Oceanic PROPLUS X Скачать руководство пользователя страница 36

36

PROPLUS X OPERATING MANUAL

© Pelagic, 2016

Doc. No. 12-5655-r01 (8/19/16)

SET BRIGHTNESS

GAS SWITCH

MORE DATA

DS PREVIEW

DIVE MENU

NORM

80 %

(>) TO SET

ADJUST 

SELECT TO

BY %

CONTROLS

 

scroll up

 

scroll down

 

to Dive Main

 

to Set

DIVE MENU

Set Brightness, More Data, Gas Switches, and Deep Stop Preview are all accessed from the Dive Menu.

1: SET BRIGHTNESS

The level (%) of screen brightness can be adjusted to optimize screen appearance in different lighting conditions or to conserve battery 

power.

   NOTE:  During a Low Battery Warning or Alarm condition, the level will be limited to 60% maximum.

SET BRIGHTNESS

GAS SWITCH

MORE DATA

DS PREVIEW

D2B

ADJUST

BRIGHTNESS

20 %

VALUE

^

 - INCREASE

v

 - DECREASE

>

 - SAVE

(<) BACK TO MENU

CONTROLS

 

increase value

 

decrease value

 

to Dive Menu

 

to save setting

2: MORE DATA

This screen reveals additional dive data.

NORM

MORE DIVE DATA

NDC

DIVE TIME

MAX DEPTH

TIME OF DAY

GAS 1  FO2

TEMPERATURE

GAS 1  PO2 AL

CURRENT PO2

O2 SAT

= 13 

min

= 37 

min

= 132 

FT

= 11:46

 AM

= 74°

F

= 32

%

= 1.40
= 24

%

= 0.84

(<) BACK TO MENU

CONTROLS

 

to Dive Menu

Содержание PROPLUS X

Страница 1: ...1 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 PROPLUS X DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...IVE TIME 27 4 TLBG TISSUE LOADING BAR GRAPH 28 5 DTR DIVE TIME REMAINING 28 6 TURN PRESS 28 7 LOW PRESS 29 SET UTILITIES 29 1 WATER TYPE 29 2 UNITS 30 3 DEEP STOP 30 4 SAFETY STOP 30 5 ALGORITHM 31 6...

Страница 3: ...stered and unregistered trademarks trade names and service marks of Pelagic All rights are reserved PATENT NOTICE U S Patents have been issued or applied for to protect the following design features A...

Страница 4: ...4 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 Welcome to OCEANIC and THANK YOU for choosing the ProPlus X...

Страница 5: ...5 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GETTING STARTED...

Страница 6: ...ferences in the ProPlus X settings Additionally the ProPlus X screen will sleep after 2 minutes of inactivity to conserve power Pressing any button will wake the screen up again CHARGING THE BATTERY U...

Страница 7: ...ll release from the console Assembly Visually inspect the fittings and connection O ring for damage corrosion or deterioration WARNING If damage corrosion or deterioration is found return your ProPlus...

Страница 8: ...CE TIME FT OR M DEPTH FEET OR METERS DIVE DIVE NUMBER PSIOR BAR GAS PRESSURE GTR GAS TIME REMAINING NDC NO DECOMPRESSION TIME OTR OXYGEN TIME REMAINING EDT ELAPSED DIVE TIME DS DEEP STOP TRIGGERED 54...

Страница 9: ...ons and access specific information They are also used to enter settings and acknowledge the audible alarm Pressing different combinations of these buttons will navigate through different menus and op...

Страница 10: ...10 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 HOME MENU...

Страница 11: ...een displays personal information Information must be entered using the Diverlog interface PROPLUS X INFO Information displayed on the DC Info screen should be recorded and kept with your sales receip...

Страница 12: ...to set the Brightness level and a power saving Auto Dim feature A Set Brightness The level of screen brightness can be adjusted to optimize screen appearance in different lighting conditions or to co...

Страница 13: ...ue 2 BLUETOOTH Within this screen the Bluetooth may be turned on or off When Bluetooth is turned on it will operate in sniffing mode searching for compatible devices while on the surface Comunication...

Страница 14: ...e Format You can choose between D M Day Month and M D Month Day BACK TO SET MENU DATE FORMAT DATE TIME TIME FORMAT SET DATE FORMAT D M VALUE INCREASE v DECREASE SAVE CONTROLS toggle setting toggle set...

Страница 15: ...ue 4 CALIBRATE COMPASS You may need to calibrate the compass from time to time to compensate for any magnetic changes new dive location or other surround ing changes Follow the prompts to calibrate th...

Страница 16: ...ce for the new entries Dives are numbered starting with 1 each time Norm or Gauge mode is activated After 24 hours elapse with no dive the first dive of the next period of operation is called Dive 1 I...

Страница 17: ...o Log Data 1 Data 3 NOTE If the record is a Gauge dive the message GAUGE DIVE NO DATA will be displayed on the Log Data 3 screen HISTORY History is a summary of basic data recorded during all Norm and...

Страница 18: ...18 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 DIVE FEATURES...

Страница 19: ...125 FT NDC NORM 74 F 12 36 PM 70 54 TL 2340 PSI D1B v TO MENU TO COMPASS 47 EDT 21 GTR OTR OXYGEN TIME REMAINING When set for nitrox operation O2 SAT Oxygen Saturation during a dive is displayed on t...

Страница 20: ...derably more conservative than the DSAT version especially at shallower depths To create even greater margins of safety with respect to decompression a Conservative Factor as well as Deep and Safety S...

Страница 21: ...the Safety Stop or choose to ignore it LOW BATTERY WARNING DO NOT dive with a low battery Charge the battery before diving if your ProPlus X indicates the Battery Low Warn ing or Alarm Warning Level...

Страница 22: ...tuations shall activate the Alarm 1 beep per sec for 10 sec Conditional Violation Delayed Violations 1 2 3 Ascent Rate too fast 100 bar graph red color PO2 increases to 20 Alarm Set Point and at the A...

Страница 23: ...23 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM SURFACE MODE...

Страница 24: ...ettings Press the Right button to choose menus or options from the Main Menu when available TO SET SET BRIGHTNESS LAST DIVE DATA PLAN MORE DATA SET GAS SET ALARMS SET UTILITIES SET PREVIEW VIEW PREVIE...

Страница 25: ...NTROLS to Main Menu PLAN This mode calculates dive depth and time limits To do so it accounts for any residual nitrogen oxygen surface intervals the programmed gas mix and PO2 alarm setting Either NDC...

Страница 26: ...s played as an FO2 setting until 24 hours elapse after the last dive NOTE When FO2 is set for AIR oxygen related data such as PO2 O2 will not be displayed at any time during the dive on the surface or...

Страница 27: ...MENU 130 FT VALUE INCREASE v DECREASE SAVE CONTROLS increase value decrease value to Alarms Set Menu to save value AR 0 DS GAS 1 AIR FO2 PO2 12 130 FT NDC 54 TL 1031 PSI v TO MENU TO COMPASS 39 21 EDT...

Страница 28: ...ude OFF or 5 20 min of dive time remaining AUDIBLE DEPTH EDT TLBG DTR TURN PRESS LOW PRESS SET DTR ALARM BACK TO MENU 5 min VALUE INCREASE v DECREASE SAVE CONTROLS increase value decrease value to Ala...

Страница 29: ...2 PO2 46 FT 37 NDC 54 TL 400 PSI v TO MENU TO COMPASS 53 EDT 11 GTR LOW PSI Low Press Alarm Triggered SET UTILITIES Within the Utilities set menu you can customize the following seven operational func...

Страница 30: ...ature can be set ON or OFF UNITS WATER TYPE DEEP STOP SAFETY STOP ALGORITHM CONSERVATIVE SAMPLE RATE DEEP STOP SET BACK TO MENU SETTING TOGGLE v TOGGLE ON SAVE CONTROLS toggle setting toggle setting t...

Страница 31: ...decreases to 0 00 UNITS WATER TYPE DEEP STOP SAFETY STOP ALGORITHM CONSERVATIVE SAMPLE RATE SET ALGORITHM BACK TO MENU SETTING TOGGLE v TOGGLE Z SAVE CONTROLS toggle setting toggle setting to Utiliti...

Страница 32: ...e ProPlus X s onboard Log that have already been overwritten in the PC Download Partition Choosing a longer Sample Rate interval will consume less memory per dive Remember to download your dives more...

Страница 33: ...PO2 AL DEPTH AL EDT AL DTR AL WATER TYPE SAFETY STOP AIR 32 1 40 120FT 50min 5min SEA 15FT 3min BACK TO MENU CONTROLS to Main Menu VIEW PREVIEW Upon accessing this screen from the Norm Main Menu the...

Страница 34: ...34 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM DIVE MODE...

Страница 35: ...ates and describes an uneventful dive in terms of safety Alarms are described in the Complications section of this chapter WARNING Before diving with the ProPlus X take time to familiarize yourself wi...

Страница 36: ...n appearance in different lighting conditions or to conserve battery power NOTE During a Low Battery Warning or Alarm condition the level will be limited to 60 maximum SET BRIGHTNESS GAS SWITCH MORE D...

Страница 37: ...O2 value 1 6 PO2 a warning will be displayed Though the diver will not be prevented from chosing the gas If the diver proceeds to select said gas a high PO2 alarm will then trigger NORM GAS SWITCH AIR...

Страница 38: ...l be displayed and count down to 0 00 as long as you stay within 10 ft 3 ft above or below the stop See Deep Stop in the Dive Features chapter for further details NOTE The ProPlus X does not penalize...

Страница 39: ...8 FT 100 TL 1453 PSI v TO MENU TO COMPASS 2 32 DECO STOP GTR FT DECO ENTRY DECOMPRESSION STOP MAIN Decompression deco Stop Main will display upon ascending to within 10 ft 3 m below the Deco Stop dept...

Страница 40: ...ow and DOWN TO STOP message continues to flash until descending below the required Stop Depth If the Delayed Violation 1 status is ignored the ProPlus X will enter Delayed Violation 1 Surface mode for...

Страница 41: ...OLATION SURF TL 1067 PSI v TO MENU TO COMPASS 5 DIVE GTR VIOLATION GAUGE MODE VGM ON THE SURFACE The message VIOLATION is displayed until 24 hours elapse with no dives During that 24 hours VGM lockout...

Страница 42: ...enced they alternate with Deco Stop Time until PO2 decreases below 1 60 AR 0 GAS 1 32 FO2 PO2 1 60 132 FT 100 TL 1299 PSI v TO MENU TO COMPASS 11 GTR ALARM PO2 1 60 AR 20 GAS 1 32 FO2 PO2 1 20 75 FT 5...

Страница 43: ...UP O2 100 ALARM DURING DECO If O2 SAT reaches the Alarm level the audible alarm sounds and the O2 SAT value will flash in the middle of the screen When the au dible alarm is silenced the message O2 S...

Страница 44: ...44 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GAUGE MODE...

Страница 45: ...VE DATA MORE DATA SET ALARMS SET UTILITIES VIEW PREVIEW GAUGE MAIN MENU FOR ACCESS LATEST DIVE DATA TO VIEW DATA CONTROLS scroll up scroll down to Surface Main to access INITIATING A DIVE With the Pro...

Страница 46: ...46 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NOTE All other Gauge mode dive functions are similar to Norm Mode See the Norm Dive Mode chapter for further details...

Страница 47: ...47 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 COMPASS MODE...

Страница 48: ...12 36 74 F PM 70 22 sec TO SURF MAIN 54 TL SURF 1 56 147 COMPASS DISPLAY ICONS 1 COMPASS MODE 2 DEPTH OR SURFACE TIME 3 HEADING CORRECTION ARROW 4 HEADING MARKER 5 TIME OUT COUNTDOWN 6 HEADING DEGREE...

Страница 49: ...unction is found in the Home Setup Menu see p 15 NOTE Magnetic declination or variation measures the angle between the Earth s magnetic north and true north The declina tion value for any region can b...

Страница 50: ...everse the reference set the reciprical heading SET HEADING 74 F REF 320 12 36 PM 1 56 70 22 sec 54 TL ROTATE KEEP LEVEL TO LOCK SURF 320 CONTROLS to North Mode to Norm Gauge Main to apply earmark to...

Страница 51: ...51 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 REFERENCE...

Страница 52: ...e of debris or obstructions To dissolve salt crystals use lukewarm water or a slightly acidic bath 50 white vinegar 50 fresh water After removal from the bath place the ProPlus X under gently running...

Страница 53: ...that the Wet Contacts are bridged When diving in high altitude waters from 3 001 to 14 000 feet 916 to 4 270 meters the ProPlus X automatically adjusts to these conditions pro vidingcorrected Depth a...

Страница 54: ...54 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 TECHNICAL DATA...

Страница 55: ...0 05 0 05 0 05 0 05 150 0 08 0 06 0 06 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 160 0 07 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 170 0 07 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0 0...

Страница 56: ...03 0 03 0 03 0 03 180 0 05 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 190 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 00 Z BASED NDLS HR MIN METRIC Altitude 0 916 1221 1526 1...

Страница 57: ...splays Dives 1 to 24 Resets to Dive 1 upon diving after 24 hours with no dives Dive Log Mode Stores max 24 entries per day 99 entries in memory for viewing After 24 dives in one day or 99 dives overal...

Страница 58: ...Interval 0 00 to 23 59 hr min 1 minute Dive No 0 to 24 1 Elapsed Dive Time 00 to 599 min 1 minute FO2 Set Points Air 21 to 100 1 PO2 Value 0 00 to 5 00 ATA 01 ATA O2 Saturation 0 to 100 1 Dive Time R...

Страница 59: ...xygen FORM Format date time FPM Feet Per Minute FT Feet depth GTR Gas Time Remaining HR Hour M Meters depth MAX Maximum M D D M Month Day Day Month MIN min Minutes time MPM Meters Per Minute NDC No De...

Страница 60: ...b www OceanicWorldwide com E mail hello oceanicusa com OCEANIC NORTHERN EUROPE Augsburg Germany Tel 49 0 821 810342 0 Fax 49 0 821 810342 29 Web www oceanic de E mail office oceanic de OCEANIC ITALY G...

Страница 61: ...61 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 ProPlus X DIVE COMPUTER OPERATING MANUAL...