OPERATION 

 

STARTING THE PUMP 

To operate efficiently and to prevent damage to the pump there must be a free flow of water to 
and from the pump. Before starting ensure that: 

 

All pipe work is correctly sealed. 

 

Barrel  unions  on  the  inlet  and  outlet  are  hand  tightened  and  the  pipework  is  installed 
square to the pump. 

 

The pool/spa water level is at the correct height. 

 

That  all  appropriate  valves  are  open  and  there  is  nothing  preventing  the  flow  of  water 
through

 the system. 

 

1.

 

First prime the pump by removing the strainer basket lid and filling the strainer basket area 
with water. Replace the lid, ensuring that it seals on the large o-ring. 

2.

 

Connect to the power supply and switch on. 

3.

 

Allow the pump to run, so that any air trapped in the pipe work and pump may be expelled. 

4.

 

If prime is not established within approximately two minutes, as evidenced by a strong flow of 
water from the outlet, switch off the pump for 10 secs and repeat the procedure. Continued 

evidence of air under the hair and lint pot lid indicates an air leak in the suction piping work, 
which should be rectified to avoid pump damage. 

5.

 

If water flow through the pump is continuously tedious to obtain at start-up after cleaning the 

lint basket, then an examination of the system to establish a reason and correct the cause.  
(ie. Check valve, air leaks, faulty seal/s, crack lid. 
 
 

V SERIES VARIABLE SPEED CONTROL  

 

              

 

 

V Series 

Содержание V Series

Страница 1: ...ON AND OPERATION MANUAL V SERIES Variable 3 Speed Pool Spa Pump V SERIES V310 V390 V480 Head Office 62 Parkhurst Drive Knoxfield VIC 3180 T 03 9887 2131 New South Wales Unit 1 20 22 Foundry Road Seven...

Страница 2: ...BEFORE OPERATING Please pass these instructions on to the owner of this equipment V310 1 25HP V390 1 75HP V480 2 25 HP DANGER HAZARDOUS SUCTION Do not block water entry into filtration system with an...

Страница 3: ...rical equipment is in good condition Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage is discovered Do not add chemicals directly to the pool skimmer Adding und...

Страница 4: ...pool and spa pump is thoroughly water tested against flow pressure voltage current and mechanical performance parameters OASIS S advanced pump technology provides reliable and efficient performance t...

Страница 5: ...OTECTION It is recommended that the pump be protected from the weather Enclosures should be ventilated to allow a free flow of air for the fan cooled motor POWER CONNECTION OASIS pool and spa pumps ar...

Страница 6: ...tlet piping from the pump should be connected to the inlet connection on the swimming pool filter at the filter valve For pump installations above water level it generally requires a check valve in th...

Страница 7: ...et lid and filling the strainer basket area with water Replace the lid ensuring that it seals on the large o ring 2 Connect to the power supply and switch on 3 Allow the pump to run so that any air tr...

Страница 8: ...ATION AND OPERATION MANUAL info oasisaquatics com au oasisaquatics com au 8 FACTORY SETTING SPEEDS STAR RATINGS V310 7 Star Low 1600 Medium 2400 High 2850 V390 7 Star Low 1450 Medium 2400 High 2850 V4...

Страница 9: ...ncrease the speed setting This setting is not recommend to be used with a suction cleaner but may work 2 Med This should be used for gentle spa jet action and the majority of suction cleaners when con...

Страница 10: ...d to a skimmer box 3 High This should be used for backwashing manual vacuuming of the pool spa jets infloor cleaning and or water features PLEASE NOTE The V SERIES V390 will always run at high speed f...

Страница 11: ...t pot strainer basket lid anti clockwise and remove 3 Remove the hair and lint pot strainer basket by lifting upwards from its housing 4 Empty the trapped refuse from the basket Hose out with water if...

Страница 12: ...entre at the address indicated in this manual If the pump runs but there is no water flow or water flow is reduced the following condition may apply 1 The filter requires backwashing or it is blocked...

Страница 13: ...it has been damaged 5 Mains Over Voltage The Mains voltage has risen above 269 volts AC 6 Output Shaft Seized Motor failed to start Motor was stopped 7 Self Check One or more of the self tests failed...

Страница 14: ...from the date of purchase Oasis assumes no liability for consequential damages of any kind PLEASE NOTE This literature is not a complete guide to product usage Further information is available from yo...

Страница 15: ...o any of the following Improper chemical balance in the water Incorrect power supply and or connection Water damage from external sources Cement pebbles render or other pool surface finish blocking th...

Страница 16: ...TION MANUAL info oasisaquatics com au oasisaquatics com au 16 A part of the group Victoria 62 Parkhurst Drive Knoxfield VIC 3180 Australia New South Wales Unit 1 20 22 Foundry Road Seven Hills NSW 214...

Отзывы: