Oceanic PRO PLUS 3 Скачать руководство пользователя страница 13

13

PRO PLUS 3 OPERATING MANUAL

© 2002 Design, 2012

Doc. No. 12-5332-r01 (11/19/12)

SET GAS

 (

NORM FO2 & PO2 ALARMS)  

Sequence >> Gas 1 >> Gas 2 >> Gas 3 >> FO2 50% Default.

With the FO2 50% Default selection set Off, the Pro Plus 3 will remain set at the last FO2 set point for that period of activation.

 

  

When the FO2 50% Default is set On and FO2 is set for a numerical value, 10 minutes on the surface after that dive the FO2 will 

be displayed as 50 and further dives will be calculated based on 50% O2 for oxygen calculations and 21% O2 for Nitrogen 

calculations (79% Nitrogen), unless FO2 is set before the dive. 

FO2 will continue to reset to the FO2 50% Default after subsequent repetitive dives until 24 hours elapse after the last dive, or the 

FO2 50% Default is set Off.

FO2 set to Air

The default FO2 settings for Gas 1, 2, and 3 each new activation period will be Air with Gas 2 and 3 also set Off.  

When FO2 is set for Air - 

>  calculations are the same as when FO2 is set for 21%.  

>  it will remain set for Air until set for a numerical FO2 value (21 to 50%).

>  O2 data (such as PO2, O2%) will not be displayed at any time during the dive, on the surface, or during the PDPS.  

>  MODs (Max Operating Depths) affected by the PO2 limit will not be displayed on the FO2 set screen.

>  internally, it will keep track of O2 data in case FO2 is subsequently set for Nitrox for repetitive dives.

FO2 set for Nitrox

When FO2 is set for a numerical value (21 to 100%), the dive is considered Nitrox and the NX icon will be displayed.  

>  The Air option will not be displayed as a FO2 set selection until 24 hours elapse after the last dive.

Set FO2 GAS LEAD-IN,

 information includes (Fig. 15):

>  Graphics Goto Set GAS.

•  A (< 2 sec) to step forward to Set Alarms Lead-in.

•  S (< 2 sec) to access Set Gas 1.

Set Gas 1,

 information includes (Fig. 16, 17):

>  Max Depth allowed for the PO2 alarm set with MAX and FT (or M) icons, blank if Air.

>  NX, Z+ (or DSAT), CF icons - those that apply.

>  Gas 1 icon.

>  PO2 alarm value set (ATA) for Gas 1 with icon, blank if Air.

>  Graphic Air or FO2 Nitrox value, flashing, with icon.

>  Graphic GAS 1.

•  A (hold) to scroll upward through FO2 set points at a rate of 8 per second from Air (default) to 21 through 100 (%) in 

increments of 1%.

 > The scroll will stop when A is released, or at 32, then 50, then 80%, (even if A is held depressed).  Press/hold A again will 

resume the scroll through 100, then stop at Air (or 21%).

•  A (< 2 sec) to step upward through FO2 set points one at a time.

•  S (< 2 sec) to save the FO2 setting and flash the PO2 digits if Nitrox, or access Set Gas 2 if Air.

•  S (2 sec) to revert to Set Gas Lead-in.

•  A (< 2 sec) to step upward through PO2 Alarm set points one at a time from 1.00 to 1.60 in increments of .05.

•  S (< 2 sec) to save the PO2 Alarm setting and access Set Gas 2.

•  S (2 sec) to revert to Set Gas Lead-in.

Set Gas 2 (3 similar),

 information includes (similar to Fig. 16, 17):

>  Max Depth allowed for the PO2 alarm set with MAX and FT (or M) icons, blank if OFF or Air.

>  NX, Z+ (or DSAT), CF icons - those that apply.

>  Gas 2 icon.

>  PO2 alarm value set (ATA) for Gas 2 with icon, blank if OFF or Air.

>  Graphic OFF* or Air or FO2 Nitrox value, flashing, with icon.

>  Graphic GAS 2.

*OFF prevents the Gas from being displayed as a switch option during dives.  If Gas 2 is set Off, Gas 3 is automatically set 

Off.  An OFF setting does not affect the FO2 or PO2 Alarm values set.

•  A (hold) to scroll upward through FO2 set points at a rate of 8 per second from OFF to Air to 21 through 100 (%) in 

increments of 1%.

 > The scroll will stop when A is released, or at 32, then 50, then 80%, (even if A is held depressed).  Press/hold A again will 

resume the scroll through 100, then stop at OFF or Air (or 21%).

•  A (< 2 sec) to step upward through FO2 set points one at a time.

Fig. 16 - Set FO2 (Air)

Fig. 17 - Set FO2 (Nitrox)

Fig. 15 - Set F LEAD-IN

Содержание PRO PLUS 3

Страница 1: ...1 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 PRO PLUS 3 DIVE COMPUTER OPERATING MANUAL...

Страница 2: ...GLO 17 Set Sampling Rate SR 17 SET TIME 17 Set Date Format 18 Set Hour Format 18 Set Time 18 Set Date 18 SET OPERATING MODE 18 HISTORY MODE 19 SERIAL NUMBER 19 DIVE MODE FEATURES 20 BAR GRAPHS 21 TLB...

Страница 3: ...All rights are reserved PATENT NOTICE U S Patents have been issued or applied for to protect the following design features Data Sensing and Processing Device U S Patent No 4 882 678 Air Time Remainin...

Страница 4: ...4 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 Welcome to OCEANIC and THANK YOU for choosing the PRO PLUS 3...

Страница 5: ...5 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 FEATURES and FUNCTIONS...

Страница 6: ...rough menu selections A hold to scroll forward through menu selections S 2 sec to access or save selections A 2 sec while viewing the last selection in the menu will revert to the first selection such...

Страница 7: ...M is exceeded in NORM mode or 400 FT 120 M in GAUG mode A single short beep which cannot be disabled sounds when After 10 minutes on the surface after the Violation dive 3 short beeps which cannot be...

Страница 8: ...t dive LOW BATTERY WHILE ON THE SURFACE 2 75 volts warning level DC functions continue Backlight is disabled Battery icon appears solid Fig 1a 2 50 volts Too Low alarm level All operations cease Batte...

Страница 9: ...9 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 NORM SURFACE MODES...

Страница 10: ...if FO2 for any gas is set for Nitrox Gas tank 1 icon default on surface Dive number with icon up to 24 for that operating period 0 if no dive made yet Graphic NOR operating mode Tank 1 Pressure with P...

Страница 11: ...Dive times are reduced to the values of the next higher 3000 foot 915 meter Altitude Refer to tables in back Plan Lead in information includes Fig 8A B Max Depth allowed for the PO2 alarm value set f...

Страница 12: ...to access Data 1 for the dive Preview displayed S 2 sec to revert to the Lead in screen S press to activate SMARTGLO Backlight Log Data 1 information includes Fig 12 Log book icon Pre dive SI hr min...

Страница 13: ...ation includes Fig 16 17 Max Depth allowed for the PO2 alarm set with MAX and FT or M icons blank if Air NX Z or DSAT CF icons those that apply Gas 1 icon PO2 alarm value set ATA for Gas 1 with icon b...

Страница 14: ...e selected saved S 2 sec to step back to Set Audible Alarm Set EDT Alarm information includes Fig 22 Graphic OFF or ON flashing Time with EDT and min icons last value saved A 2 sec to step through sel...

Страница 15: ...Turn Pressure Alarm information includes Fig 25 Graphic turn Graphic OFF or ON flashing Tank Pressure with PSI or BAR icon last value saved A 2 sec to step through selections OFF ON and Set one at a...

Страница 16: ...Fig 30 Graphics dEEP STOP with Stop arrow bar and DS icons Graphic OFF or ON flashing A 2 sec to toggle between OFF and ON S 2 sec to save the setting and access Set SS S 2 sec to step back to Set Un...

Страница 17: ...the selections OFF ON Set S 2 sec to save the setting S 2 sec to step back to Set CF If OFF or ON is selected operation will access Set SR If Set is selected Duration Time seconds will flash in place...

Страница 18: ...d through Minute set points one at a time S 2 sec to save the Time set point and access Set Date S 2 sec to revert to Set Hour Format Set Date information includes Fig 40 The sequence for setting date...

Страница 19: ...cludes Fig 44 HIST icon with graphic EVER Max Depth ever recorded with MAX and FT or M icons Longest Elapsed Dive Time ever recorded during a single dive up to 599 min with EDT and min icons S 2 sec t...

Страница 20: ...20 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 DIVE MODE FEATURES...

Страница 21: ...Deco dives considered more risky Z Pelagic Z performance is based on Buhlmann ZHL 16c It features NDLs that are considerably more conservative especially at shallower depths To create even greater mar...

Страница 22: ...displayed as DTR Fig 48a It will also be displayed graphically as the TLBG Fig 48b As you ascend the TLBG segments will recede as control shifts to slower compartments This is a feature of the decompr...

Страница 23: ...23 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 NORM DIVE MODES...

Страница 24: ...cklight NO DECO ALT 2 information includes Fig 54 Time of Day hr min with AM or PM icon if 12 Hour Format no icon if 24 Hour Format Temperature with F or C A 2 sec to access ALT 2 if Nitrox Revert to...

Страница 25: ...r BAR icon graphic SPG Submersible Pressure Gauge if Gas 2 or 3 is in use TLBG A 2 sec to access ALT 1 A 2 sec to access Gas Switch routine unless Gas 2 is set Off S 2 sec to acknowledge alarms S pres...

Страница 26: ...tion includes Fig 64 Max Depth with MAX and FT or M icons NX DSAT or Z Gas 1 2 3 CF icons those that apply Air Time Remaining with ATR icon 2 dashes if Gas 2 or 3 is in use Total Ascent Time with TAT...

Страница 27: ...l continue to be displayed as dashes for the remainder of that dive The Log for that dive will also display dashes for Max Depth VGM VIOLATION GAUGE MODE Operation will enter VGM when Deco requires a...

Страница 28: ...p the PO2 value 1 60 with icon will alternate with Deco Stop Depth Time once each minute No indication will be given suggesting ascent which is the diver s option pending conditions of the dive PO2 on...

Страница 29: ...29 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 DIGITAL GAUGE MODE...

Страница 30: ...e described previously for NORM Mode Button operations are also similar to those in NORM A 2 sec step forward through Menu items A hold scroll forward through Menu items S press activate the SMARTGLO...

Страница 31: ...31 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 REFERENCE...

Страница 32: ...r better microprocessor Microsoft Windows XP Vista or 7 Super VGA card or compatible video graphics adaptor 256 color or greater with a minimum 800 X 600 pixel screen area of display settings 16MB of...

Страница 33: ...ating entrance of moisture into the unit If corrosion is found return the Pro Plus 3 to an Authorized Oceanic Dealer and DO NOT attempt to use it until it has re ceived factory service Moisture in the...

Страница 34: ...me that the Wet Contacts are bridged When diving in high altitude waters from 3 001 to 14 000 feet 916 to 4 270 meters the Pro Plus 3 automatically adjusts to these conditions providing corrected Dept...

Страница 35: ...3 12 11 11 10 9 9 9 8 30 16 12 11 10 9 9 9 8 8 7 7 7 33 13 9 9 8 8 7 7 7 7 6 6 6 36 10 8 7 7 7 6 6 6 5 5 5 5 39 9 7 6 6 6 6 5 5 5 5 5 4 42 8 6 6 5 5 5 5 5 4 4 4 4 45 6 5 5 5 5 4 4 4 4 4 4 4 48 6 5 5 4...

Страница 36: ...evel beginning at 3 001 feet 916 meters elevation and every 1 000 feet 305 meters higher Power 1 3 volt type CR2 Lithium battery Shelf life Up to 5 years dependent on battery manufacturer Replacement...

Страница 37: ...itrox Value 21 to 100 1 PO2 Value 0 00 to 1 99 ATA 01 ATA 1 when 2 00 O2 Saturation 0 to 100 1 Pressure 0 to 5000 PSI 345 BAR 5 PSI 1 BAR Elapsed Dive Time 0 to 599 min 1 minute Dive Time Remaining 0...

Страница 38: ...orized Oceanic Dealer Date Service Performed Dealer Technician OCEANIC WORLD WIDE OCEANIC USA 2002 Davis Street San Leandro CA 94577 Tel 510 562 0500 Fax 510 569 5404 Web www OceanicWorldwide com E ma...

Страница 39: ...39 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 NOTES...

Страница 40: ...40 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 PRO PLUS 3 DIVE COMPUTER OPERATING MANUAL...

Отзывы: