4
Multiples of the 5980 Whistle Operating Module can be installed on an NMEA2000® network.
Each unit will require a unique Device Instance Address, which is set using the small rotary
switch on the front face of the unit.
Valid Device Instances are “0” through to “F”. The switches are simply turned to the desired
Device Instance with a small screwdriver.
The 5980 Whistle Operating Module has two horn circuits and two warning lamp circuits, each
equipped with a 1 Amp relay that can drive the units directly. If a greater current is required
they can drive a larger external relay to supply that extra current.
A small green LED next to each output lights to indicate that the circuit is energised.
•
Do not use chemical cleaners as they may remove paint or markings or may
corrode the enclosure or seals.
•
Ensure that the unit is mounted securely and cannot be moved relative to
the mounting surface. If the unit is loose, tighten the mounting screws.
•
Check the security of the cables connected to the NMEA2000® connector,
tighten if necessary.
•
Check the security of the cables connected to the WAGO terminal block,
reseating them if necessary.
As Oceanic Systems are constantly improving their products, specifications are subject to
change without notice. Oceanic Systems’ products are designed to be accurate and reliable.
However, they should only be used as aids to navigation and not as a replacement for traditional
navigation aids and techniques.
Parameter
Comment
4 Independent Relay Outputs
Fully Isolated, SP NO contacts
DC Power Rating
1 Amp at 35 Volts DC resisitive load
Wire Sizes
0.08 – 2.5mm² section
Relay Outputs
CONFIGURATION
3
OPERATION
4
MAINTENANCE
5
TECHNICAL SPECIFICATION
6