background image

Installation Guide / 

Guía de instalación

 

for Oberon Model 1018

-

00

 

para Modelo Oberon 1018

-

00

 

 

 

 

Mounting Solutions for WiFi Access Points

 

"Oberon" and all other marks where denoted are trademarks of Oberon Inc.  

©

1999

-

2022 Oberon Incorporated. All rights reserved.

 

"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc.  ©1999

-

2022 Oberon Incorporated. Todos los derechos reserve.

 

EPN 3977 

-

 Rev. 2/1/2022

 

Oberon’s Model

 

1018

 

Envelope™ recess wall mount enclosures conceal 

Wi

-

Fi and Small Cell APs, antennas, and associated cabling in areas 

where it is desirable to hide wireless equipment without compromising 
performance. Wireless equipment needs to be placed where the users 
are, in order to provide effective wireless coverage. But property owners 
sometimes want the AP and antennas to “disappear”. The 1018 recesses 
the AP or antenna into a shallow plastic box, and has a low profile, 
paintable, snap

-

on cover. This rugged all plastic enclosure is virtually 

transparent to wireless signals so there is minimal impact on wireless 
coverage. The

 

1018 is UL listed for use in commercial spaces, and is 

large enough for most vendors Wi

-

Fi and small cell access points and 

antennas.

 

Los gabinetes de montaje en pared empotrados modelo 1018 Enve-
lope™ de Oberon ocultan Wi

-

Fi y AP de celdas pequeñas, antenas y 

cableado asociado en áreas donde es deseable ocultar equipos inalá-
mbricos sin comprometer el rendimiento. El equipo inalámbrico debe 
colocarse donde están los usuarios, para proporcionar una cobertura 
inalámbrica efectiva. Pero los propietarios a veces quieren que la AP y 
las antenas "desaparezcan". El 1018 empotra el AP o la antena en una 
caja de plástico poco profunda y tiene una cubierta a presión de bajo 
perfil, pintable. Este robusto recinto de plástico es prácticamente trans-
parente a las señales inalámbricas, por lo que tiene un impacto mínimo 
en la cobertura inalámbrica. El 1018 está homologado por UL para su 
uso en espacios comerciales, y es lo suficientemente grande como para 
la mayoría de los proveedores de Wi

-

Fi y antenas y puntos de acceso de 

celdas pequeñas.

 

Instructions are for typical install conditions. Instructions may not be 
correct for all installations due to building design, construction ma-
terials or methods used and/or building or site conditions. Consult a 
contractor or architect for recommendations. For product questions 
call (+1) 877

-

867

-

2312.

 

 

Las instrucciones son para condiciones típicas de instalación. Las 
instrucciones pueden no ser correctas para todas las instalaciones 
según el diseño del edificio, materiales de construcción o métodos 
utilizados, o condiciones del edificio o del lugar. Consulte a un con-
tratista o arquitecto para obtener recomendaciones. Si tiene 
preguntas con respecto al producto, llame al (+1) 877

-

867

-

2312.

 

Thank you for choosing Oberon. 

/ Gracias por elegir Oberon.

 

WARNING 

/ ADVERTENCIA

 

Follow manufacturer's instructions for hand or power tools. 
Always use safety glasses. Failure to do so may result in injury 
and/or product damage.

 

Siga las instrucciones del fabricante para herramientas manu-
ales o eléctricas. Utilice siempre gafas de seguridad. Si no lo 
hace, podría producirse lesiones y / o daños al producto.

 

WARNING 

/ ADVERTENCIA

 

Use caution when working at elevated heights. Follow manu-
facturer's instructions for ladders and/or scaffolding. Failure to 
do so may result in injury or death.

 

Tenga cuidado al trabajar a alturas elevadas y alrededor de las 
aberturas de la unidad. Siga las instrucciones del fabricante 
para laddors y / o andamios. Si no lo hace, podría causar le-
siones o la muerte.

 

Important Information for Model 1018 

/ Información importante para el modelo 1018

 

1. The Cabinet System Communication is configured in the field by qualified service personnel.

 

 

 

2. This enclosure has a maximum operating ambient of 55º C (131º F). The temperature within the enclosure may not exceed this temperature, depending on 
power dissipation within enclosure.

 

3. A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be maintained for the safe operation of the 
equipment.

 

4. This product is intended to be installed by trained personnel.

 

5. Only Listed ITE products shall be installed within the enclosure.

 

6. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or replacement.

 

7. Maximum weight to be installed in the unit is 10 lbs.

 

8. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non

-

metal material that complies with UL 2043 or UL 1479.

 

9. All unused mounting holes should be sealed with tape or other material that complies with UL 1479.

 

10. AC Power is not to be used inside the enclosure.

 

11. A readily accessible disconnect device shall be incorporated in the building installation wiring.

 

12. See OSHPD approved installation drawing where applicable.

 

13. Enclosure 

 

must be installed in accordance with requirements of Local Building Codes, Canadian Electrical Code 

(CEC)

, CAN/CSA C22.1 and National 

Electric Code 

(NEC)

, NFPA 70. An appropriate disconnect device shall be provided as part of building installation.

 

1. La comunicación del sistema del gabinete está configurada en el campo por personal de servicio calificado.

 

2. Esta cubierta tiene un entorno máximo de funcionamiento de 55 °C (131 °F). La temperatura dentro de la cubierta no puede exceeder este valor, de-
pendiendo de la disipación de energía dentro de la misma.

 

3. Debe mantenerse un espacio mínimo de 1" entre la carcasa del punto de acceso y las paredes laterales de la cubierta para el funcionamiento seguro del 
equipo.

 

4. Este producto debe ser instalado por personal capacitado.

 

5. Solo productos homologados por ITE pueden instalarse dentro de la cubierta.

 

6. Este producto debe ser reparado por personal capacitado por el fabricante o devuelto al fabricante para su reparación o reemplazo.

 

7. El peso máximo a instalar en la unidad es de 10 libras.

 

8. Todos los perforados, las aberturas y los orificios deben sellarse con un tapón de metal o de un material no metálico que cumpla con las normas UL 2043 
o UL 1479.

 

9. Todos los orificios de montaje sin usar deben sellarse con cinta u otro material que cumpla con la norma UL 1479.

 

10. Dentro de la cubierta no debe utilizarse corriente alterna.

 

11. Se deberá incorporar un dispositivo de desconexión fácilmente accesible en el cableado de la instalación del edificio.

 

12. Consulte el plano de instalación aprobado por OSHPD donde corresponda.

 

13. El gabinete debe instalarse de acuerdo con los requisitos de los códigos de construcción locales, el código eléctrico canadiense (CEC), CAN/CSA C22.1 
y el código eléctrico nacional (NEC), NFPA 70. Se debe proporcionar un dispositivo de desconexión apropiado como parte de la instalación del edificio.

 

Important code and installation information. 

/ Información im-

portante sobre normas e instalación.

 

Read guide from beginning to end before beginning installation. Read all 
warnings and cautions before beginning unit installation. Check with your 
local building code official to identify and confirm compliance with local 
building code requirements. This installation guide covers installing your 
Model 1018 in a typical environment. The appropriate method for your 
installation may vary based on building design, application, and industry 
practices.

 

Lea la guía de principio a fin antes de comenzar la instalación. Lea todas 
las advertencias y precauciones antes de comenzar la instalación de la 
unidad. Verifique con un oficial de código edilicio de su localidad para 
identificar y confirmar el cumplimiento con los requisitos locales del códi-
go de edificación. Esta guía de instalación cubre la instalación del 
Modelo 1018 en un entorno adecuado. El método apropiado para la 
instalación puede variar según el diseño del edificio, la aplicación y las 
prácticas de la industria.

 

Tools Needed 

/ Herramientas necesarias

 

-

 Phillips

-

Head Screwdriver 

/ Destornillador Phillips

 

-

 Flat Head Screwdriver 

/ Destornillador de cabeza plana 

 

-

 Adjustable Wrench 

/ Llave adjustable

 

-

 (Optional) Conduit 

/ (Opcional) Conducto

 

Estimated Installation Time: 

 

Tiempo Estimado de Instalación:

 

15m

 

Parts Included 

/ Partes Incluidas

 

(1) Base Enclosure 

/ Recinto base

 

(1) Bottom Panel 

/ Panel inferior

 

(1) Cover 

/ Cubrir

 

(1) T

-

Bar Mount 

/ Montaje en barra en T

 

(4) Press Pads 

/ Almohadillas de prensa

 

(10) #6

-

19 x 3/8” Pan Head Thread

-

Forming Screws for Plastic 

/

 

Tornillos #6

-

19 x 3/8" de cabeza plana con forma de rosca para 

plástico

 

(4) #4

-

24 x 1

-

1/2” Pan Head Screws 

/

 

Tornillos de cabeza plana #4

-

24 x 1

-

1/2"

 

(1) Self

-

Centering 1 in. Trade Size Hole Plug, UL Listed 

/ Tapón 

de orificio de tamaño comercial autocentrante de 1 pulg., Listado 
por UL

 

(1) 1 in. Trade Size Conduit Connector 

 

Conector de conducto de tamaño comercial de 1 pulg.

 

Отзывы: