This manual is intended as a guide to replace the battery in the
Oceanic ProPlus X dive computer module.
This service must be performed in a dry (maximum 40% relative
humidity) and clean environment at room temperature (56-78°F
/ 18-25°C).
Safety Precautions
This manual provides step by step instructions for replacing
the battery of the Oceanic ProPlus X dive computer. It is
recommended that all steps are followed in the order given.
Read each section completely
PRIOR
to beginning the work
described in that section.
Pay close attention to all WARNINGS, CAUTIONS and NOTES
that are intended to draw your attention to items of importance
.
Definitions of terms:
!
WARNING
WARNING is used before a procedure that could
potentially result in serious injury or death if
performed incorrectly.
!
CAUTION
CAUTION is used in connection with a procedure
that may cause damage to the equipment.
NOTE
NOTE is used in connection with a procedure
that requires special attention.
INTRODUCTION
NOTE
Do not open any seals if not necessary. After opening a
seal, always replace the O-ring.
Battery replacement is necessary when the battery replacement
message is displayed on the computer screen and/or the user
is experiencing shortened battery life per charge.
Handling & Storage of Parts
Spare parts must be stored in a clean and dry environment.
Ensure parts are not exposed to dust or other contaminants.
Take special care of sealing gaskets, O-rings, and electronic
components.
NOTE
The battery kit must be stored in original packaging until
being used in repair.
GENERAL PROCEDURES
SERVICE TOOLS
General Tools
• 3/32” Allen key
• Grounding strap
• Work station (grounded)
• Orange stick or spudger
• Silicone grease
• Lint-free microfiber cloth