English
Pump stops working
High temperature of the pump
due to lack of water
Check the water inflow - put the tube
into the container with 10 litre water
(per Minute)
Fluctuating pressure
1. Spray wand blocked
2. Pump body is sucking air
3. Impurities inside the pump
1. Clean the spray head with needle
2. Check if the high-pressure tube
connection is tight
3. Please consult after-sales service
The appliance does
not reach the operating
pressure
Trigger gun is unusable
Voltage
:
AC220V -240V
(
British standard
,
European standard
)
Working pressure: 1218psi
Water temperature: 0 ~ 40°C
Working temperature: 5-50°C
Power: 1600W
Max. pressure: 2030psi
Max. water inlet pressure
:
0.4Mpa
Flow rate: 420L/H
The appliance often
starts or stops to work
by itself (Stop at low
pressure)
Trigger gun is locked
1. Spring of the decompression
valve worn out
2. Water leakage of pump,
high-pressure hose, gun, etc
Please contact us
Unlock the gun
1. Spray wand blocked or worn
2. Inadequate supply of water
3. Inlet hose kinked
4. Filter blocked
5. Inlet hose blocked
1. Clean or replace spray wand
2. Check the inlet water flow-rate
3. Straighten out the hose
4. Clean the filter
5. Check the hose for leaks or blockages
Troubleshooting
Technical specification
Trouble
The appliance
fails to start up
Cause
Remedies
1. Poor contact with the plug
2. Socket issue
3. Extension power cord issue
4. Incorrect voltage
5. The power switch is off
6. Fuse falls off (If it’s used)
1. Connect to the plug
2. Try another socket
3. Try another extension cord
4. Check the voltage if it is correct
5. Turn on the switch
6. Replace fuse
5
Содержание CW6
Страница 1: ...CW6 Pressure Washers User Manual ON 1 OFF 0...
Страница 2: ...Made in China...