13

of the state.
3. Install and use the monitor in the indoor safety area without explosive gas
environment.
4. Correct installation and reliable grounding to improve anti RFI interference
and anti EMI interference capability.
5. Ensure that the test gas concentration does not exceed the gas range of the
monitor.
6. Installation, use and maintenance of products shall comply with product
specifications, GB3836.13-1997 "Electrical equipment for explosive gas
environment Part 13: Maintenance of electrical equipment for explosive gas
environment", GB3836.15-2000 "Electrical equipment for explosive gas
environment Part 15: Electrical installation in dangerous places (except in coal
mines) The relevant provisions of GB3836.16-2006 "Electrical equipment for
explosive gas environment Part 16: Inspection and maintenance of electrical
devices (except coal mines)" and GB50257:1996 "Code for construction and
acceptance of electrical devices for explosive and fire dangerous environments in
electrical equipment installation works".

4.2 Installation

Install type: Pole mounted installation
Installation accessories: two groups of hoops, according to the size of the hoop,
the hoop size can be selected as 76 diameters/89 diameters/114 diameters; 4*M10
installation screws, Pole :1pc.

Steps:
1) Install and secure the holding pole in suitable place.
2) Install hoop and related accessories according to the illustration.
3) Install the instrument on the holding pole, tighten the screws, fix it safely and
prevent the occurrence of dangerous situations such as slide.

Содержание AQM-09

Страница 1: ...AQM 09 Air quality monitor system Operating Manual Henan Oceanus...

Страница 2: ...he above mentioned manual the operator shall be responsible for the reliability of the instrument And this company is not responsible for the warranty 4 This machine is non explosion proof equipment P...

Страница 3: ...is a new product which can monitor the air quality via the value of O3 SO2 NO2 CO PM2 5 PM10 etc The target value is converted into voltage signal by operational amplifier circuit and then filtered t...

Страница 4: ...safe and reliable Please do not put this monitor in the high temperature moist or strong static environment Please do not install monitor in a large quantity of dust salt and metal powder Please do n...

Страница 5: ...aste disposal station or yard mining industry heavy industry airport wharf railway construction site Residential quarters schools hospitals Environmental impact assessment and source apportionment II...

Страница 6: ...Humidity 90 RH power 20W Humidity 90 RH power 40W Dimensions 500 400 300mm Protection grade IP55 Range PM2 5 0 1000 ug m3 PM10 0 1000 ug m3 Sampling flow rate 1 3L min 0 15 Sampling time Adjustable de...

Страница 7: ...ne monitoring monitoring system HJ_T 524 2009 air pollutant name code Technical requirements of HJ 907 2017 automatic monitoring system for environmental noise HJ663 2012 technical specification for e...

Страница 8: ...40 70 degrees Celsius The high precision ADC data acquisition system can monitor pollutants at ppb level The dynamic heating dehumidification control is adopted to remove the influence of water mist...

Страница 9: ...d other ways any installation mode is solid and reliable and can resist instantaneous 12 level wind III Function introduction Cyclone type physical cutter The particle concentration was measured by la...

Страница 10: ...value of particles After coefficient conversion the dust concentration value is output in real time through data interface With cyclone physical cutter and PID real time temperature control system the...

Страница 11: ...11 3 3 System From the main interface choose the system you can check and modify system setting...

Страница 12: ...rface choose the user you can calibrate the dust value the password is 123456 IV Installation 4 1 Installation notes 1 When installing products please refer to the relevant literature to meet the basi...

Страница 13: ...n coal mines The relevant provisions of GB3836 16 2006 Electrical equipment for explosive gas environment Part 16 Inspection and maintenance of electrical devices except coal mines and GB50257 1996 Co...

Страница 14: ...al and industry Fault Possible cause Solve Can t start to work Unconnected power supply Check whether the power line is inserted Can t connect the platform The SIM card insert wrong side Check whether...

Страница 15: ...ronment in the warranty period the company would not be responsible for it If the machine cannot work because of the quality problem our company would maintain or change in free for the user The compa...

Страница 16: ...16 Henan Oceanus Import Export Co Ltd Email info china oceanus com Web http china oceanus com...