background image

 

Document UT-MT-0779_EN 

Page 37 of 37 

 

Edition 23/04/2019 

Supersedes edition 06/03/2019 

 

LED INSET RUNWAY EDGE LIGHT LIRE 
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE 

 

6

 

SPARE PARTS 

CODE 

DESCRIPTION 

RISL20001  Kit Mounting Gaskets 
RISL20005  Kit Reflectors with screws 
RISL20006  Artic Kit for unidirectional dome 
RISL20007  Artic Kit for bidirectional dome, with 1 input 
RISL20008  Artic Kit for bidirectional dome, with 2 input 
RISL20011  Unidirectional dome 
RISL20012  Unidirectional dome with Artic Kit 
RISL20021  Bidirectional dome 
RISL20022  Bidirectional dome with Artic Kit 
RISL20023  LED Module F186 WHITE 
RISL20025  LED Module F248 RED 
RISL20026  LED Module F186 YELLOW 
RISL20029  LED Module F248 GREEN 
RISL20033  Kit Prism with gasket 
RISL20040  Lower Cover 12” 1I/2O with monitoring, configurations WM and YM 
RISL20041  Lower Cover 12” 1I/2O without monitoring, configurations WM and YM 
RISL20044  Lower Cover 12” 1I/2O with monitoring, configuration RM and GM 
RISL20045  Lower Cover 12” 1I/2O without monitoring, configuration RM and GM 
RISL20054  Lower Cover 12” 1I/4O with monitoring, configurations WW, WY and YW 
RISL20055  Lower Cover 12” 1I/4O without monitoring, configurations WW, WY and YW 
RISL20056  Lower Cover 12” 1I/4O with monitoring, configuration RR 
RISL20057  Lower Cover 12” 1I/4O without monitoring, configuration RR 
RISL20058  Lower Cover 12” 1I/4O with monitoring, configurations WR, RW, YR, RY, YG, GY 
RISL20059  Lower Cover 12” 1I/4O without monitoring, configurations WR, RW, YR, RY, YG, GY 
RISL20068  Lower Cover 12” 2I/4O with monitoring, configurations WW, WY and YW 
RISL20069  Lower Cover 12” 2I/4O without monitoring, configurations WW, WY and YW 
RISL20070  Lower Cover 12” 2I/4O with monitoring, configurations WR, RW, YR, RY, YG, GY 
RISL20071  Lower Cover 12” 2I/4O without monitoring, configurations WR, RW, YR, RY, YG, GY 
RISL20072  Lower Cover 12” 2I/4O with monitoring, configuration RR 
RISL20073  Lower Cover 12” 2I/4O without monitoring, configuration RR 

RISLX0002  Pressure valve 

RISLX0003  Grease for O-Ring gaskets (400 gr) 
RISLX0004  Screws and O-Ring gasket for fixture fixing on base 
RISLX0006  Unipolar power supply cable lead with plug L=0.6 m 
RISLX0007  Anaerobic adhesive for fillets 
RISLX0008  L-823 cable with gland nut for shallow bases 

 

Содержание LIRE Series

Страница 1: ...SIGNED SINCE IT IS FILED AND DELIVERED BY MEANS OF THE AUTOMATIC KNOWLEDGE MANAGEMENT SYSTEM IT CAN BE SIGNED ON REQUEST THIS DOCUMENT AND THE DATA CONTAINED HERE IN IS PROPRIETARY PROPERTY AND SHALL...

Страница 2: ...the applicable warranty period All costs of transportation of Products claimed not to be warranted and of those repaired or replaced to or from the facility of the Company shall be borne by Purchaser...

Страница 3: ...the unit opened the main circuit breaker and removed the supply to the unit by opening the circuit breaker switch on the distribution board at the beginning of the supply line Then wait discharge time...

Страница 4: ...parts and added relevant attachment 03 11 2014 New address of the Company Updated the P N identification 04 05 2018 Added ground wire specifications REVISIONS Index Date Description Edited by Approved...

Страница 5: ...UTTING 17 3 1 1 Scheme of Light Configurations 18 3 2 INSTALLING THE SHALLOW BASE 18 3 3 INSTALLING THE LIGHT UNIT ON L 868 BASE SIZE B 23 3 4 SECONDARY WIRING 23 4 MAINTENANCE 24 4 1 MAINTENANCE PROG...

Страница 6: ...plete P N identification 13 Figure 8 Standard 12 shallow base 14 Figure 9 Pavement Boring Sawcutting and Joint Intersection Details 17 Figure 10 Example of Light Unit Configuration 18 Figure 11 Gasket...

Страница 7: ...a shallow base receptacle The fixture is waterproof and designed to withstand aircraft impact and roll over loads without damage The fixture can be bidirectional type bidirectional dome equipped with...

Страница 8: ...y the beam 4 Through hole for light unit fastening Figure 1 12 Dome outside view 2 1 2 Optical Assembly The optical assembly consists of four prisms Figure 5 n 13 with relevant gaskets Figure 5 n 12 k...

Страница 9: ...600V cable A suitable valve is outside mounted for the leakage test Watertightness between fixture and shallow base is ensured by means of an O Ring separately supplied to be placed on the relevant s...

Страница 10: ...3 Grounding cable hole 4 Letter A and B for cable lead identification 5 Cable lead entry Figure 2 Lower Cover Outside View The same colour painting is provided outside on the lower cover See Complete...

Страница 11: ...19 LED INSET RUNWAY EDGE LIGHT LIRE INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE LED LED POWER SUPPLY POWER SUPPLY LED LED LED LED POWER SUPPLY POWER SUPPLY LED LED LED LED 1 In 1 Out 1 In...

Страница 12: ...E 1 Dome 1 2 O Ring for dome external 1 3 O Ring for dome internal 1 4 O Ring for lower cover 1 5 Arctic kit heater 1 2 6 Reflector with hardware 4 7 LED module with accessories 4 8 Lower cover 1 9 Va...

Страница 13: ...Compliance I ICAO 60 m S ICAO 45 m F FAA Colour Side L Side R W White Y Yellow G Green FAA R Red M Blank unidirectional dome Cables and connectors 1P One Plug 2P Two Plugs Monitoring 0 Without Monitor...

Страница 14: ...to the cable entry The shallow base is designed for cementing in place by means of epoxy resin in a hole drilled in the pavement The fixture has to be fastened to the base by means of six hex cap scr...

Страница 15: ...lso few lights in the series circuit isolation transformers of smaller size can be used respect to those used with the equivalent fixtures equipped with halogen lamps The input circuit is protected ag...

Страница 16: ...features is essential when the monitoring option is required events recording not volatile memory for diagnostic purposes PC operator interface through serial connection this features allows to calibr...

Страница 17: ...and depth are maintained within the specified limits All surfaces of the recess must be clean and dry If any of these surfaces is damp it is desirable that it be dried and blown clean with a compresse...

Страница 18: ...RE INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE 3 1 1 Scheme of Light Configurations Figure 10 Example of Light Unit Configuration 3 2 INSTALLING THE SHALLOW BASE Two different installation...

Страница 19: ...lamping lug ATTENTION Insulate each splice carefully using either heat shrinkable insulating tubing properly applied or at least three layers of plastic electrical insulating tape applied with half ov...

Страница 20: ...osition When the shallow base is in its final position the conduit s must be properly jointed to the hole s provided on the shallow base This these hole s can be provided either on the wall either on...

Страница 21: ...LED INSET RUNWAY EDGE LIGHT LIRE INSTRUCTION MANUAL FOR USE INSTALLATION AND MAINTENANCE 1 O Ring around the dome 2 12 shallow base 3 O Ring between fixture and base Figure 11 Gaskets for 12 shallow...

Страница 22: ...notch with the mark on the pavement 3 Circular level 4 Screws and spacers for the jig mounting 5 Lobe knob for positioning jig levelling 6 Shallow base notches aligned with the notch on the jig 7 12 s...

Страница 23: ...connection Then press the fixture firmly and evenly by hand onto the base flange Secure the fixture to the base by using the six locking screws complete with washers supplied with the base One drop o...

Страница 24: ...EFORE ANY MAINTENANCE INTERVENTION MAKE SURE THE POWER SUPPLY BE SWITCHED OFF DO NOT OPERATE ON LIVE PARTS LED lighting fixtures do not require frequent maintenance With well run installations and han...

Страница 25: ...Recommended snow removal techniques are described in Airport Service Manual ICAO Part 9 Airport Maintenance Practices or FAA AC 150 5200 30 4 2 REMOVING AND OPENING THE LIGHT UNIT FROM THE BASE 4 2 1...

Страница 26: ...unt the lower cover on the dome and fasten it by means the six screws flat CSS TORX M5x10 Figure 16 n 1 One drop of anaerobic adhesive lower type e g LOXEAL 24 18 should be applied to the screws befor...

Страница 27: ...O Ring between dome and lower cover 4 O Ring around the dome 5 Lower Cover 6 12 Shallow base 7 O Ring between fixture and 12 Shallow base Figure 18 Fixture Gaskets 4 3 PRIMS CLEANING 4 3 1 Prism outs...

Страница 28: ...pieces of the old prism and all accumulated debris from the inside Unscrew the two screws HSCS M5x12 Figure 20 n 6 and remove the mounting plate Figure 20 n 5 Then remove the old prism and the gasket...

Страница 29: ...LED module Figure 21 n 3 and the relevant reflector Figure 21 n 1 from the mounting plate unscrewing the two screw HSCS M3x12 replace the LED module it with a new one check that the thermal interface...

Страница 30: ...the power supply connector s to the LED module s Reassembly the fixture following instructions of paragraph Closing the Fixture Leakage Test and Reinstalling the fixture 4 7 ARCTIC KIT REPLACEMENT 4...

Страница 31: ...er the new heater cable on the thermostat terminals protect the soldered joint from moisture with a piece of suitable heat shrink tubing clean the heater dome area apply silicon thermal paste like Wac...

Страница 32: ...t be replaced with a new O Ring Remove the fixture from the base and open it following instructions of Removing and Opening the Light Unit From the Base Light assembly is equipped with the following g...

Страница 33: ...re important in obtaining a complete seal TIGHTENING TORQUE lower cover flat CSS TORX M5x16 2 5 Nm fixture locking screw 35 Nm for shallow base 35 Nm for L 868 base size B 4 9 CABLE LEAD WITH PLUG 4 9...

Страница 34: ...e 26 n 1 by clamping the hexagonal end section of the valve body Screw the new valve on the lower cover tightening torque is 0 35 Nm Check the valve core Figure 26 3 is tightened to the valve body Fig...

Страница 35: ...ration it is necessary to follow these steps remove the fixture from the base and open it following instructions of Removing and Opening the Light Unit From the Base replace the LED module following i...

Страница 36: ...onitoring option Replace the LEDs board Wrong power PCB installed Check parts list and install the correct PCB Luminous source not working LEDS DEFECTIVE Replace the LEDs board POWER PCB DEFECTIVE Rep...

Страница 37: ...configuration RM and GM RISL20054 Lower Cover 12 1I 4O with monitoring configurations WW WY and YW RISL20055 Lower Cover 12 1I 4O without monitoring configurations WW WY and YW RISL20056 Lower Cover 1...

Отзывы: