Sauna & Steam
Oceanic Saunas 01902 450 550 [email protected] www.oceanic-saunas.co.uk
7
Apollo Steam OSX
Chart 2d. OC-APS75 Sauna Heater with Steam unit
Mode
Heater
Power (kW)
Mini Steam
Power (kW)
Total
Power (kW)
Max Temp
(oC)
Steamer
Operation (%)
Sauna
7.5
0
7,5
100
0
Caldarium
5.5
2
7.5
65
80
Sanarium
5.5
2
7.5
56
90
Tepidarium
5.5
2
7.5
48
100
Chart 2e. OC-APS90 Sauna Heater with Steam unit
Mode
Heater
Power (kW)
Mini Steam
Power (kW)
Total
Power (kW)
Max Temp
(oC)
Steamer
Operation (%)
Sauna
9
0
9
100
0
Caldarium
6
2
8
65
80
Sanarium
6
2
8
56
90
Tepidarium
6
2
8
48
100
6. General Setup Overview
According to the valid regulations, the electrical connection of the steam generator and the
control box has to be carried out by an authorised electrician. In case of a warranty claim, you are
kindly requested to present a copy of the invoice from the electrician.
Important Notice:
Please pay close attention to the drawing below. The mains power is soley
supplied to the OC-ST control and is diverted from here to the heater and steam generator . You
must not wire directly from the mains to either the sauna heater or mini steam generator.
6.1. Wiring Schematic
Control box
OC - ST
Mains in 230v 1N
or 400v 3N
3 Core silicone 0.75 or 1mm (Not supplied)
Lighting circuit - 240v
Switched from button on Keypad
Temperature Sensor
4 core 12v cable
(4m Supplied)
3 core 2.5mm Silione cable (Not Supplied)
Inside Sauna
Any power cable that enters
the sauna must be rated to
150
o
C (BSEN 6141)
The 12v signal cable should
not enter the sauna higher
than 500mm from the floor.
The control box and
keypad must be installed
outside the sauna cabin.
Key
Blue - 12 volts
Black - 240 volts
Steam
Unit
Sauna Heater
5v Control Cable
(5m Supplied)
3 Core 5v Signal Cable (4m Supplied)
5 core silicone cable
(Not Supplied)
Fig2. Wiring Schematic