background image

 4 

 

Ocean Matrix 

www.oceanmatrix.com 

 

Ocean Matrix OMX—01HMBT0010 

RS232 STANDARD SERIAL CONTROLLER TERMINAL

 

 

Download the control software. Find the download on the Ocean Matrix website on the 

OMX-01HMBT0010 

product page. 

 

1.  Copy the control software file to the control PC 
2.  Set the following parameters: 



COM Number 



Baud Rate: 2400, 4800, 9600, 19200, 38400, 57600 or 115200 



Data Bit: 8 



Stop Bit: 1 



Parity Bit: None 

RS232 COMMAND 

Signal Switching  

TRANSMITTER CONTROL 
Set the following Commands: 



Baud Rate: 9600 



Data Bit: 8 

Command   Function  

Feedback Example  

50701%  

Switch to HDMI IN 1 input.  

SWITCH TO HDMI1  

50702%  

Switch to HDMI IN 2 input.  

SWITCH TO HDMI2  

50710%  

Enable auto-switching mode.  

AUTO SWITCHING  

50711%  

Disable auto-switching mode.  

MANUAL SWITCHING  

50712%  

Get the signal switching mode.   AUTO SWITCHING or MANUAL SWITCHING 



Stop Bit: 1 



Parity Bit: None 

CEC Command—Display must Support CEC 
Note:
 Not all displays/monitors with CEC adhere fully to all command functions. 

Command   Function  

Feedback Example  

50730%  

Volume Up on Display 

CEC VOLUME INCREASE 

50731%  

Volume Down on Display CEC 

VOLUME 

DECREASE 

50732%  

Mute 

CEC VOLUME MUTE 

50733%  

Display ON 

CEC DISPLAY ON 

50734%  

Display OFF 

CEC DISPLAY OFF 

HDCP Command 

Command   Function  

Feedback Example  

50709%  

HDCP Mode 

HDCP: ON 
HDCP: OFF 

50713%  

HDCP Status 

HDCP 2.2 
NO HCDP 

Factory Default 

Command   Function  

Feedback Example  

50617%  

Restore Factory Default 

FACTORY RESET 

50699%  

Firmware Version 

VERSION Vx.x.x 