OMC-131 True wind display
Users’ manual
V1.14
Page 23
TDC-April-2017
Select one of the items with the numbers in
front of the option.
5.1 Input device
With the given options the OMC-131 can be
set to customer needs.
If "Select input device" is selected the menu on
the right will appear on the screen. The menu
shows the actual situation with the words placed
in brackets. This actual situation can be changed
by selecting a number.
The OMC-131 can handle the information from
two wind sensors. If only one wind sensor is
used the second wind sensor is disabled as
shown.
"in use" indicates the option is not
selectable since it is in use by
another function!
If you want to enable this function
you will need to disable the other
function first.
If number "1" or "2" has been selected a new
menu will appear as shown on the right.
With this menu it is possible to select the type
of wind sensor used with the system and the
transmission speed the sensor is transmitting
its information to the rack.
The selected items are marked with an
asterisks between the number and the texts.
In the menu the Observator Instruments
OMC-160 NMEA wind sensor has been
selected with a communication speed of
4800 bps.
The second wind sensor has been disabled.
If the settings have been made press "0" to return to the previous menu.