INFORMATION ABOUT THIS 
OPERATING MANUAL 

Welcome to OASE Living Water. You 
made a good choice with the purchase of 
this product 

ProMax MudDrain 

7000/11000/14000

Prior to commissioning the unit, please 
read the instructions of use carefully and 
fully familiarise yourself with the unit. En-
sure that all work on and with this unit is 
only carried out in accordance with these 
instructions. 
Adhere to the safety information for the 
correct and safe use of the unit. 
Keep these instructions in a safe place! 
Please also hand over the instructions 
when passing the unit on to a new owner. 

 

Symbols used in these instructions 

Warnings 

The warning information is categorised by 
signal words, which indicate the extent of 
the hazard. 

 

 

W A R N I N G  

 

Indicates a possibly hazardous situa-
tion. 

 

Non-observance may lead to death or 
serious injuries. 

 

 

N O T E  

Indicates information intended to give the 
user a better understanding. 

 

Additional information 

 A  Reference to a figure, e.g. Fig. A. 

 

Reference to another section. 

 

PRODUCT DESCRIPTION 

Overview 

 

A ProMax Mud Drain 

7000/11000/14000 

1 Handle, 

adjustable 

2 Pump 

base 

3 Float 

switch 

Connection, pressure side, G1½ 

Power connection cable 

Stepped hose adapter 

 
 

Intended use 

ProMax MudDrain 7000/11000/14000, re-
ferred to in the following as "unit", may 
only be used as specified in the following: 

 

For pumping clear water or rain water. 

 

For pumping dirty water and max. 
30

mm large particles. 

 

For irrigating and watering. 

 

For transferring water from and draining 
basins such as swimming pools. 

 

Extraction of water from a well. 
–  Only for irrigation and watering pur-

poses! 

 

For pumping the water out of water 
butts/rain barrels or cisterns. 

 

Operation under observance of the 
technical data. 

 

Possible incorrect use 

The following restrictions apply to the unit: 

 

Not suitable for salt water. 

 

Not suitable for drinking water. 

 

Do not use for long-term operation (e.g. 
continuous recirculation of the water in 
a pond). 

 

Do not use for commercial or industrial 
purposes. 

 

Do not use in conjunction with chemi-
cals, foodstuff, easily flammable or ex-
plosive substances. 

 

Do not connect to the drinking water 
supply. 

Содержание promax cleardrain 14000

Страница 1: ...ProMax MudDrain 7000 11000 14000 ...

Страница 2: ...2 ProMax MudDrain 7000 11000 14000 A POX0008 B POX0013 C D POX0010 POX0011 ...

Страница 3: ... 3 E POX0009 ...

Страница 4: ... Additional information A Reference to a figure e g Fig A Reference to another section PRODUCT DESCRIPTION Overview A ProMax Mud Drain 7000 11000 14000 1 Handle adjustable 2 Pump base 3 Float switch 4 Connection pressure side G1 5 Power connection cable 6 Stepped hose adapter Intended use ProMax MudDrain 7000 11000 14000 re ferred to in the following as unit may only be used as specified in the fo...

Страница 5: ...e Only plug the unit into a correctly fitted socket Safe operation Dangerous electrical voltage Possible death or severe injury from electrocu tion Before reaching into the water al ways switch off and disconnect isolate all units located in the water with a volt age of 12 V AC or 30 V DC and se cure them from being switched on again Only operate the unit if no persons are in the water Never opera...

Страница 6: ...s function ensure that the length of cable between the float switch and the cable clip measures at least 10 cm N O T E The minimum residual water height is only reached in manual mode Manual mode The pump remains permanently switched on if the float switch is set vertically and the cable points downward N O T E The pump can run dry in manual mode Switch off the pump when the minimum water level is...

Страница 7: ...se this will impair the operat ing life of the unit accordingly N O T E Rinse the pump with clean water after use REMEDY OF FAULTS Malfunction Cause Remedy Pump does not start Power supply interrupted Check the fuse and electri cal plug connections Pump switches off after a short running period Overload protection has switched the pump off due to overheating Clean the intake and pressure hose Allo...

Страница 8: ...and chlorine free household cleaning agent After cleaning thoroughly rinse all parts in clean water WEAR PARTS Wear parts are excluded from the war ranty The following components are wear parts and may only be replaced by the OASE Service Impeller STORAGE OVER WINTERING The unit is not frost proof and has to be removed and put into storage if minus temperatures are expected How to correctly store ...

Страница 9: ...tion pressure side G1 G1 G1 Minimum switch on height maximum switch off height mm 500 250 530 270 530 270 Maximum switch on height minimum switch off height mm 670 120 700 100 700 100 Flow rate max l h 7500 11500 14500 Head height max m 5 7 11 Immersion depth max m 7 7 7 Particle size max mm 30 30 30 Power connection cable Length m 10 10 10 Dimensions Length mm 193 193 193 Width mm 247 247 247 Hei...

Страница 10: ...POX0039 ...

Отзывы: