OCEM Multi Electric LRTH04 Скачать руководство пользователя страница 3

Document UT-MT-0780_EN 

Page 3 of 39 

Edition 03/10/2015 

Supersedes edition 03/11/2014 

LED INSET THRESHOLD AND THRESHOLD WING BAR LIGHT 

LRTH04

INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE 

OPERATION ON THE EQUIPMENT - SKILLS 

Operation  on  the  equipment  and  access  to  its  internal  parts  shall  be  done  by  experienced  personnel, 
adequately trained and aware of the risks related to electricity and high voltages. 
Safety  rules  shall  be  adopted  when  operating  on  the  equipment,  or  on  cables  and  other  apparatus 
connected to the it 

DO NOT OPERATE ON ENERGIZED CIRCUITS 

Do  not  carry  out  any  operation on the  converter or on  apparatus  connected to  it  when the  circuits  are 
energized. 

WHEN HANDLING AND SERVICING THIS EQUIPMENT, OBSERVE PRECAUTIONS FOR HIGH VOLTAGE 

EQUIPMENT. 

Before  any  access,  inspection  or  intervention,  be  sure  to  have  switched-off  the  unit,  opened  the  main 
circuit  breaker  and  removed  the  supply  to  the  unit  (by  opening  the  circuit  breaker/switch  on  the 
distribution board at the beginning of the supply line) . 

Then  wait  discharge  time  (at  least  5  minutes) ,  ground  carefully  the  system,  and  check  for  voltage 
presence before accessing.. 

REANIMATION 

The  maintenance  staff  must  be  aware  of  the  risks  related  to  electricity,  criteria  to  prevent  the  risk  of 
electric shock and resuscitation techniques 

CE MARK 

This  equipment  complies with  the  requirements of European  regulations  for  the  CE mark.The 
user has to respect all prescriptions reported in this document. 
This  equipment  complies  with  the  requirements  of  the  EEC  directives  2004/108/EEC  and 
2006/95/EEC  with  regard  to  “Electromagnetic  Compatibility”  and  “Low  Voltage  Electrical 
Apparatus” respectively. 

OUT OF SERVICE 

In  case  of  dismantling,  decommissioning,  destruction,  disposal,  the  user  shall  follow  all  the  required 
precautions for component and material elimination, according to local rules and applicable law. 

Содержание Multi Electric LRTH04

Страница 1: ...IGNED ON REQUEST THIS DOCUMENT AND THE DATA CONTAINED HERE IN IS PROPRIETARY PROPERTY AND SHALL NOT BE DUPLICATED USED OR DISCLOSED IN WHOLE OR IN PART FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF OCEM...

Страница 2: ...nted within the applicable warranty period All costs of transportation of Products claimed not to be warranted and of those repaired or replaced to or from the facility of the Company shall be borne b...

Страница 3: ...itched off the unit opened the main circuit breaker and removed the supply to the unit by opening the circuit breaker switch on the distribution board at the beginning of the supply line Then wait dis...

Страница 4: ...N MANUAL FOR USE INSTALLATION AND MAINTENANCE EDITIONS Date 07 24 2013 First issue 02 03 2014 03 11 2014 03 10 2015 Deleted List of the recommended spare parts and added relevant attachment New addres...

Страница 5: ...C SECTION 15 2 3 1 Current current conversion circuit patented 15 2 3 2 LED command circuit 15 2 3 3 Control circuit 16 2 4 ARCTIC KIT 16 3 INSTALLATION 17 3 1 PAVEMENT BORING AND SAWCUTTING 17 3 1 1...

Страница 6: ...Figure 2 Lower Cover Outside View 10 Figure 3 Lower Cover Inside View 11 Figure 4 Wiring Diagram 11 Figure 5 Exploded View 12 Figure 6 Part List 13 Figure 7 Complete P N identification 13 Figure 8 Sta...

Страница 7: ...NG BAR LIGHT LRTH04 INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE Figure 24 Fixture Gaskets 35 Figure 25 Prism Gasket 35 Figure 26 Cable Lead With Plug 36 Figure 27 Lower Cover with Pressure...

Страница 8: ...xture is waterproof and designed to withstand aircraft impact and roll over loads without damage The beam toe in is obtained inside the light unit through different positioning of the light source In...

Страница 9: ...Figure 5 n 15 and two LED module Figure 5 n 7 with reflector threshold or lens array threshold wing bar Figure 5 n 6 Three optical assemblies with toe in are available for this fixture Straight S Lef...

Страница 10: ...etween fixture and shallow base is ensured by means of an O Ring separately supplied to be placed on the relevant shallow base groove The fixture is supplied with one cable lead with L 823 plug it con...

Страница 11: ...INSTALLATION AND MAINTENANCE The same colour painting is provided outside on the lower cover See Complete P N identification figure for P N information All hardware is made of stainless steel 1 Cable...

Страница 12: ...T MT 0780_EN Page 12 of 39 Edition 03 10 2015 Supersedes edition 03 11 2014 LED INSET THRESHOLD AND THRESHOLD WING BAR LIGHT LRTH04 INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE Figure 5 Exp...

Страница 13: ...module with accessories 2 8 Lower cover 1 9 Valve for watertightness test 1 10 FAA L 823 plug 1 11 Arctic kit thermostat 1 12 Prism gasket 2 13 Prism 2 14 Prism holder gasket 2 15 Mounting plate 2 Fig...

Страница 14: ...ed close to the cable entry The shallow base is designed for cementing in place by means of epoxy resin in a hole drilled in the pavement The fixture has to be fastened to the base by means of six hex...

Страница 15: ...eries circuit isolation transformers of smaller size can be used respect to those used with the equivalent fixtures equipped with halogen lamps To meet the previous features the conversion circuit is...

Страница 16: ...nic control circuit commands the intervention of the monitoring device so that the secondary side of the isolation transformer becomes open like in the case of an incandescent lamp failure This featur...

Страница 17: ...ecess size and depth are maintained within the specified limits All surfaces of the recess must be clean and dry If any of these surfaces is damp it is desirable that it be dried and blown clean with...

Страница 18: ...80_EN Page 18 of 39 Edition 03 10 2015 Supersedes edition 03 11 2014 LED INSET THRESHOLD AND THRESHOLD WING BAR LIGHT LRTH04 INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE 3 1 1 Scheme of Lig...

Страница 19: ...Page 19 of 39 Edition 03 10 2015 Supersedes edition 03 11 2014 LED INSET THRESHOLD AND THRESHOLD WING BAR LIGHT LRTH04 INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE Figure 10 Example of Lig...

Страница 20: ...eads to the power cables using solderless squeeze connectors as shown in the figure crimped with the proper tool Connect also the grounding wire to the main grounding network by using a suitable clamp...

Страница 21: ...een the sides of the shallow base and the drilled hole should be filled with sealer up to approx 25 mm from the pavement according to the local needs Fill the remaining 25 mm with a suitable joint sea...

Страница 22: ...the grounding wire of the fixture with the receptacle and the grounding wire of the base press the fixture by hand onto the base and secure it using the six locking screws complete with washer one dro...

Страница 23: ...D MAINTENANCE 320 320 100 150 150 Figure 12 12 shallow base for side or bottom ducts method B 1 Positioning jig 2 Align the jig notch with the mark on the pavement 3 Circular level 4 Screws and spacer...

Страница 24: ...ure it shall be complete of adaptor ring Be sure the flange on the transformer housing is clean and the O Ring Figure 15 n 2 if used is in place in the O Ring groove Connect the plug of the fixture to...

Страница 25: ...transformer provided with earthing connection the fixture secondary side is wired to the grounding network through the larger pin of fixture plug In case of an inset fixture installed in the taxiway r...

Страница 26: ...t fixture life the installed units should be subject to a maintenance program in accordance with the following instructions and taking as reference the Airport Service Manual ICAO Part 9 Airport Maint...

Страница 27: ...fixture by using the two lifting tools P N 332 4140 or 332 4230 inserted in the suitable slots provided on the dome As an alternative two screwdrivers can be used Disconnect the fixture plug s and gro...

Страница 28: ...ernal air pressure line to the valve Figure 17 n 2 provided on the lower cover Immerge the assembly under water so air loss will be easily viewed if some part is damaged or assembling is wrong If ther...

Страница 29: ...ING 4 3 1 Prism outside cleaning Removing the fixture is not necessary to clean the outer surface of the prisms and if already removed is not necessary to open it Clean the prisms surface with non abr...

Страница 30: ...from the inside Unscrew the two screws HSCS M5x12 Figure 20 n 6 and remove the mounting plate Figure 20 n 5 Then remove the old prism and the gasket carefully clean the prism seat by scraping and tak...

Страница 31: ...re 21 n 4 remove the LED module Figure 21 n 3 and the relevant reflector Figure 21 n 1 from the mounting plate unscrewing the two screw HSCS M3x12 replace the LED module it with a new one check that t...

Страница 32: ...module Figure 21 n 1 remove the LED module Figure 21 n 2 and the relevant lens array Figure 21 n 3 from the mounting plate replace the LED module it with a new one fasten the LED module and the relev...

Страница 33: ...and open it following instructions of Removing and Opening the Light Unit From the Base and proceed as follow disconnect the thermostat from the cable lead with plug and from the PCB unscrew the two s...

Страница 34: ...each O Ring must be examined as described below and replaced if necessary Any O Ring that is stretched torn has a permanent set or some other defect which would prevent it from obtaining a water tigh...

Страница 35: ...placement Remove the old O Ring from the groove and clean the flange mating surfaces and the groove scraping carefully Take care not to damage the mating surface and the bottom and sides of the groove...

Страница 36: ...on the new power supply cable lead with plug Figure 26 n 1 the new gland nut Figure 26 n 2 with teflon washer Figure 26 n 3 metal washer Figure 26 n 4 and then the new gland gasket Figure 26 n 5 so t...

Страница 37: ...rom the outside of the lower cover Figure 27 n 1 by clamping the hexagonal end section of the valve body Screw the new valve on the lower cover tightening torque is 0 35 Nm Check the valve core Figure...

Страница 38: ...fixture it s necessary to replace the LED board and unlock the monitoring device For this operation it is necessary to follow these steps remove the fixture from the base and open it following instru...

Страница 39: ...ithout the monitoring option Replace the LEDs board Wrong power PCB installed Check parts list and install the correct PCB Luminous source not working LEDS DEFECTIVE Replace the LEDs board POWER PCB D...

Отзывы: