4
Ocean Matrix
www.oceanmatrix.com
Ocean Matrix OMX—01HMBT0010
RS232 STANDARD SERIAL CONTROLLER TERMINAL
Download the control software. Find the download on the Ocean Matrix website on the
OMX-01HMBT0010
product page.
1. Copy the control software file to the control PC
2. Set the following parameters:
COM Number
Baud Rate: 2400, 4800, 9600, 19200, 38400, 57600 or 115200
Data Bit: 8
Stop Bit: 1
Parity Bit: None
RS232 COMMAND
Signal Switching
TRANSMITTER CONTROL
Set the following Commands:
Baud Rate: 9600
Data Bit: 8
Command Function
Feedback Example
50701%
Switch to HDMI IN 1 input.
SWITCH TO HDMI1
50702%
Switch to HDMI IN 2 input.
SWITCH TO HDMI2
50710%
Enable auto-switching mode.
AUTO SWITCHING
50711%
Disable auto-switching mode.
MANUAL SWITCHING
50712%
Get the signal switching mode. AUTO SWITCHING or MANUAL SWITCHING
Stop Bit: 1
Parity Bit: None
CEC Command—Display must Support CEC
Note: Not all displays/monitors with CEC adhere fully to all command functions.
Command Function
Feedback Example
50730%
Volume Up on Display
CEC VOLUME INCREASE
50731%
Volume Down on Display CEC
VOLUME
DECREASE
50732%
Mute
CEC VOLUME MUTE
50733%
Display ON
CEC DISPLAY ON
50734%
Display OFF
CEC DISPLAY OFF
HDCP Command
Command Function
Feedback Example
50709%
HDCP Mode
HDCP: ON
HDCP: OFF
50713%
HDCP Status
HDCP 2.2
NO HCDP
Factory Default
Command Function
Feedback Example
50617%
Restore Factory Default
FACTORY RESET
50699%
Firmware Version
VERSION Vx.x.x