OCEM MULTI ELECTRIC LETG Скачать руководство пользователя страница 5

 

Document UT-MT-0837_EN 

Page 5 of 29

 

 

Issue 16/10/2015 

 

 

LETG - LED ELEVATED RUNWAY GUARD LIGHT 

 

 

PRODUCT WARRANTY TERMS AND CONDITIONS 

THIS  WARRANTY  IS  THE  SOLE  WARRANTY  MADE  BY  THE  MANUFACTURER  AND  REPLACES  ANY  OTHER 
WARRANTIES,  EXPRESS,  IMPLIED  OR  STATUTORY,  INCLUDING,  BUT  NOT  BY  WAY  OF  LIMITATION,  ANY 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 
 
OCEM  -  ENERGY  TECHNOLOGY  warrants  to  the  direct  purchaser  of  the  products  manufactured  by  the 
Company that  such  products  are  free  from  defects  in  material  at  the  time of delivery  to  the  Purchaser, 
provided that no warranty is made with respect to: 
 
(a) any products that, in the Company's judgement, have been repaired or modified in such a manner as 
to damage them; 
(b)  any  products  that,  in  the  Company's  judgement,  have  been  exposed  to  negligence  or  adverse 
conditions or stored improperly; 
(c)  any  products  that  were  not  operated  or  serviced  in  accordance  with  normal  practice  and  with  the 
recommendations and specifications issued by the Company; 
(d) broken warranty seals, if any, will immediately void the warranty. 
 
The  Manufacturer's obligations  under this  warranty are  limited to  using  reasonable  efforts to  repair, or 
alternatively, replace during regular working hours those products that in the Manufacturer's judgement 
proved not be as warranted within the applicable warranty period. 
All costs of transportation of any claimed, repaired or replaced products to or from the Company's facility 
shall be borne by the Purchaser. 
The Company may demand that the claimed product be delivered to its facility at the Purchaser's expense 
in order to establish whether the claim is covered by warranty. 
The installation costs for a repaired or replacement product shall be borne by the Purchaser. Replacement 
parts provided under this warranty are covered for the remainder of the warranty period as if they were 
original equipment parts. This warranty does not cover downtime; the Company disclaims all liabilities for 
damages caused by any delays in connection with warranty service. 
 

PLEASE READ THIS DOCUMENT CAREFULLY 

Please  read  the  entire  document  carefully  before  installing,  commissioning,  operating,  servicing  or 
disposing of the equipment. 

SAFETY INFORMATION 

Use great care when working with this equipment. It is normally used in connection with or connected to 
circuits operating at dangerous voltage levels and can be fatal. 
The  following  section  contains  important  information  on  the  safety  rules  that  must  be  observed  when 
installing and operating the equipment. 
Improper use of the equipment or lack of care in applying the safety procedures and instructions provided 
in this document may create a hazard. Avoid contact with voltage or current sources. 
Do not remove the protections or safety devices for any reason whatsoever. 
 
 
 
 

Содержание MULTI ELECTRIC LETG

Страница 1: ...ANAGEMENT SYSTEM SIGNED COPY AVAILABLE AT REQUEST THIS DOCUMENT IS THE PROPERTY OF OCEM ITS CONTENTS MAY NOT BE DISCLOSED OR ALTERED WITHOUT THE WRITTEN CONSENT OF OCEM LED ELEVATED RUNWAY GUARD LIGHT...

Страница 2: ...0837_EN Page 2 of 29 Issue 16 10 2015 LETG LED ELEVATED RUNWAY GUARD LIGHT EDITIONS Date 16 10 2015 First Issue REVISION HISTORY Rev No Date Description Author Approved by LIST OF VALID PAGES From pag...

Страница 3: ...8 5 AZIMUTH AND ZENITH ANGLE ADJUSTMENT 19 6 MAINTENANCE 21 6 1 Periodic checks 21 6 2 Non scheduled maintenance 22 6 3 REPLACEMENT 22 6 3 1 Replacing lens and gasket 22 6 3 2 Replacing the LED board...

Страница 4: ...parallel circuit power supply with or without photocell 27 Figure 12 Non monitored parallel circuit power supply with switch with or without photocell 27 Figure 13 Monitored parallel circuit power sup...

Страница 5: ...s warranted within the applicable warranty period All costs of transportation of any claimed repaired or replaced products to or from the Company s facility shall be borne by the Purchaser The Company...

Страница 6: ...pen power switch upstream of line Wait until discharge time has elapsed at least 5 minutes and check for voltage before accessing the equipment RESUSCITATION Maintenance personnel must be aware of the...

Страница 7: ...l yellow LED light sources spaced 381 mm 15 apart The two light sources flash alternatively at a rate of 45 50 times per minute Aluminium housing accommodates LED boards and power supply unit U shaped...

Страница 8: ...sing current regulators and insulation transformers manufactured and or marketed by OCEM These data may vary when third party current regulators and transformers are used 2 3 Operating conditions Oper...

Страница 9: ...ty IY ICAO Yellow FY FAA Yellow TR Traffic Red Mode of operation S Series Power Circuit D 100V to 240V Parallel Power Circuit Monitoring 0 Non monitored M Monitored Photocell mode of operation D only...

Страница 10: ...ctor through U shaped frame frangible coupling and locking ring ensure to screw the locking ring all the way up to the edge of frangible coupling thread Connect fixture connector to the receptacle in...

Страница 11: ...rizon The design engineer must specify the aiming of the light so to provide a steady light intensity of at least 300 candle power at the highest intensity step when viewed from all angles between 45...

Страница 12: ...UT MT 0837_EN Page 20 of 29 Issue 16 10 2015 LETG LED ELEVATED RUNWAY GUARD LIGHT Figure 4 Horizontal and vertical aiming indexes LEFT VERTICAL AIMING INDEX HORIZONTAL AIMING INDEX RIGHT VERTICAL AIMI...

Страница 13: ...6 1 Periodic checks Routine inspection cleaning and maintenance intervals vary according to type location and use of the equipment A maintenance schedule targeted to required service standards should...

Страница 14: ...eplacing the LED board 1 Unscrew the four screws of the rear panel 2 Disconnect the two cables from connector J1 of board F266 3 At the front end unscrew the four screws of the locking ring the lockin...

Страница 15: ...e terminal of the monitoring device if fitted and unscrew the screw to which the earth cable with eyelet terminal is connected 3 Unscrew the outer nut of the cable gland that holds the power supply ca...

Страница 16: ...circuit Check to ensure that RMS current is between 2 8 and 6 6 A using an amperemeter For parallel circuit Check for proper 100 240Vac voltage Power supply cables of board damaged Replace damaged cab...

Страница 17: ...MT 0837_EN Page 25 of 29 Issue 16 10 2015 LETG LED ELEVATED RUNWAY GUARD LIGHT 8 WIRING DIAGRAMS Figure 7 Non monitored series circuit power supply Figure 8 Non monitored series circuit power supply...

Страница 18: ...Document UT MT 0837_EN Page 26 of 29 Issue 16 10 2015 LETG LED ELEVATED RUNWAY GUARD LIGHT Figure 9 Monitored series circuit power supply Figure 10 Monitored series circuit power supply with switch...

Страница 19: ...of 29 Issue 16 10 2015 LETG LED ELEVATED RUNWAY GUARD LIGHT Figure 11 Non monitored parallel circuit power supply with or without photocell Figure 12 Non monitored parallel circuit power supply with s...

Страница 20: ...28 of 29 Issue 16 10 2015 LETG LED ELEVATED RUNWAY GUARD LIGHT Figure 13 Monitored parallel circuit power supply with or without photocell Figure 14 Monitored parallel circuit power supply with switc...

Страница 21: ...Document UT MT 0837_EN Page 29 of 29 Issue 16 10 2015 LETG LED ELEVATED RUNWAY GUARD LIGHT Figure 15 Wiring diagram for connection of monitored LETG to transformer...

Отзывы: