Sauna & Steam
Oceanic Saunas 01902 450 550 sales
@oceanic-saunas.co.uk www.oceanic-saunas.co.uk
8
Sauna Heater Manual
5.5. Controller Parts Description
No.
Description
Function instruction
1
On/off button
Push to operate
2
Light button
Push to operate for sauna room light
3
Fan button
Push to operate for control box fan
4
Setting button
Preset time and temperature and the setting confirmation
5
Increase button
Press to increase
6
Increase button
Press to decrease
7
Mode button
Change working mode
8
Time display
Display working time or waiting time to work
9
Temp. display
Display temperature
10
Light LED
Indictor Led for sauna room lamp
11
Model LED
Indictor LED for working mode, on mean under A model ,sauna heater is
working
12
Wait LED
Indicator LE D for working mode, on mean under B waiting to work
13
Sauna room
Door(interlock)
indicator LED
indicator LED is on: the sauna heater stop working ,there is control signal
to control box main circuit board when the door is open , the default is the
connection switch is downward (opposite side of ON), when the door is open ,
there is on signal to circuit board , the LED is on and sauna heater stop work.
Such as on sauna room door install a switch connect to circuit board , the switch
‘s on or off signal can control sauna heater work or stop. when you need the
switch send off signal to working , the default is ok, when you need the sauna
heater under the on signal to work , just push the switch circuit board to “on”
side”
14
High temperature LED
indicator LED is on , sauna heater stop work . the sauna room temperature
higher then 120 centigrade . high temperature cut off switch works, when the
temperature in sauna room down to 100 centigrade , and find out the high
temperature problem then preset the switch by hand
15
Fan LED
Fan is on - not used in any Oceanic Saunas
16
Heating LED
On means the heat element is working
17
Stop working LED
indicator LED for stop working , the sauna room temperature exceed the preset
temperature , the heat element pause(when temperature 2 centigrade lower
than preset temperature ,sauna heater will work again,
Keypad Buttons and LEDS