982017-AIR-BASIC-Multitower-T201-EN01.docx
Page 16 of 60
The system is controlled via the integral OTE3 heat
pump manager. For adjustment options, see the
controller operating manual.
4.1.1.4 Multifunctional assembly (MFA)
The multifunctional assembly switches between
heating circuit and DHW heating. It also includes
the safety valve, an air vent valve the flow sensor
and the electric emergency heater.
4.1.1.5 Accessories pack
The following components are packed inside the
MULTI TOWER, next to the two pumps:
-
Outside temperature sensor
-
Adjustable feet
-
Drain hose
-
Operating manual
-
1 expansion vessel (incl. fastening
material)
-
1 installation kit (pressure reducing valve,
check valves, expansion, relief valve,
tundish)
Gaskets for the hydraulic connection (heating
circuit flow, heating circuit return, cold water,
DHW) are attached directly at the connections.
4.1.2 Main components
1
Magnesium anode
2
Air vent valve (MFA)
3
Electric booster heater 8.8 kW (MFA)
4
Safety valve (MFA)
5
3-way switching valve (MFA)
6
Electrical connection
7
Cable entries
8
Maintenance flange
9
Drain stopcock
10
Buffer tank (100 l)
11
Drain stopcock
12
Heating circuit pump
13
Buffer charging pump
14
DHW tank (168 l)
15
Condenser (plate heat exchanger)
16
High limit safety cut-out (MFA)
17
Air vent valve
Figure 14: Main components in T201 indoor unit
Содержание AIR BASIC 211 T201
Страница 50: ...982017 AIR BASIC Multitower T201 EN01 docx Page 50 of 60 11 8 Declaration of conformity...
Страница 51: ...982017 AIR BASIC Multitower T201 EN01 docx Page 51 of 60...
Страница 52: ...982017 AIR BASIC Multitower T201 EN01 docx Page 52 of 60...
Страница 53: ...982017 AIR BASIC Multitower T201 EN01 docx Page 53 of 60...
Страница 54: ...982017 AIR BASIC Multitower T201 EN01 docx Page 54 of 60 11 9 ERP Data...
Страница 55: ...982017 AIR BASIC Multitower T201 EN01 docx Page 55 of 60...
Страница 57: ...982017 AIR BASIC Multitower T201 EN01 docx Page 57 of 60...
Страница 58: ...982017 AIR BASIC Multitower T201 EN01 docx Page 58 of 60...
Страница 59: ...982017 AIR BASIC Multitower T201 EN01 docx Page 59 of 60...