Technical data
Nominal input voltage (primary voltage)
1)
100-240V AC
10 %
Nominal input current (primary current intake)
1)
max. 4.1 A
Nominal input frequency
50/60 Hz
Nominal output voltage (secondary voltage)
1)
25 V DC
3 %
Nominal output current (maximum secondary current)
1)
(per output)
max. 3.2 A
Rated capacity
1)
per output
max. 80 W (Class 2)
Rated capacity
1)
total
max. 240 W
Efficiency
92 %
Residual ripple
1 % (U
pp
250 mV)
Starting current
max. 15 A for 4 ms
Reset duration after triggering of the overload protection
5 minutes
Protection class
IP 68
Isolation between the primary/secondary side
galvanic
Maximum submersion depth
13.1 ft (4 m)
Length of power cable
20 ft (6 m)
Permissible water temperature
(operation in water, product active)
39 °F …95 °F
+ 4 °C …+ 35 °C
Permissible ambient temperature
(operation outside the water, product active)
14 °F …104 °F
- 10 °C …+ 40 °C
Storage temperature (product inactive = disconnected from the power
supply)
- 4 °F …158 °F
- 20 °C …+ 70 °C
Standard
UL 1310 / CSA C22.2 No. 223
Dimensions (length × width × height)
10.24 inch x 6.38 inch x 3.03 inch (260 mm × 162 mm × 77 mm)
Weight
10.6 lbs. (4.8 kg)
Article number
40289
1)
The values were determined after an operating time of 15 minutes and at an ambient temperature of 68 °F (+ 20 °C)
OASE connection cable
The maximum admissible current of the connection cable depends on the length of the cable.
Type
Length (Order No.)
Conductor cross section
Maximum admissible current
Connection cable
24 V DC/01
3.28 ft (1 m) (12762)
9.84 ft (3 m) (12552)
24.60 ft (7.5 m) (12375)
49.21 ft (15 m) (11740)
0.078 × 0.098 inch²
2 × 2.5 mm²
Output voltage
10 A
7.5 A
5 A
Max. cable length
49.21 ft
15 m
65.61 ft
20 m
98.42 ft
30 m
Symbols on the unit
Read the instructions for use.
Protect from direct sun radiation.
Dust-tight. Watertight to a depth of 13.1 ft (4 m).