Installation Instructions 

Model Numbers 1015-00 and 1015-C 

 

(877) 867-2312   

   www.oberonwireless.com 

Part Number 2172, Rev. 1 

Oberon, Inc.  

••

  1315 South Allen Street  

••

  State College, PA 16801 

Copyright 2013 

 
Assembly Components: 
- Wall / Ceiling Enclosure, Model 1015-00 OR 1015-C assembly – 1 each 
- Keys for access door lock – 2 each 
- T-Bar Bracket – 1 each 
- #6 x 1/4" Flat Head Screw – 4 each 
- 1/2" O.D. Nylon Spacer – 2 each 
- #6 x 7/8" Screw – 2 each 
- #6 x 1/4" Screw – 2 each 
 
If any of these items are missing, contact your Oberon representative. 
 
Step 1 – Open the enclosure door and mount the access point’s mounting plate to the enclosure’s “T-Bar” mounting bracket 
using the access points instructions for mounting to a ceiling T-Bar if required. (Ref. Figure 1 and Figure 2).  
 
NOTE: Aruba Networks sells the 
mounting bracket separately. To 
install Aruba Networks Access 
Points you will need to purchase 
the mounting plate kit required 
for your AP. 
 
Use the provided spacer kit if 
the access point needs to be 
raised. 
 
Step 2 – When mounting the 
enclosure on a wall or hard lid 
surface, use the four (4) keyholes 
located on the four corners of the 
back box so that you will be able to 
mount the enclosure to the surface 
using screws and anchors (not 
included).  
 
Step 3A – If possible, the preferred 
mounting method is to place an 
Ethernet wall plate at the location 
where the enclosure will be 
mounted. There is a wall plate 
opening in the back of the 
enclosure to accommodate the 
wall plate. 
 
Step 3B – If it is not possible to place a wall plate where the enclosure is to be installed, decide the best location from which to 
bring in the Ethernet cable. There are two (2) 3/4” trade sized knockouts located on the top and bottom of the enclosure. Bring 
the Ethernet cable (and conduit if needed) into the enclosure in a way that best fits your application. 
 
NOTE: A surface mount box (or biscuit jack) and equipment cord can be conveniently mounted inside the Model 
1015. (Non-plenum rated cables can be used inside a plenum rated enclosure). Use an adhesive backed surface 
mount box. Consider bend radius of horizontal cable and equipment cord when attaching the surface mount box 
(Ref. Figure 3). 
  
Step 4 – Place the enclosure against the surface to which it will be mounted and mark the hole locations to drill pilot holes. 
 
Step 5 – Set the enclosure to the side and drill holes for wall anchors. Install the wall anchors and mount the enclosure. 

 
 
Step 6 – Bring in the Ethernet cable and attach to the access point. 
 
Step 7 – Attach the access point to the previously installed access point mounting plate, close and lock the door. Installation is 
now complete. 
 
 
Note: If mounting any Cisco access point using AIR-AP-BRACKET-1, use the provided #6 x 1/4" flat head screws. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 3 –Surface Mount Box Installation 

 

Figure 1 - 1015-00 Features 

Ethernet Knockout 

Vent Slots 

T-Bar Bracket 

Wall Plate Opening 

Keyhole Slot 

 

Figure 2 – Model 1015-00 Access Point Installation 