WELD ASSY GRILL ASSEMBLY ACCESS DOOR MOUNT ARM MOUNT BRACKET ACCESS PANEL PART 130053 1300...

Страница 26: ...his appliance OCI Will Not Pay For l Installation or start up l Shipping damage l Service calls to diagnose a problem l Service by an unauthorized agency l Damage or repairs due to service by an unaut...

Страница 27: ...am 4 00 pm PST Before you call please have the following information ready l Model Number l Serial Number l Date of installation l A brief description of the problem Your satisfaction is of the utmost...

Страница 28: ......

Отзывы: