PAGE 87-
11.7
11.7
11.7
11.7 Step Up
Step Up
Step Up
Step Up control
control
control
control
11.7.1 Step Up control
The Step Up function provides compensation for a reduction in current density caused by worn electrodes.
Step Up Finish process: “Last Step signal” is outputted from B6 on TB1 at a Switch to
the last step order and “Step Up Finish signal” is outputted
from B5 on TB1 at the end of last step.
Notes 1): With the parameter “Pr CurDetect” Enabled, Conduction Detection signal is
outputted from B6 on TB1 and therefore Last Step signal is not outputted.
2): With the parameter “Ps StepF2Out” Enabled, Step2’s Step.
Completion signal is outputted from B6 on TB1 and therefore Last Step signal
is not outputted.
3): With the parameter “Ps StepF2out” Enabled, Step1’s Step Completion signal is
outputted from B5 on TB1 and Other Series’ Step Completion signals are not
outputted.
4): The parameters “Pr CurDetect” and “Ps StepF2out” cannot be used when both
are “ON”. Take care of their settings.
CAUTION
CAUTION
CAUTION
CAUTION