BAR GRAPHS

Tissue Loading Bar Graph (TLBG)

The Tissue Loading Bar Graph (Fig. 1a) represents tissue loading
of nitrogen, showing your relative no decompression or decom-
pression status.  As your depth and elapsed dive time increase,
segments will add to the Graph, and as you ascend to shallower
depths, the Bar Graph will begin to recede, indicating that
additional no decompression time is allowed for multilevel
diving.

The Tissue Loading Bar Graph monitors 12 different nitrogen
compartments simultaneously and displays the one that is in
control of your dive.  It is divided into a No Decompression
(normal) zone, a Caution zone (also No Decompression), and a
Decompression (danger) zone.

While you cannot provide a guarantee against the occurrence of
decompression sickness, you may choose your own personal
zone of caution based upon age, physique, excessive weight,
etc., to reduce the statistical risk.

NOTE:  Displays associated with oxygen and the O2
Bar Graph will only appear if FO2 has been set at a
value other than 'Air' (e.g., a numerical value).

Fig. 1 - TLBG

a

Содержание Personal Dive Computer Veo 100Nx

Страница 1: ...OCEANIC VEO 100Nx Operating Manual r04 cover art provided separately...

Страница 2: ...ing design features Dive Time Remaining U S Patent no 4 586 136 Data Sensing and Processing Device U S Patent no 4 882 678 and Variable Ascent Rate Indicator U S Patent no 5 156 055 User Setable Displ...

Страница 3: ...gen Bar Graph O2BG 10 Variable Ascent Rate Indicator VARI 10 ALPHA NUMERIC DISPLAYS 11 Depth Displays 11 Time Displays 12 Temperature Display 12 POWER SUPPLY 13 Battery Indicator 13 Low Battery Condit...

Страница 4: ...LAN AND DIVE MODES 29 PRE DIVE PLANNING SEQUENCETM 30 TLBG TISSUE LOADING BAR GRAPH 32 O2BG OXYGEN ACCUMULATION BAR GRAPH 32 VARI VARIABLE ASCENT RATE INDICATOR 32 CONTROL OF DISPLAYS 33 NO DECOMPRESS...

Страница 5: ...uence 48 Log Mode 49 AFTER THE FIRST 2 HOURS 51 WET CONTACTS 52 RESET CLEAR FEATURE 53 GENERAL 55 CARE AND CLEANING 56 INSPECTIONS AND SERVICE 56 MODULE REMOVAL FROM BOOT 58 BATTERY REPLACEMENT 58 RET...

Страница 6: ...r Icon Ascend Arrow c Graphic Maximum PO2 d Tissue Loading Bar Graph e Graphic Maximum Depth f Icon Log Mode g Icon Dive No h Icon Temperature i Graphic Depth j Variable Ascent Rate Indicator k Graphi...

Страница 7: ...or to diving with the Veo 100Nx you must also read and understand the Oceanic Dive Computer Safety and Reference Manual Doc No 12 2262 which provides Important Warnings and Safety Recommendations as w...

Страница 8: ...c No 12 2262 provided with your Veo 100Nx It contains information that you must become familiar with prior to diving with your Veo 100Nx Remember that technology is no substitute for common sense and...

Страница 9: ...sue Loading Bar Graph monitors 12 different nitrogen compartments simultaneously and displays the one that is in control of your dive It is divided into a No Decompression normal zone a Caution zone a...

Страница 10: ...visual representation of ascent speed i e an ascent speedometer The segments of the Variable Ascent Rate Indicator represent two sets of speeds which change at a reference Depth of 60 FT 18 M Refer t...

Страница 11: ...Displays During a dive the Current Depth display Fig 3a indicates depths from 0 to 330 FT 99 9 M in 1 FT 0 1 M increments By accessing alternate Main Dive Displays the Maximum Depth reached during tha...

Страница 12: ...ay Fig 5a and a second time display Fig 5b is located in the center right Both displays are identified by a clock icon Time of Day can be set for 12 hour format Am Pm or 24 hour format Temperature Dis...

Страница 13: ...on of battery condition When power is sufficient for normal unit operation the Indicator will be displayed during Surface Mode Fig 7a The Indicator will not be displayed during Dive Mode s Low Battery...

Страница 14: ...on is not pressed to activate the unit prior to a dive and a Low Battery Condition exists the Battery Indicator will appear flashing as a warning upon descent to 5 FT 1 5 M No other information will b...

Страница 15: ...the O2 Bar Graph will not appear on the display for that dive or subsequent dives unless FO2 is set for a numerical value 21 to 50 Once a dive is made with the unit set as a nitrox computer FO2 set f...

Страница 16: ...t can be achieved with a PO2 of 1 60 ATA will also be displayed FO2 must therefore be reset for each repetitive nitrox dive or the value will automatically Default to 50 and the dives will be calculat...

Страница 17: ...or to diving with the Veo 100Nx you must also read and understand the Oceanic Dive Computer Safety and Reference Manual Doc No 12 2262 which provides Important Warnings and Safety Recommendations as w...

Страница 18: ...tage to ensure that everything is within tolerance and functioning properly When the button is held depressed and the Diagnostic countdown reaches 00 a Serial Number screen appears displaying the unit...

Страница 19: ...vate and display the H2O graphic SURFACE SEQUENCE While on the surface the unit will automatically scroll through a Sequence of displays including Surface Mode Fly Mode DeSat Mode Plan Mode As the Sur...

Страница 20: ...can be made in sequence one after the other or you can access a specific item that you want to set bypassing others Set Mode Access Timing To access Set Mode while the Surface Sequence is scrolling p...

Страница 21: ...ashing Fig 18 Press release the button repeatedly to increase the FO2 value from 21 to 50 in increments of 1 then display AIR again For each FO2 value that appears the display indicates the Maximum De...

Страница 22: ...pted the FO2 setting the Set Wet Activation screen appears with the Set Point flashing Fig 20 or While the Surface Sequence is scrolling depress the button for 4 seconds to bypass Set FO2 Release the...

Страница 23: ...urface Sequence is scrolling depress the button for 6 seconds to bypass Set FO2 and Set Wet Activation Release the button when the Set Units screen appears with the Set Point flashing Press release th...

Страница 24: ...oint flashing Fig 22 or While the Surface Sequence is scrolling depress the button for 8 seconds to bypass Set FO2 Wet Activation and Units Release the button when the Set Hour Format screen appears w...

Страница 25: ...he button when the Set Time screen appears with the Hour Set Point flashing Press release the button repeatedly less than 2 seconds each time to advance the Hour Set Point in increments of 1 Hour per...

Страница 26: ...nce is scrolling press the button for 14 seconds to bypass Set FO2 Wet Activation Units Hour Format and Time Release the button when the Set PO2 Alarm screen appears with the PO2 Set Point flashing Pr...

Страница 27: ...ult screen appears with the Set Point flashing Fig 25 or While the Surface Sequence is scrolling depress the button for 16 seconds Release the button when the Set FO2 50 screen appears with the Set Po...

Страница 28: ...DE DESAT MODE PLAN MODE SURFACE SEQUENCE LOG MODE SURFACE SEQUENCE SET MODE SET MODE SEQUENCE FO2 WET ACTIVATION UNITS HOUR FORMAT TIME PO2 ALARM FO2 50 DEFAULT NOTE The Veo 100Nx will enter Dive Mode...

Страница 29: ...or to diving with the Veo 100Nx you must also read and understand the Oceanic Dive Computer Safety and Reference Manual Doc No 12 2262 which provides Important Warnings and Safety Recommendations as w...

Страница 30: ...oxygen exposure limits For repetitive dives the PDPS indicates adjusted dive times that are available for the next dive based on residual nitrogen or oxygen accumulation whichever is in control follo...

Страница 31: ...be displayed If the Tissue Loading Bar Graph is displayed Fig 26 that next dive is calculated to be controlled by nitrogen loading If the O2BG and O2 symbol are displayed Fig 27 it is calculated to b...

Страница 32: ...ox the Oxygen Accumulation Bar Graph O2BG will add segments to represent oxygen accumulation for that dive or 24 hour period whichever amount is greater VARI VARIABLE ASCENT RATE INDICATOR Fig 28c The...

Страница 33: ...hich cautionary type information is dis played e g Decompression High PO2 High O2 etc there is a Main Display of important information relevant to the specific condition Other screens of information c...

Страница 34: ...on 1 time 2 seconds to change the screen to Main Display 3 Press release the button 2 times 2 seconds each time to change to Main Display 4 if a Nitrox dive or 1 Press release the button 3 times 2 sec...

Страница 35: ...ompression dive in which Depth exceeded 30 FT 9 M a Safety Stop screen will appear displaying a Stop at 15 FT 4 5 M with a 3 minute Countdown Timer that counts down from 3 00 to 00 min sec The Safety...

Страница 36: ...M of and below the re quired Stop Depth both Arrows and the Bar appear solid Total Ascent Time Total Ascent Time Fig 36a includes Stop Times required at all required decompression ceilings and vertic...

Страница 37: ...te Displays can be accessed that will automatically revert to the Main Default Display after 5 seconds Deco Dive Main Default Display Fig 37 Information includes Current Depth required Ceiling Stop De...

Страница 38: ...Alternate Display 2 Fig 39 Information includes Current Depth Temperature Time of Day and icon Total Ascent Time both Arrows and the Deco Bar and the applicable bar graphs Press release the button 1...

Страница 39: ...Depth Current Depth and applicable bar graphs will be displayed If you descend below the required decompression ceiling before 5 minutes have elapsed the Veo 100Nx will continue to func tion in Decom...

Страница 40: ...8 M and offers no indication of how much time spent underwater would result in the need for a greater Stop Depth If your Decompression obligation requires a Ceiling Stop Depth between 60 FT 18 M and 7...

Страница 41: ...f a ceiling much greater than 60 FT 18 M is required an Immediate Violation Mode will be entered This situation would be preceded by entering Delayed Violation Mode 2 The Veo 100Nx would then operate...

Страница 42: ...2 PDPS or Time to Fly and Desaturate features The countdown timer that appears when you try to access Time to Fly does not represent Time to Fly It is only provided to inform you of the time remaining...

Страница 43: ...displayed Fig 47 If PO2 continues to increase the value displayed will increase toward a maximum display value of 5 50 ATA in increments of 01 ATA When it reaches a value of 1 60 ATA or the PO2 Alarm...

Страница 44: ...nce to place a wider margin of protection between you and the Limits If the theoretical amount of oxygen accumulated equals or exceeds the limit for a single exposure or the exposure limit for a 24 ho...

Страница 45: ...to diving with the Veo 100Nx you must also read and understand the Oceanic Dive Computer Safety and Reference Manual Doc No 12 2262 which provides Important Warnings and Safety Recommendations as wel...

Страница 46: ...perature ambient Time of Day and icon Battery icon Surface Interval time colon flashing and icon flashing Tissue Loading Bar Graph O2 Bar Graph if set for Nitrox During the Transition Period Log Mode...

Страница 47: ...idered a new dive For the remainder of the first 2 hours after surfacing information will continue to be displayed as the Surface Sequence scrolling through the Surface Mode Fly Sat Plan screens You w...

Страница 48: ...profile s did not enter decompression If your diving involved decompression or a repetitive multi day profile it is strongly recommended that you wait a full 24 hours after your last dive to add a gre...

Страница 49: ...1 therefore there may be multiple 1 dives in the Log Each dive has 3 Log screens Dive Identifier Preview Dive Data and O2 Data if a Nitrox dive Dives are displayed in a reverse sequence that starts wi...

Страница 50: ...LBG showing tissue nitrogen loading at the time you surfaced at the end of the dive The segment that reflects the maximum loading during the dive will appear flashing Press release the Button to view...

Страница 51: ...l no longer be displayed The Time to Fly and Desat countdown screens Fig 58 will be displayed alternately for 3 seconds each until they count down to 0 00 or another dive is made To access other modes...

Страница 52: ...ry the graphic H2O will disappear from the display If the unit is not cleaned and dried prior to the countdowns reaching 0 00 hr min or making another dive it will shut off then automatically reactiva...

Страница 53: ...cent dive is being displayed to access the Reset screen The graphics CLR and id will appear with the Key Code 01 01 the first 2 digits flashing Fig 62 Release the button If necessary to change the fir...

Страница 54: ...important reason for not push ing the No Decompression and Oxygen Accumulation Limits and a critical reason to avoid entering Decompression If you dive in situations where your trip would be ruined o...

Страница 55: ...diving with the Veo 100Nx you must also read and understand the Oceanic Dive Computer Safety and Reference Manual Doc No 12 2262 which provides Important Warnings and Safety Recommendations as well as...

Страница 56: ...vinegar 50 fresh water bath After removal from the bath place the unit under gently running water and towel dry before storing Transport your unit cool dry and protected INSPECTIONS AND SERVICE Your V...

Страница 57: ...your original sales receipt and Warranty Registra tion Card Send freight prepaid and insured using a traceable method to the nearest Oceanic Regional Service Facility or to Oce anic USA If shipping t...

Страница 58: ...st Boot it will be necessary to peel the lips of the Boot downward off the Module while applying pressure from underneath working it out slowly BATTERY REPLACEMENT The Battery Compartment should only...

Страница 59: ...ow the Ring to drop out into your hand Remove the Battery Hatch Battery Removal Remove the Retaining Bar located across the lower portion of the Battery Fig 65a Remove the Hatch O ring DO NOT use tool...

Страница 60: ...llation Slide a new 3 volt type CR2450 Lithium Battery negative side down into the Battery Cavity Slide it in from the right side and ensure that it slides under the contact clip on the left rim of th...

Страница 61: ...Ring down off your thumb and into position around the Battery Compartment The tabs on the Retaining Ring fit down into the two slots located at the 2 and 8 o clock positions Using your fingers turn t...

Страница 62: ...eanic Dealer for a complete evaluation before attempting to use it RETURNING THE MODULE TO BOOT If the Boot was fitted with a Spacer and it was previously removed replace the Spacer into the Boot Orie...

Страница 63: ...tes while it is activated or every 30 minutes when it is not activated At an Altitude of 3 001 feet 916 meters it will automatically recalibrate itself to measure depth in feet of fresh water rather t...

Страница 64: ...ased on NOAA tables OPERATIONAL MODES Activation Diagnostic Serial Number Surface Time to Fly Countdown Desaturation Countdown Pre Dive Planning Sequence 30 to 190 FT 9 to 57 M Dive Log Preview Dive D...

Страница 65: ...ution Dive Number 0 12 1 Depth 0 330 FT 0 99 9 M 1 FT 0 1 M Maximum Depth 0 330 FT 0 99 9 M 1 FT 0 1 M FO2 Set Point Air 21 50 1 PO2 Value 0 00 5 50 ATA 01 ATA Dive Time Remaining 0 00 9 59 hr min 1 m...

Страница 66: ...o Deco Caution zone 1 Caution zone 1 Decompression Warning zone 1 Danger zone 1 Variable Ascent Rate Indicator 60 FT 18 M Shallower Deeper than 60 FT 18 M segments FPM MPM segments FPM MPM 0 0 10 0 3...

Страница 67: ...ters and 14 000 feet 4 270 meters at intervals of 1 000 feet 305 meters Power Battery 1 3 vdc type CR2450 Lithium battery Shelf life Up to 5 years Replacement User replaceable annual recommended Life...

Страница 68: ...es after the dive if the FO2 Default is ON If the FO2 Default is OFF the value will remain at the value set for that activation period Operating Temperature The Veo 100Nx will operate in waters having...

Страница 69: ...69 NOTES...

Страница 70: ...United Kingdom Tel 44 1404 891819 Fax 44 0 1404 891909 Web www OceanicUK com E mail helpyou oceanicuk com OCEANIC FRANCE Nice France Tel 33 0 4 93 72 43 00 Fax 33 0 4 93 72 43 05 E mail info subaquad...

Страница 71: ...o Rev No __________________ Date of Purchase _____________________ Purchased From _____________________ Below to be filled in by an Authorized Oceanic Dealer R E S P O NSIBLE D I V E R Date Service Pe...

Страница 72: ...VEO 100Nx Operating Manual Doc No 12 2725 r04 6 2 09 cover art provided separately...

Отзывы: