4. FRAMING & CLADDING

MODEL 
(all measurements in mm)

A

B

C

D

60 x 80

222

778

475

1092

75 x 65

222

1005

473

989

75

222

989

473

773

110

254

1349

475

715

110H

254

1367

475

915

130

254

1519

475

715

130H

254

1519

475

915

150

254

1770

475

715

150H

254

1770

475

915

170

254

1970

475

715

170H

254

1970

475

915

200

254

2210

475

715

200H

254

2210

475

915

250

254

2683

475

764

250H

254

2683

475

915

TR90

254

1170

689

978

TR110

254

1360

689

1059

CLADDING FOR METAL STUDS 

external cladding

The framing structure must be clad

 externally

 with non 

combustible material and gaps sealed with a non-combustible fire 
proof sealant. We recommend the fireplace to be in position and 
flued prior to cladding.

OPTION 1: METAL STUDS FRAMING 

(Preferred option)

The frame must be designed to carry the entire weight of the finished wall with no component being supported by the fireplace.   

  CLADDING 

REQUIREMENTS 
ARE DIFFERENT 
FOR TIMBER STUD 
AND METAL STUD 
FRAMING. PLEASE 
READ INSTRUCTIONS 
CAREFULLY BEFORE 
FRAMING. 

Содержание ORTAL 75x65

Страница 1: ...ORTAL SINGLE SIDED FIREPLACES SPECIFICATIONS PRODUCT GUIDE...

Страница 2: ...proved DuraVent flue system as specified Consult the relevant authority to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure that t...

Страница 3: ...th 7x1 275mm orifice 37MJ h 0 69kPA 0 73kPA 0 26kPA 125 205mm TRAD 110 B100 Marked 1200 with 7x1 275mm orifice 37MJ h 0 69kPA 0 73kPA 0 26kPA 125 205mm 130 130H B100 Marked 1200 with 7x1 275mm orifice...

Страница 4: ...8 130 1368 420 692 1278 x 350 130 H 1368 420 892 1278 x 550 150 1636 420 692 1528 x 350 150 H 1636 420 892 1528 x 550 170 1813 420 692 1528 x 350 170 H 1813 420 892 1528 x 550 200 2076 420 692 1968 x...

Страница 5: ...H 254 2683 475 915 TR90 254 1170 689 978 TR110 254 1360 689 1059 CLADDING FOR METAL STUDS external cladding The framing structure must be clad externally with non combustible material and gaps sealed...

Страница 6: ...0 689 1059 662 CLADDING FOR TIMBER STUDS WITH METAL SECTION external cladding internal cladding OPTION 2 TIMBER STUDS WITH METAL SECTION The frame must be designed to carry the entire weight of the fi...

Страница 7: ...EXHAUST AND AIR INTAKE HOT AIR FLOW HEAT RELEASE AS REVEAL VENTING Convection air outlet A convection air outlet is required for all Ortal fireplaces This allows for heat building up within the firep...

Страница 8: ...rvices We recommend a minimum size of 200x200mm However access panels are not the only option for servicing the fireplace operation mechanisms A technician may also service the fireplace controls by g...

Страница 9: ...PAGE 9 OBLICA SPECIFICATIONS AND PRODUCT GUIDE 7 TV CLEARANCES 305mm MIN 305mm MIN RECESSED INSTALLATION FLUSH INSTALLATION...

Страница 10: ...AL DECORATIVE ROOM SEALED GAS APPLIANCES HAVE BEEN TESTED AND APPROVED BY AGA IAPMO R T FOR USE WITH NATURAL GAS NG Australian Standard AS5263 0 2016 Decorative Gas Log and Other Fuel Effect Appliance...

Отзывы: