Remember: 

 
Always perform an arc flash risk assessment to determine the potential arc flash incident energy 
exposure level. Only use arc flash PPE with an arc rating (ATPV or E

BT

) that is equal to or greater 

than your potential arc flash incident energy level. 
 

Compliance: 

 
Oberon arc flash PPE is compliant with every applicable Standard necessary as per NFPA 70E and 
CSA Z462.   
 
This includes: 

  ASTM F2178, Standard Test Method for Determining the Arc rating of Face Protective Products 

  ANSI Z87.1, Practice for Occupational and Educational Eye and Face Protection. 

  ASTM F1506, Standard Performance Specification for Textile Material for Wearing Apparel for 

Use by Electrical Workers Exposed to Momentary Electric Arc and Related Thermal Hazards.  

  ASTM F1959, Standard Test Method for Determining the Arc Rating of Materials for Clothing. 

 

Arc Flash Suit Hood Specification: 

 

  Clear “True Color Grey” (TCG) hood shield window. 

  Nomex thread on all seams and embroidery on the outside to identify the protection level and 

TCG Series. 

  Hood shield window made of polycarbonate material  providing  high impact and high mass 

protection for maximum protection from shrapnel, projectiles and flying debris. ANSI Z87.1+ 
Certified. 

  Anti-scratch coating on the outside of the shield window. 

  Anti-fog coating on the inside of the shield window. Anti-fog coating must be activated before 

each use. See instructions below. 

  Hanging loop on the top of the hood. 

  Optional hood ventilation system (HVS) for fresh air to optimize worker comfort. External 

components constructed of FR plastic to prevent component ignition in the event of an arc flash 
accident. 

  Optional LED head lamp for task lighting necessary in most work tasks. 

  Oberon brand CSA Z94.1 certified Type 1 Class E hard hat with ratchet head suspension is 

included with all standard TCG Series hoods. Alternative adapters are available and might have 
been supplied. Adapters must match the hard hat otherwise they will not fit and/or break. 

 

Arc Flash Suit Coat & Bib-Overall Specification: 

 

  Nomex thread embroidery on the outside to identify the protection level and TCG Series. 

  High visibility stripping on the arms and legs provide enhanced visibility in low light and helps 

rescue personnel identify a worker following an arc flash incident. 

  Compliant label includes: 

o

  Manufacturer 

Содержание TCG Series

Страница 1: ...OBERON USER GUIDE Arc Flash Suit Care Use 1 TCG Series Rev 2 Oberon s TCG Series Arc Flash Suits Jim Pollard Canadian Sales Manager Oberon Company 519 939 3204 jim oberoncompany com www arcflash com...

Страница 2: ...mportant Warning 3 Remember 4 Compliance 4 Arc Flash Suit Hood Specification 4 Arc Flash Suit Coat Bib Overall Specification 4 Sizing Selection 5 Pre Use Inspection 5 How to Wear an Arc Flash Suit 6 I...

Страница 3: ...tructions Storage How to Disassemble Assemble an Arc Flash Suit Hood Cleaning Repairs Caution Flammable contaminants will reduce the thermal performance of any flame resistant arc rated garment Wash g...

Страница 4: ...shield window made of polycarbonate material providing high impact and high mass protection for maximum protection from shrapnel projectiles and flying debris ANSI Z87 1 Certified Anti scratch coating...

Страница 5: ...zes short tall and extra tall When using a sizing kit it s important to make sure you have the same PPE on that you would when using the suit Don t wear street clothing during sizing If you intend on...

Страница 6: ...not broken These parts are made with plastic so if they break it s easy to buy replacements Inspect the fabric inside and out to make sure it s not ripped frayed no holes any damage or contamination F...

Страница 7: ...it doesn t fit right do not proceed to wear it The FR knit cuffs should fit to your wrists The pant leg bottoms should be long enough to completely cover your legs down to your ankles You re only as w...

Страница 8: ...tures instructions At the back of the hood remove the fan unit by twisting the hose coupling to the left detach the fan remove the fan pack from the mounting strap and then place it aside Pay attentio...

Страница 9: ...e hood pull the FR hose out the port hole There is a protective flap inside the hood so find the top and pull the hose down Reach around on the outside at the back and pull the coupling and hose throu...

Страница 10: ...ould become plugged by lint If this has already happened comb out the hook side of the FR Velcro Follow the Oberon label for instructions on how to properly launder your suits General cleaning require...

Страница 11: ...ase Dry cleaning shall be done according to the care labeling by usual 2 bathprocedure Boosters should only be used in extreme situations and only with reduced mechanism Dry cleaning shall only be don...