Weekly
SET A PROGRAM:
•
PROGRAM No.
•
DURATION
•
START TIME
•
CONSTANT FLOW RATE
•
VOLUME
•
DAYS OF ACTIVITY
This menu allows you to set the data
of each program (max 13 programs).
You can set the constant flow rate or
volume of constant flow rate to be
transferred, transfer duration, start
time, and days of activity.
We recommend not overlapping the
programs.
ACTIVE PROGRAMS
This menu shows the active
programs and allows you to activate
or deactivate them.
3.3
Partialisation
In the event that the required flow rate is 30% lower than the set flow rate during calibration, the
pump starts the partlialisation stage. This stage consists in:
1.
Work stage, in which the pump runs at 30%
2.
Pause stage
The duration of these two stages are calculated by the firmware so as to obtain the flow rate
required.
The minimum flow rate provided is 1% the maximum flow rate. The pump fails to start if this value
is not reached.
3.4
Settings
The setting menu is shown in Figure 12 and allows you to open all the functions described in Table
.
Figure 12 Settings
Table 7 Settings
Modes
Input parameters
Description
Calibration
TEST DURATION
MOTOR POWER
MAXIMUM MOTOR PHASE CURRENT
MOTOR FREQUENCY
This mode allows you to test the
pump’s flow rate at the maximum
frequency. The pump capacity screen
appears at the end of the test.