background image

   PAGE 12

OBLICA

 | PAXFOCUS INSTALLATION AND USER MANUAL

4. OPERATION

4.1  What you should burn

•  Untreated, air dried hardwood 
•  Split logs with a humidity content of less than 20%

4.2  Do not burn

•  Trash
•  Painted plastic 
•  Coated or preservative treated wood
•  Waste or black coal 
•  Inflammable liquids 
•  Fire gels 
•  Moist wood with a residual humidity content of more than 20% (this may cause soothing of the chimney).

WARNING: 

 • Do not use flammable liquids or aerosols to start or rekindle the fire. 
•   Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating. 
•   Do not store fuel within prescribed installation clearance distances.
•   The use of some types of preservative-treated woods as a fuel can be hazardous.

IMPORTANT: 

•  Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee.
•  The maximum load capacity for the PaxFocus is 20kg of wood.
•  Burning only seasoned hardwood helps to protect the environment and lower emissions.
For details of a wood supplier in your area please call our office on 03 9416 0400 or email [email protected].

Содержание PaxFocus

Страница 1: ...PAXFOCUS INSTALLATION AND USER MANUAL 1 TECHNICAL DATA 2 2 PRE INSTALLATION 3 3 INSTALLATION 5 4 OPERATION 13 5 TESTING 14 Keep for future use OBLICA 200 Argyle St Fitzroy VIC 3065 03 9416 0400...

Страница 2: ...CONDITIONS Nominal thermal output 5kW Efficiency 46 1 WEIGHT AND DIMENSIONS Firebox diameter W950mm x D650mm Firebox weight 66Kg Flue diameter 219mm Flue weight 16Kg meter External flue kit Triple ski...

Страница 3: ...nstall the internal flue and engage the firebox Ensure the floor has adequate protection CAUTION Using components or parts other than those provided by the manufacturer or modifying the specification...

Страница 4: ...r window frames must be treated as combustible surfaces see 2 3 Aluminium frames can be treated as non combustible surfaces see 2 2 2 PRE INSTALLATION CONTINUED Distances de s curit par rapport aux ma...

Страница 5: ...device PLASTER CEILING MINIMUM GAP 150mm 25mm 3 1 Installing the suspension bracket You must leave a 25mm clearance gap between the flue and the ceiling This gap will be covered by the ceiling Flange...

Страница 6: ...L 3 INSTALLATION CONTINUED LOWER FLUE 219mm PLASTER CEILING MINIMUM GAP 25mm CONNECTOR CEILING FLANGE RUBBER FLASHING TRIPLE SKIN FLUE 200 X 250 X 300 8 x 10 x 12 CHINAMAN HAT Anti Down Draft device 1...

Страница 7: ...installed as per Australian standards see diagrams below The top of the flue must be 400mm higher than the highest point of the roof Alternatively there must be a minimum distance of 3 meters from any...

Страница 8: ...LICA PAXFOCUS INSTALLATION AND USER MANUAL 3 INSTALLATION CONTINUED 1 2 4 3 atelier dominique imbert 2013 paxfocus 07 R 2 4 atelier dominique imbert 2013 paxfocus 29 07 1313 07 RRF 1625 2 4 3 2 1 2 4...

Страница 9: ...TION AND USER MANUAL 3 INSTALLATION CONTINUED 5 6 8 7 atelier dominique imbert 2013 paxfocus 07 RR 5 6 8 7 3 5 6 8 7 atelier dominique imbert 2013 paxfocus 29 07 1313 07 RRF 1625 6 8 5 7 6 8 Needs mor...

Страница 10: ...stible material with non combustible material laid directly onto the concrete Joist 200mm Insulative board 6mm non combustible finish N Concrete Combustible floor eg timber Joist 200mm 200mm Insulativ...

Страница 11: ...otector Combustible floor eg timber 300 200 FIREBOX WALL FLOOR PROTECTOR LAID ON CONCRETE TOP VIEW 3 INSTALLATION CONTINUED Non combustible finish eg tiles Concrete 200mm Combustible floor eg timber n...

Страница 12: ...s to start or rekindle the fire Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of...

Страница 13: ...Extended to PaxFocus by Vipac Laboratory WORK REQUESTED Measure CO2 levels as outlined in AS NZS 4013 1999 to determine if appliance is excluded from full testing to this standard TEST DATES 09 06 20...