IMPORTANT WARNINGS & SAFETY INSTRUCTIONS 

IMPORTANT WARNINGS 

This  manual  contains  important  information  about  the  installation,  operation  and  safe  use  of  this 
product. This information should be given to the owner and/or operator of this equipment.  

When  installing  and  using  this  electrical  equipment,  basic  safety  precautions  should  always  be 
followed. Failure to follow safety warnings and instructions in this manual can result in serious injury 
and/or damage to your equipment. Read and follow all warning notices and instructions which are 
included in this manual. 

The Power Supply internally contains live components. There is a danger of electric shock if opened. 
If the power cord is damaged then it should be replaced by the manufacturer, their agent or similar. 

To reduce the risk of injury, 

DO NOT 

 permit young children to use this product unless they have 

been trained by the person responsible for their safety and they acknowledge their ability to use such 
equipment. To reduce the risk of accidents or incidents, service on the unit should only be performed 
by your local pool Professional. 

Ideally, as with all pool equipment, the controller should be installed out of direct weather. The service 
life of the 

Oasis SmartChem 

will be longer if it is not exposed to direct sunlight and rain. 

Before installing, and turning on the 

Oasis SmartChem 

system, take a sample of your Pool/Spa 

water to a pool store and have it tested to ensure that the Pool/Spa system is properly balanced. 
See below for recommended pool chemical ranges; 

CHLORINE: 1 - 3ppm   

pH 7.2 - 7.8 

TOTAL ALKALINITY: 80 - 150 mg/L 

 

CALCIUM HARDNESS: 90 - 300 mg/L 

PHOSPHATE FREE: (0) 

TOTAL DISOLVED SOLIDS: Below 1500ppm 

Always  take  a  sample  of  your  pool  water  away  from  the  return  jets  to  ensure  as  accurate 
reading as possible. 

Always  store  Pool  Chemicals  in  a  well-ventilated  position,  at  least  1.8M  away  from  your  pool 
equipment to prevent fume build-up and causing corrosion of your pool equipment. 

When mixing acid with water, ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO ACID. If 
you add water to acid, it will violently react (creating heat and boiling) and you may be splashed with 
acid. Wear protective equipment such as Gloves and Face Shield when diluting the acid. 

Only use diluted Acid, never use concentrated Acid. ACID should be diluted with water within the 
range of 1 part Acid to 1 part Water (1:1) to 1 part Acid to 2 parts Water (1:2). Dilute the acid in a 
well ventilate area and have running water ready. In case of spillage, wash down area immediately. 
Always seek medical advice if breathing is affected or an Acid Burn occurs. 

NEVER MIX CHEMICALS. Store your pool chemicals in containers that are visibly different by either 
colour and or size. Poisonous Gas can be produced if you mix chemicals. Always store chemicals 
in accordance to the relevant Dangerous Goods Codes and Standards. 

It  is  highly  recommended  that  you  check  your  Water  Chemistry  (especially  the  pH  and  Chlorine 
levels)  regularly,  either  with  a  quality  test  kit  or  at  your  local  pool  store  to  ensure  that  the 

Oasis 

SmartChem 

is working correctly, to ensure there are no malfunctions, and to ensure that the pH and 

ORP sensors are reading correctly. 

It  is  highly  recommended  that  before  you  install  the 

Oasis  SmartChem 

system,  that  you  sit  the 

probe/s in your pool water for 24hrs. This will help the probes to give a more accurate reading from 
the time of installation and will help with the longevity of the probes.

 

 

 

Содержание SmartChem

Страница 1: ......

Страница 2: ...2 GENERAL OVERVIEW 3 3 INSTALLATION 4 Mounting 4 Installation Diagram 4 Base Plate 6 Controller Connection 8 App Setup 9 4 ANCILLARY INSTRUCTIONS 13 Maintenance Schedule 13 Probe Cleaning 14 Replacin...

Страница 3: ...L CALCIUM HARDNESS 90 300 mg L PHOSPHATE FREE 0 TOTAL DISOLVED SOLIDS Below 1500ppm Always take a sample of your pool water away from the return jets to ensure as accurate reading as possible Always s...

Страница 4: ...m will automatically dose Pool acid when it is required to maintain the set pH level The Oasis SmartChem will also maintain the systems ORP by either turning the Chlorinator On or Off or by automatica...

Страница 5: ...red if installing into 40mm pipe for the sensors to mount into the centre of the inputs will be drilled out to accommodate the sensor probes A power cable providing power to the Oasis SmartChem from a...

Страница 6: ...or a period of time to ensure the glue used to connect the manifolds has had the appropriate time to dry and bond properly to achieve correct pressure rating The Sensor Injection Manifolds suit 50mm p...

Страница 7: ...Soak the ends of supply and injection hoses in hot water for 30 seconds to soften them this will make it easier when fitting the tubes to the pump barbs The lid kit has been installed into the bottle...

Страница 8: ...piping from the breather port on the lid to outside of the shed or shelter A through shed connection is supplied to prevent a build up of fumes inside the shed shelter ENSURE THAT THE OASIS SMART CON...

Страница 9: ...to be utilised through the App go to page 7 Of this guide and you can exit the menu by pressing the Menu button or if you need to reset the Oasis SmartChem unit press Enter and see below for further i...

Страница 10: ...first going into the Chemical Setup menu option first Chemical Setup When you go into the Chemical Setup option in the menu you will see this display The first thing that you will need to do is tell t...

Страница 11: ...problem with the pump you are changing over the acid bottle tub or if you have run out of Acid The same functionality applies to the ORP Sensor The Offset will allow you to adjust the reading of the p...

Страница 12: ...nd count to let you know how much time is left for the priming cycle The following is displayed on the App Home Screen There is only a limited amount of information displayed in regards to the Chemica...

Страница 13: ...is displaying CHECK you will need to take a sample of your pool water to your local pool shop and get it tested and add the amount of Acid or Buffer required to get the pH level back to where it needs...

Страница 14: ...page 8 of this manual Check all tubes fittings and connections to ensure no leaks Check the squeeze tube in the Peristaltic pump to ensure that it isn t leaking replace if doing so Apply a silicon lu...

Страница 15: ...uted on a soft cloth Clean the pH membrane rinse with water and condition in 20 KCl before use In the case of protein contamination use 5 Pepsin in 0 1M HCl solution HINT Calibrate the pH probe regula...

Страница 16: ...gently but firmly lift the cover The head cover will come off to expose the squeeze tube and the head The pump head can be pulled out the squeeze tube will come with it and a new squeeze tube can be...

Страница 17: ...rectly Clean and or Re calibrate probe or adjust probe Offset as per pg 8 pH Set Point is set to High Adjust pH Set Point to appropriate level 7 2 7 8 Manual Overdosing of Chlorine Shock Treatment Mai...

Страница 18: ...ppropriate level 30 50mg L As per above Note The need to run Stabiliser in an outdoor pool may be reduced if your Chlorinator is sufficiently sized to produce enough chlorine to negate the use of Stab...

Страница 19: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 18 of 22...

Страница 20: ...c to 14 strongly alkaline but any reading outside of the 5 5 to 8 5 range will only be displayed in the Chemical Setup option of the menu ORP readings on the home screen of the Oasis Smart App will on...

Страница 21: ...e interval of time for the added chemicals to properly mix throughout the pool system Continue testing and adding chemicals until the pool system becomes balanced o If you add large quantities of chem...

Страница 22: ...breach of a condition or warranty shall be limited to replacing or acquiring the equipment or part thereof where the same has been supplied The maximum liability incurred by the manufacturer shall no...

Страница 23: ...subject s Its use is beyond the control of the author contributor publishers and distributors and should not be relied upon without consulting your local Professional for comprehensive advice This gui...

Страница 24: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 23 of 22 9 NOTES...

Страница 25: ...eld VIC 3180 Australia T 03 9887 2131 New South Wales Unit 2 10 Boden Road Seven Hills NSW 2147 Australia T 02 9838 0000 Queensland Unit 4 8 Reichert Drive Molendinar QLD 4214 Australia T 07 5679 6821...

Отзывы: