background image

 

OBSTA

 

2 rue Troyon 92316 Sèvres Cedex FRANCE 

www.obsta.com 

 

Page 
1/18

 

 

 

Edition October 2020

 

 

  

 

 

OBSTAFLASH Led 

 

 110-240VAC 

 

 

 

 

 

 
 
 
 

INSTALLATION AND OPERATION GUIDE

 

 
 
 
 
 
 
 
 
 
 
 

 

Содержание 110-240VAC

Страница 1: ...OBSTA 2 rue Troyon 92316 S vres Cedex FRANCE www obsta com Page 1 18 Edition October 2020 OBSTAFLASH Led 110 240VAC INSTALLATION AND OPERATION GUIDE...

Страница 2: ...White and Red medium intensity type A B 110 230VAC 10 113725U In option photocell P N100755 wireless GPS P N113746 inside cabinet 110VAC 230VAC side lights L 810 NAVILITE FAA P N113969 battery cabine...

Страница 3: ...n misused or abused in any manner or repairs attempted thereon III written notice of the failure within the warranty period is forwarded to OBSTA and the directions received for properly identifying i...

Страница 4: ...includes 3 flash heads with a total of 6 led glass and aluminum projectors a stainless steel power supply inside Each projector includes 1 red LED circuit and 1 red LED circuit in series with 2 other...

Страница 5: ...OBSTA 2 rue Troyon 92316 S vres Cedex FRANCE www obsta com Page 5 18 Figure 1 1 FLASHHEAD COMPONENT LOCATIONS...

Страница 6: ...te de puissance LED blanche PC2 Carte de puissance P N 113741 Powercard white LED Carte de puissance LED blanche PC1 white LED Powercard LED blanche P N 113741 P N 113741 Powercard white LED Carte de...

Страница 7: ...OBSTA 2 rue Troyon 92316 S vres Cedex FRANCE www obsta com Page 7 18 Figure 1 5 POWER CABINET ENCLOSURE...

Страница 8: ...per minute in red depending on G or H version Master slave configuration slaves lights can be synchronized with 1 master light and one photocell and 3x1 5mm shielded cable 1 3 1 Electrical input for f...

Страница 9: ...3 Operating environment Operating temperature 40 C to 55 C Humidity 95 relative humidity 1 3 4 System operating status envitronment On the command card inside flash head 10 luminous indicators as per...

Страница 10: ...cation 2 2 2Connection of the beacon to the power supply 2 2 2 2 Connection of the interconnecting cable P N 113762 to the junction box option The interconnecting cable P N113762 provided by OBSTA com...

Страница 11: ...nting inside power cabinet If included the GPS interface comes with an external magnetic antenna The cable of the antenna is to be connected in the GPS interface with a jack plug Input voltage 24 48Vd...

Страница 12: ...no touch Do no touch Do no touch Do no touch Sur ge Protector Parafoudre CITEL 10 9 8 7 6 5 4 3 2 1 48V 48V 48V 11 R E LA Y P WR C TR L G N D P N 113744 1 234 5 6 1 2 3 L N Test Day 0 RemoteI Test Ni...

Страница 13: ...L L N T es t Day Remote T es t Night 1 PC5 C arte de puissance LE D blanche PC2 C arte de puissance P N 113741 P ow er card w hite LE D C arte de puissance LE D blanche PC1 w hite LE D P ow er card LE...

Страница 14: ...ircuits Positive poles of all led circuits are connected together There are 6 power cards that control the current of 12 white LED circuits negative poles are blue and white wires from each projector...

Страница 15: ...up in master mode dipswitch n 1 on on the command card creates a top sync pulse indicated by D14 and that can be sent for other flash heads from terminal 1 when set up in slave mode dipswitch n 1 on o...

Страница 16: ...nd card red led the red indicator is off indicate day time the red indicator is on indicate night time or no signal from satellite When the GPS is synchronized the top sync pulse and 0 48VDC day night...

Страница 17: ...cording to the wiring diagram Replace photocell or command card if necessary Some luminous indicators D6 to D12 are blinking red in day and or night mode Check the wiring connection on the related pow...

Страница 18: ...ojectors do not work it means that almost 2 projectors on each red led circuit are defective It is possible to connect 2 red projectors in serial instead of 3 on the power card red1 test all projector...

Отзывы: