OCEANAIRE OPACH4212 Скачать руководство пользователя страница 3

 Model Number:

MODEL:  OPACH4212

GENERAL INFORMATION

The Oceanaire OPACH4212 is an outdoor portable heat pump designed for temporary 
cooling and heating applications.   With 3.5 tons of cooling capacity the OPACH4212
can deliver cooling for almost any industrial application.  With 38,000 BTUH of Heating capacity,
and 7 KW Auxiliary Electric Heat, the OPACH4212 can heat a defined space as well.

The unit is designed for industrial applications.  The heavy-gauge 2” x 2” powder coated steel 
frame safeguards the unit from its surroundings, and aids with handling and storage.  8-inch 
swivel casters allow for improved mobility and maneuvering on job sites.  Two of the swivel 
casters are equipped with rotational pin-locks, while the other two swivel casters are equipped 
with brakes for the securing the unit on-site as well as for storage and transit.
  
The Power Connection, Main Breaker and duct connections are all located on the left side of the 
unit for quicker installation and set-up.  All electrical receptacles are equipped with weather proof 
covers.  The 12-inch supply and return air collars are located on the same side to accomodate 
access to the controlled space.  The Drain tube is located on the lower right side of the 
unit.  The Drain Tube with P-trap is outfitted with a 3/4” MGHT connector for hose connection 
purposes.  The unit is equipped with a storage compartment for the thermostat/cable assembly.

  

HANDLE

75.5” LENGTH WITH HANDLE

49-1/2” 

8-INCH 

SWIVEL CASTER

WITH ROTATIONAL 

PIN LOCK

OPACH4212 LEFT SIDE 

8-INCH 

SWIVEL CASTER

WITH BRAKE

2” X 2” WELDED

IRON FRAME

42” 

OPACH4212 FRONT 

GENERAL DESCRIPTION 

FORKLIFT POCKETS

HVDR

HVDR

OA-EISM-OPACH4212- REV. 04062023

Page 3

Содержание OPACH4212

Страница 1: ...OOR PORTABLE HEAT PUMP WITH FRAME ENGINEERING INSTALLATION AND SERVICE MANUAL OCEANAIRE Inc 1731 Wall Street Suite 100 Mount Prospect IL 60056 847 583 0311 oceanaire inc com OA EISM OPACH4212 REV 0406...

Страница 2: ...nit As with all commercial air conditioning equipment it is recommended to have the OPACH4212 sized and installed by a licensed specifying engineer and contractor in accordance with all local and stat...

Страница 3: ...vel casters are equipped with brakes for the securing the unit on site as well as for storage and transit The Power Connection Main Breaker and duct connections are all located on the left side of the...

Страница 4: ...TRICAL Locking 250V Power Connection Receptacle 50 Amp Circuit Breaker for Unit Power Protection 40 Amp Auxiliary Heat Breaker 24 VAC Thermostat with 50 ft detachable cable Automatic Defrost Modes in...

Страница 5: ...NEL TOP OR SIDE MAIN BREAKER BOX OPACH4212 LEFT SIDE OPACH4212 DETAILS THERMOSTAT STORAGE COMPARTMENT OPACH4212 REAR CONTROLS ACCESS PANEL EVAP BLOWER ACCESS PANEL THERMOSTAT CABLE RECEPTACLE NOTE THE...

Страница 6: ...tion 5 Connect Power Cord to unit using the locking 250 VAC Receptacle POWER INLET Hubbell CS8275 POWER CONNECTOR Hubbell CS8264C or Equivalent 6 Check that all power connections are secure and that t...

Страница 7: ...ber MODEL OPACH4212 EVAP MOTOR POWER CONNECTOR PLF SEE NOTE 2 ON WIRING DIAGRAM EVAPORATOR BLOWER MOTOR TRANSFORMER COMPRESSOR CONTACTOR CAPACITOR HIGH VOLTAGE POWER BLOCK THERMOSTAT CABLE RECEPTACLE...

Страница 8: ...OTOR SPEED IN COOLING MODE MOVE YELLOW LEAD FROM EM 4 TO 2 3 FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER 4 USE COPPER CONDUCTORS ONLY USE N E C CL...

Страница 9: ...e has fallen 3 degrees below the set point When in Heat Mode the thermostat determines the heating operation according to a preprogrammed switch over temperature When in HEAT mode the unit will operat...

Страница 10: ...per voltage plus the proper amperage to start the compressor If not contact an electrician Thermostat works Not Heating Check the thermostat to see if in HEAT mode Check the thermostat to see if the s...

Страница 11: ...subjected to any abnormal power conditions such as loss of power power surges voltage irregularities such as brown outs or phase loss on three phase equipment c any expenses including labor or materia...

Отзывы: