Rel 8.1. October 2009
ATTACHING M101A TO A GOGGLE
Connect the M101A to the left or right side strap of the goggle as indicated
in Figure 3. Make sure that the strap sits entirely inside the strap housing on
the M101A. Check that the M101A slides freely on the strap.
Chapter 4
INSTALLING THE BATTERY
All the models work with a conventional 9V alkaline battery.
Do not use manganese batteries.
(1) Unscrew the two screws on the cover and remove the cover and cap with
its O-ring.
(2) Remove the dead battery from the main compartment.
(3) Install a new battery in the compartment, making sure that the polarity is
correct (see label on the inside).
(4) Clean and lubricate the O-ring. Reposition the cap as indicated in figure
9. The cap MUST face the right direction. The flat side of the battery cap
must be on the rear side (when wearing the mask with the GSM) in order to
get a good seal.
(5) Holding the cap in position, position the cover and screw the two screws
in place until they are tight. DO NOT OVER-TIGHTEN the screws!
5
fig. 3
fig. 8
fig. 7
membrane
fig. 9a
Flat side
fig. 9b