NORM SURF ALT 3
, information includes (Fig. 6):
> Current O2 (%) with O2SAT icon
> PO2 alarm value set (ATA) with PO2 and MAX icons
> FO2 set for Gas 1 with FO2 icon
> NX icon
> (PZ+) icon, if selected, no icon if Dsat is selected
> CF icon, if Conservative Factor is set On
> Gas 1 icon, default in Surface Mode
• A (< 2 sec) to access Fly/Sat.
• A (hold) to scroll forward through Menu items.
• M (< 2 sec) to step back to ALT 2.
• S (press) to activate SmartGlo Backlight.
FLY/SAT TIME
Time to Fly is a countdown timer that begins counting down from 23:50 to 0:00 (hr:min)
10 minutes after surfacing from a dive (NORM, GAUG, or FREE).
Time to Desaturate, also a countdown timer, provides calculated time for tissue desatura-
tion at sea level taking into consideration the Conservation Factor setting. It also begins
counting down 10 minutes after surfacing from a dive (NORM or FREE), counting down
from 23 to 10 (hr only), then 9:59 to 0:00 (hr:min).
When the SAT countdown reaches 0:00, which will generally occur prior to the FLY count-
down reaching 0:00, it will remain on the display until the FLY countdown reaches 0:00.
Fig. 6 - NORM SURF ALT 3
(only if Nitrox)
Содержание VEO 3.0
Страница 1: ......
Страница 2: ......
Страница 9: ...9 Welcome to OCEANIC and THANK YOU for choosing the VEO 3 0 FEATURES AND FUNCTIONS...
Страница 19: ...19 NORM SURFACE MENU MODES...
Страница 49: ...49 DIVE MODE FEATURES...
Страница 57: ...57 NORM DIVE MODES...
Страница 73: ...73 DIGITAL GAUGE MODE...
Страница 79: ...79 FREE DIVE MODE...
Страница 91: ...91 REFERENCE...
Страница 103: ...103 TECHNICAL DATA...
Страница 111: ...111...
Страница 112: ......