Table of Contents

Warranty.................................................................................................................................................................1

Safety Information..................................................................................................................................................1

Overview................................................................................................................................................................2

System Description.................................................................................................................................................2

Unpacking and Assembling.....................................................................................................................................3

Operation...............................................................................................................................................................4

Installing a Needle..................................................................................................................................................5

Bending the Needle................................................................................................................................................5

Loading Gutta Percha.............................................................................................................................................5

Expressing Gutta Percha..........................................................................................................................................5

Sterilization Instructions.........................................................................................................................................6

Maintenance...........................................................................................................................................................7

Error Codes..........................................................................................................................................................10

Handpiece Attachment/Detachment......................................................................................................................10

Theory of Operation.............................................................................................................................................10

Frequently Asked Questions..................................................................................................................................11

Factory Repair/Contact Us....................................................................................................................................12

Replacement Parts................................................................................................................................................12

Material Data Safety Sheet....................................................................................................................................13

Manufactured By:

Obtura Spartan

2260 Wendt Street

Algonquin, IL 60102

(800) 344-1321

www.obtura.com

Authorized Representative in EEA:

Quality Endodontic Distributors Ltd.

Units 10/12 Orton Enterprise Centre

Bakewell Road, Orton Southgate

Peterborough, PE2 6XU, UK

Tel: 01733 404 999

Fax: 01733 361 243

OPERATOR’S

MANUAL

HEATED

 GUTTA PERCHA 

SYSTEM

Guidance and Manufacturer’s Declaration – Electromagnetic Immunity 

The Obtura III Max Heated Gutta Percha System is intended for use in the electromagnetic environment specified 

below. The customer or the user of the Obtura III Max Heated Gutta Percha System should assure that it is used in 

such an environment. 

Immunity test 

IEC 60601 

Test Level 

Compliance 

Level 

Electromagnetic environment 

– guidance 

Conducted RF 
IEC 61000-4-6 

Radiated RF 
IEC 61000-4-3 

3 Vrms 
150 kHz to 80 MHz 

3 V/m 
80 MHz to 2.5 GHz 

3 V 

3 V/m 

Portable and mobile RF communications equipment 
should be used no closer to any part of the Obtura III 
Max Heated Gutta Percha System including cables, 
than the recommended separation distance 
calculated from the equation applicable to the 
frequency of the transmitter. 

Recommended separation distance 

d

 

= 1.2 √

d

 

= 1.2 √

P  

80 MHz to 800 MHz 

d

 

= 2.3 √

P  

800 MHz to 2.5 GHz 

where 

P

 is the maximum output power rating of the 

transmitter in watts (W) according to the transmitter 
manufacturer and 

d

 is the recommended separation 

distance in meters (m). 

Field strength from fixed RF transmitters, as 
determined by an electromagnetic site survey, 

a

should be less than the compliance level in each 
frequency range. 

b

Interference may occur in the vicinity of equipment 
marked with the following symbol. 

NOTE 1     At 80 MHz and 800 MHz, the higher frequency range applies 

NOTE 2     These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption 
and reflection from structures, objects and people. 

a  

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile   
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. 
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be 
considered. If the measured field strength in the location in which the Obtura III Max Heated Gutta Percha System is 
used exceeds the applicable RF compliance level above, the Obtura III Max Heated Gutta Percha System should be 
observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, 
such as re-orienting or relocating the Obtura III Max Heated Gutta Percha System. 

Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. 

GUIDANCE AND MANUFACTURER'S DECLARATION

       

1

7

EMC Table..........................................................................................................................................................15

Содержание III MAX

Страница 1: ...ATOR S MANUAL Welcome to the Your essential guide to our clinically advanced Heated Gutta Percha System 2260 Wendt Street Algonquin IL 60102 800 344 1321 www obtura com 2011 Obtura Spartan 57412G 10 1...

Страница 2: ...supplied by Obtura Spartan only This equipment contains no electrical parts serviceable by the user Environmental Conditions Symbol SN PN M Symbol Description Description Ambient Temperature 10 C to...

Страница 3: ...ha System is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Obtura III Max Heated Gutta Percha System can help prev...

Страница 4: ...equation applicable to the frequency of the transmitter Recommended separation distance d 1 2 P d 1 2 P 80 MHz to 800 MHz d 2 3 P 800 MHz to 2 5 GHz where P is the maximum output power rating of the...

Страница 5: ...ies Use of other cables or accessories has the potential to damage the device or affect compliance to EMC standards 9 Cables and Accessories Handpiece Cord Max length 8 IEC 60601 1 Power Cord Max leng...

Страница 6: ...and difficult to move the plunger due to a buildup of old hardened gutta percha Overview Congratulations on your purchase of the Obtura III MAX Please read the entire manual prior to using this unit H...

Страница 7: ...cause irritation of the respiratory tract y nausea dizziness or headache Product has a low order of acute oral toxicity but ingestion of large quantities may cause nausea vomiting and gastrointestinal...

Страница 8: ...ge from the previously set temperature to the new set point temperature Note preset memories are saved even during power failure The Obtura III MAX requires approximately 120 seconds to heat from ambi...

Страница 9: ...t for the gutta percha to come up to full operating temperature before attempting to express material that is too cool will require much more pressure or may be impossible to pass through a small diam...

Страница 10: ...ol unit case via a standard power supply connector Frequently Asked Questions Q How often should the unit be cleaned A The Obtura III MAX should be cleaned at the end of each day or procedural session...

Страница 11: ...pring loaded pawl moves the shaft forward The heater assembly is directly connected to the handpiece shell providing a straight through path for gutta percha warming it in the process 10 ERROR CODES M...

Страница 12: ...that bushing rotation ceases To install the handpiece bushing slide it in the opening at the rear of the handpiece diagram K and turn clockwise until resistance is felt The handpiece bushing should b...