Powering and Starting the Unit - Follow the Instructions on Page 6 of this manual.

1. Make sure that the power supplied to the OPAC4212AH unit matches the power shown on 
   the unit nameplate, and that all power connections are correct and secured.

NOTE: Connecting the unit to an incorrect or faulty power source will void the warranty

2. Engage the MAIN POWER.  The unit is now controlled by the thermostat.

Cooling Mode

Begin by pressing the SYSTEM button until the thermostat is in COOL Mode.  Using the 
ARROW buttons, set the desired space temperature setpoint.  Remember, cooling will begin
once the space temperature has risen 3 degrees above the set point. 
 

NOTE:  The minimum setpoint in Cooling Mode is 55 degrees F

Heating Mode

Begin by pressing the SYSTEM button until the thermostat is in HEAT Mode.  Using the 
ARROW buttons, set the desired space temperature setpoint.  Remember, heating will begin
once the space temperature has fallen 3 degrees below the set point.  

Fan Mode

Pressing the FAN button, allows the user to switch Fan Modes from AUTO to ON.  In AUTO 
Mode, the fan will turn on and off as the unit cycles in Cooling or Heating Mode.  In ON Mode,
the fan will run continuously.

Circuit Breakers

The unit and the Auxiliary Heat Module are protected by line power circuit breakers.  
The unit breaker will trip at 50 Amps, while the Auxiliary Heat Module is protected by a separate 
40 Amp breaker, located behind the Blower Cover Panel.  The control access cover and blower 
access panel will need to be removed to gain access to the heater breaker as shown on Page 7.   

 Model Number:

MODEL:  OPAC4212AH

OPAC4212AH START UP AND OPERATION 

OA-EISM-OPAC4212AH- REV. 04212023

Page 9

Содержание OPAC4212AH

Страница 1: ...AIR CONDITIONER WITH AUXILIARY ELECTRIC HEAT ENGINEERING INSTALLATION AND SERVICE MANUAL OCEANAIRE Inc 1731 Wall Street Suite 100 Mount Prospect IL 60056 847 583 0311 oceanaire inc com OA EISM OPAC421...

Страница 2: ...AH unit As with all commercial air conditioning equipment it is recommended to have the OPAC4212AH sized and installed by a licensed specifying engineer and contractor in accordance with all local and...

Страница 3: ...s are equipped with brakes for the securing the unit on site as well as for storage and transit The Power Connection Main Breaker and duct connections are all located on the left side of the unit for...

Страница 4: ...OPTION 7 KW Electrical Heat ELECTRICAL Locking 250V Power Connection Receptacle 50 Amp Circuit Breaker for Unit Power Protection 40 Amp Auxiliary Heat Breaker 24 VAC Thermostat with 50 ft detachable...

Страница 5: ...MAIN BREAKER BOX OPAC4212AH LEFT SIDE OPAC4212AH DETAILS THERMOSTAT STORAGE COMPARTMENT MAY BE LOCATED IN OTHER AREA OPAC4212AH REAR CONTROLS ACCESS PANEL EVAP BLOWER ACCESS PANEL THERMOSTAT CABLE REC...

Страница 6: ...0 VAC Receptacle POWER INLET Hubbell CS8275 POWER CONNECTOR Hubbell CS8264C or Equivalent 6 Check that all power connections are secure and that the Main Breaker is ON up position 7 Connect Supply Pow...

Страница 7: ...Number MODEL OPAC4212AH EVAP MOTOR POWER CONNECTOR PLF SEE NOTE 2 ON WIRING DIAGRAM EVAPORATOR BLOWER MOTOR TRANSFORMER COMPRESSOR CONTACTOR CAPACITOR THERMOSTAT CABLE RECEPTACLE OPAC4212AH CONTROLS O...

Страница 8: ...OW VOLTAGE JUNCTION BOX FEMALE PLUG CONNECTOR IN HEATER BOX RUN CAPACITOR FOR COMPRESSOR AND FAN TRANSFORMER HIGH PRESSURE SWITCH NOTES 1 REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIG...

Страница 9: ...pressing the SYSTEM button until the thermostat is in HEAT Mode Using the ARROW buttons set the desired space temperature setpoint Remember heating will begin once the space temperature has fallen 3...

Страница 10: ...ed or wait until the space warms Check the incoming power for proper voltage plus the proper amperage to start the compressor If not contact an electrician Thermostat works Not Heating Check the therm...

Страница 11: ...ubjected to any abnormal power conditions such as loss of power power surges voltage irregularities such as brown outs or phase loss on three phase equipment c any expenses including labor or material...

Страница 12: ...OA EISM OPAC4212AH REV 04212023 OCEANAIRE Inc 1731 Wall Street Suite 100 Mount Prospect IL 60056 847 583 0311 oceanaire inc com NOTES...

Отзывы: