4.1.2 ICAO Stand-alone mode
Flashing mode is selected with DIPs 1-3.
Flashing rate is selected with DIPs 4-5.
DIP switch
Flash rate (FPM)
4
5
off
off
20
on
off
30
off
on
40
*
on
on
60
Photocell operation is configured with DIP6.
DIP switch
Photocell mode
6
off
Photocell is disabled
*
on
Photocell controls the light
DIP switch
Master/Slave mode
7
off
This device is slave
*
on
This device is master
DIP switch
Operating mode
8
off
Stand-alone
*
on
Modbus
* Factory default
DIP switch
Flashing mode
1
2
3
Night
off
off
off
2,000cd red, ICAO (flashing, check DIPs 4-5)
on
off
off
2,000cd red and infrared, ICAO (flashing, check DIPs 4-5)
*
off
on
off
2,000cd red (steady)
on
on
off
2,000cd red and infrared (steady)
off
off
on
200cd red and infrared, ICAO (flashing, check DIPs 4-5)
on
off
on
200cd red and infrared (steady)
off
on
on
Reserved
on
on
on
Reserved