background image

Sauna & Steam

Oceanic Saunas  01902 450 550  [email protected]

3

Steam Generator Manual

1.  Introduction

Thank you for choosing to buy our Oceanic steam generator, please take the time to read these 

instructions before you begin as they contain important information about the installation and 

maintenance requirements.

“Oceanic” steam generators are available in specifications from 3kw to 12kw and are equipped 

with our OC-A intelligent controller. With this not only can you control the temperature and time 

duration of your steam bath but also the light of the steam room, the automatic drain valve, 

key-lock, alter the temperature display between Centigrade and Fahrenheit; as well as displaying 

the steam generator‘s status by the 8 LED’s on the panel, heating, water inlet, temperature, drain 

status etc. note also that one “OC-A” controller can control multiple “Oceanic” steam generators.

Every “Oceanic” steam generator is thoroughly tested before leaving the factory so there may be 

the remains of water inside the boiler.

2.  Important Notes

•  Read the manual before installation and operation.

•  This Equipment must be installed by competent person. 

•  This equipment must be connected to an all pole isolator

•  Disconnect the power supply before exposing electrical connections.

•  Confirm the right voltage to your steam generator 1 or 3 phase.

•  For hard water areas please read our descaling section on page???

•  Water supply must have maximum of 1 bar pressure, recommend the use of a pressure 

reducing valve if necessary

3.  Safety Precautions 

•  Elderly persons, pregnant women, or these suffering heart disease, high blood pressure, 

diabetes or not in good health are advised to seek medical opinion before using a steam room.

•  Do not smoke in the steam room.

•  Avoid using the steam room immediately after strenuous exercise. 

•  Do not use the steam room when under the influence of alcohol.

•  Leave the steam room at once if you feel sleepy, sick or uncomfortable.

•  Ensure there is good ventilation for the steam room.

•  We do not recommend that children under 16 use this product.

•  Commercial operators should post a notice of these precautions in a prominent position.

Steam entering the steam room will be scalding hot; take care to position the inlet nozzle 

away from where users will sit and/or provide adequate guarding, post a notice to caution 

users.

4.  Electrical connection

 

A qualified electrician will have no problem installing this system with the provided wiring 

schematic and with the help of the circuit diagram mounted inside the respective control unit. 

According to the valid regulations, the electrical connection of the steam generator and the 

control box has to be carried out by an authorised electrician. In case of a warranty claim, you are 

kindly requested to present a copy of the invoice from the electrician.

Содержание OC-105 S

Страница 1: ...Oceanic Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Sauna Steam STEAM GENERATOR Domestic Light Commercial Assembly and operating m...

Страница 2: ...e 2 OC A Controller Parameters 8 5 7 Temperature Sensor Parameters 8 6 OC A Controller Description 9 7 Installation 10 7 1 Generator Size 10 7 2 Steam Generator Location 11 7 3 Water and Steam Connect...

Страница 3: ...your steam generator 1 or 3 phase For hard water areas please read our descaling section on page Water supply must have maximum of 1 bar pressure recommend the use of a pressure reducing valve if nec...

Страница 4: ...omestic OC 40 4 17A 390 190 335 1 2 1 2 1 2 White OC 60 6 26A 8 6A 390 190 335 1 2 1 2 1 2 White OC 80 8 35A 11 6A 450 190 353 3 4 1 2 1 2 Chrome Steam On Demand OC 60 S 6 26 8 6 390 190 335 15 1 2 1...

Страница 5: ...rol two or more steam generators e g if you need a 24KW steam generator you can use one OC A controller to control two 12kw steam generator or three 10kw steam generators Temperature sensor OC A contr...

Страница 6: ...45 72 60 OC 80 90 450 195 353 35 135 45 72 60 OC 10 120 390 206 353 25 135 45 77 60 5 2 Steam Generator Frame Sizes 5 3 Clearance distances 5 4 Ventilation Ensure air flow into area where steam gener...

Страница 7: ...Boiler 6 Insulation material Reduce the loss of the boiler heat 7 Water lever probe Detect the water level 8 Steam outlet Steam outlet 9 Pressure relief valve Operates if the pressure in the boiler ex...

Страница 8: ...x 22 When the time window displays Long the generator will operate continuously until it is switched off MODEL Detected Scope Max Cut out Temperature Size mm o C o F o C o F L W H OC S 0 110 32 230 60...

Страница 9: ...is filling green water level OK Note if the LED remains red in excess of 5 minutes check water supply 12 L3 Indicator LED for drain red for draining green for draining and filling at the same time 13...

Страница 10: ...r and cause a blockage I e the pipe must not go down and then up There must be no valve or other blockage in the steam pipe The steam pipe should be metal of other material that can endure 150 C tempe...

Страница 11: ...holes in the back plate Then with the front cover removed fix the 3rd screw to secure the unit in place 10m The steam generator can be installed anywhere that is dry and has an airflow Example locati...

Страница 12: ...er supply using a flexible hose with 1 2 inch fittings iii Steam outlet 1 2 inch or 3 4 inch use the same dimension copper pipe to connect it if the steam pipe is longer than 5 meter it should be insu...

Страница 13: ...rom the steam outlet Use a 4mm screw fix it in place and then connect to the wire from the controller vi Fix protective cover supplied over the temperature Temperature Sensor 4mm Screw Cover to protec...

Страница 14: ...operators may wish to take advantage of the steam on demand function which will allow customers to press the steam on demand button located outside the steam room after which the generator will opera...

Страница 15: ...Sauna Steam Oceanic Saunas 01902 450 550 sales oceanic saunas co uk 15 Steam Generator Manual...

Страница 16: ...es the factory the default settings are 40o and 1 hour of operation these can be adjusted as follows i Time setting press set key the time display window will flash press to adjust the time every pres...

Страница 17: ...main circuit board the transformer has failed or has a loose connection Control panel lit up but no steam Water probe Control lead connection Water supply 1 If L2 is green L7 is yellow remove the wat...

Страница 18: ...d mixed with water Citric acid can be purchased from www thebathingplace com www oceanic saunas eu 12 1 Descaling procedure i Firstly push the drain button to empty the tank check the valve is drainin...

Страница 19: ...trical elements and failures resulting from misuse or abuse such as a failure to descale as explained previously If you are using the generator for more than 20 hours a week in a hard water area witho...

Отзывы: